Metal versus polyethylene wear particles in total hip replacements

被引:79
作者
Doorn, PF [1 ]
Campbell, PA [1 ]
Amstutz, HC [1 ]
机构
[1] ORTHOPED HOSP, JOINT REPLACEMENT INST, LOS ANGELES, CA 90007 USA
关键词
D O I
10.1097/00003086-199608001-00018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Research has recently been focused on the development of hip replacements with alternative bearing surfaces with cobalt chrome alloy, to avoid the production of polyethylene wear particles in hip replacements and polyethylene wear debris mediated bone lysis, Cobalt chrome on cobalt chrome bearing surfaces are being reevaluated. Characterization of wear particles and studies on the reaction of the body to these particles, have played an important role in the determination of the factors that cause aseptic loosening and will therefore play an important role in the comparison of metal on polyethylene and metal on metal hip prostheses, In this paper, a comparison between the different aspects of metal and polyethylene wear particles is made using data from the literature and the authors' experience. The authors conclude that techniques need to be optimized to isolate and characterize individual metal wear particles from periprosthetic tissues and they advocate the performance of in vitro studies with these in vivo generated wear particles or comparable particles.
引用
收藏
页码:S206 / S216
页数:11
相关论文
共 64 条
[1]  
[Anonymous], 1992, SOCIOLOGICA, V7
[2]   RESORPTION OF BONE BY INFLAMMATORY CELLS DERIVED FROM THE JOINT CAPSULE OF HIP ARTHROPLASTIES [J].
ATHANASOU, NA ;
QUINN, J ;
BULSTRODE, CJK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (01) :57-62
[3]  
BENZ EB, 1994, ORTH RES SOC 40 ANN
[4]   SENSITIVITY TO METAL AS A POSSIBLE CAUSE OF STERILE LOOSENING AFTER COBALT-CHROMIUM TOTAL HIP-REPLACEMENT ARTHROPLASTY [J].
BROWN, GC ;
LOCKSHIN, MD ;
SALVATI, EA ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (02) :164-168
[5]   TISSUE DIGESTION FOR WEAR DEBRIS PARTICLE ISOLATION [J].
CAMPBELL, P ;
MA, S ;
SCHMALZRIED, T ;
AMSTUTZ, HC .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (04) :523-526
[6]   ISOLATION OF PREDOMINANTLY SUBMICRON-SIZED UHMWPE WEAR PARTICLES FROM PERIPROSTHETIC TISSUES [J].
CAMPBELL, P ;
MA, S ;
YEOM, B ;
MCKELLOP, H ;
SCHMALZRIED, TP ;
AMSTUTZ, HC .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (01) :127-131
[7]  
CAMPBELL P, 1996, IN PRESS J ENG MED
[8]  
CAMPBELL P, 1993, T SOC BIOM BIRM AL A, P494
[9]   WIDESPREAD DISSEMINATION OF METAL DEBRIS FROM IMPLANTS [J].
CASE, CP ;
LANGKAMER, VG ;
JAMES, C ;
PALMER, MR ;
KEMP, AJ ;
HEAP, PF ;
SOLOMON, L .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (05) :701-712
[10]  
CLARKE IC, 1990, IMPLANT BONE INTERFA, P123