Heat transfer modelling in a ventilated cavity loaded with food product: Application to a refrigerated vehicle

被引:49
作者
Hoang, M. H. [1 ]
Laguerre, O. [1 ]
Moureh, J. [1 ]
Flick, D. [2 ]
机构
[1] Irstea, Refrigerat Proc Engn, F-92761 Antony, France
[2] AgroParisTech, UMR Genie Ind Alimentaire 1445, F-91300 Massy, France
关键词
Refrigerated vehicle; Heat transfer; Load temperature; AIR-FLOW; POROUS BOXES; PALLETS; SIMULATIONS;
D O I
10.1016/j.jfoodeng.2012.06.020
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A simplified heat transfer model of a refrigerated vehicle was developed in which two loads (front and rear) are considered. The front load located near the supply air duct is subjected to higher air velocity and lower air temperatures compared with the rear load, leading to product temperature heterogeneity. The model takes into account heat transfer by convection between the internal air and the load, between the external air and the walls of vehicle and by conduction in these walls. Air infiltration during door openings is also considered. Model validation was carried out by comparing the calculated product temperatures with those obtained from transport of fruits and frozen foods in a semi-trailer. Good agreement between the experimental and calculated results was obtained. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:389 / 398
页数:10
相关论文
共 23 条
[1]  
Bennahmias R., 1984, RAPPORT ESSAIS EFFEC
[2]  
Churi A., 2004, CELLULE ISOTHERME MA
[3]   Thermal performance indicators for refrigerated road vehicles [J].
Estrada-Flores, Silvia ;
Eddy, Andrew .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (06) :889-898
[4]   Experimental verification of analytical and CFD predictions of infiltration through cold store entrances [J].
Foster, AM ;
Swain, MJ ;
Barrett, R ;
James, ST .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (08) :918-925
[5]  
Gosney W.B., 1975, Proceedings of the Institute of Refrigeration, P31
[6]  
Guilpart J., 2003, TRANSPORT FRIGORIFIQ
[7]  
IIR, 1971, REC COND COLD STOR P
[8]   Heat transfer modelling in a refrigerated display cabinet: The influence of operating conditions [J].
Laguerre, O. ;
Hoang, M. H. ;
Flick, D. .
JOURNAL OF FOOD ENGINEERING, 2012, 108 (02) :353-364
[9]   Temperature prediction in domestic refrigerators: Deterministic and stochastic approaches [J].
Laquerre, O. ;
Flick, D. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2010, 33 (01) :41-51
[10]  
Meffert H. F. T. H., 1983, 16 INT C REFR IIF II, P466