Performance characteristics of a low volume spray chamber with a micro-flow nebulizer for ICP-MS

被引:22
作者
Cairns, WRL
Barbante, C
Capodaglio, G
Cescon, P
Gambaro, A
Eastgate, A
机构
[1] CNR, Ist Dinam Proc Ambientali, I-30123 Venice, Italy
[2] Univ Venice, Dipartimento Sci Ambientali, I-30123 Venice, Italy
[3] ePond SA, Dept Res & Dev, CH-1800 Vevey 1, Switzerland
关键词
D O I
10.1039/b314255h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Inspired by the original work of Todoli et al. in designing a torch integrated sample introduction system (TISIS) for ICP-AES, the authors have modified this design for use with ICP-MS, A microflow concentric nebuliser has been coupled with a single pass low volume spray chamber that can be clipped directly onto the base of a standard ICP-MS torch. The memory effects are very low: a 10 mug l(-1) tune solution containing Co, Ce and Tl was found to have washed out within 4 s. Matrix effects were reduced significantly across the mass range for a 10-fold diluted sea-water sample, with the signal being suppressed by only 10-20% compared with the response in ultra-pure water; detection limits were found to be higher than with the normal set up, with the instrument tuned to "robust" conditions.. Finally, it was shown that the low dead volume and low flow rate. meant that transient signals could be acquired easily, by flow injecting 100 mul of a standard and obtaining a flat topped peak with a 50 s signal plateau.
引用
收藏
页码:286 / 291
页数:6
相关论文
共 15 条
[1]   A large bore-direct injection high efficiency nebulizer for inductively coupled plasma spectrometry [J].
Acon, BW ;
McLean, JA ;
Montaser, A .
ANALYTICAL CHEMISTRY, 2000, 72 (08) :1885-1893
[3]   FLOW-INJECTION ANALYSIS WITH INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION-SPECTROSCOPY - CRITICAL COMPARISON OF CONVENTIONAL PNEUMATIC, ULTRASONIC AND DIRECT INJECTION NEBULIZATION [J].
LAFRENIERE, KE ;
RICE, GW ;
FASSEL, VA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1985, 40 (10-12) :1495-1504
[4]  
LAWRENCE KE, 1984, ANAL CHEM, V56, P292
[5]  
MCCURDY E, 2001, SPECTROSCOPY EUROPE, V13, P14
[6]   A direct injection high-efficiency nebulizer for inductively coupled plasma mass spectrometry [J].
McLean, JA ;
Zhang, H ;
Montaser, A .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :1012-1020
[7]   Revisitation of the matrix effects in inductively coupled plasma atomic emission spectrometry: the key role of the spray chamber - Invited lecture [J].
Mermet, JM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (05) :419-422
[8]  
Sturgeon R. E., 1998, NASS5 CRM NAT RES CO
[9]   Comparison of characteristics and limits of detection of pneumatic micronebulizers and a conventional nebulizer operating at low uptake rates in ICP-AES -: Invited lecture [J].
Todolí, JL ;
Hernandis, V .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) :1289-1295
[10]   Optimization of the evaporation cavity in a torch integrated sample introduction system based ICP-AES system.: Applications to matrix and transient effects, analysis of microsamples and analysis of certified solid samples [J].
Todolí, JL ;
Mermet, JM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (10) :1185-1191