Nontargeted Quantitation of Lipid Classes Using Hydrophilic Interaction Liquid Chromatography-Electrospray Ionization Mass Spectrometry with Single Internal Standard and Response Factor Approach

被引:121
作者
Cifkova, Eva [1 ]
Holcapek, Michal [1 ]
Lisa, Miroslav [1 ]
Ovcacikova, Magdalena [1 ]
Lycka, Antonin [2 ,3 ]
Lynen, Frederic [4 ]
Sandra, Pat [5 ]
机构
[1] Univ Pardubice, Dept Analyt Chem, Fac Chem Technol, Pardubice 53210, Czech Republic
[2] Res Inst Organ Synth, Pardubice 53354, Czech Republic
[3] Univ Hradec Kralove, Fac Sci, Hradec Kralove 50003 3, Czech Republic
[4] Univ Ghent, Dept Organ Chem, B-9000 Ghent, Belgium
[5] Res Inst Chromatog, B-8500 Kortrijk, Belgium
关键词
THIN-LAYER-CHROMATOGRAPHY; TRIPLE QUADRUPOLE; PHASE SEPARATION; HUMAN PLASMA; FATTY-ACID; SILVER-ION; PHOSPHOLIPIDS; MATRIX; TRIACYLGLYCEROLS; IDENTIFICATION;
D O I
10.1021/ac3024476
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
The identification and quantitation of a wide range of lipids in complex biological samples is an essential requirement for the lipidomic studies. High-performance liquid chromatography mass spectrometry (HPLC/MS) has the highest potential to obtain detailed information on the whole lipidome, but the reliable quantitation of multiple lipid classes is still a challenging task. In this work, we describe a new method for the nontargeted quantitation of polar lipid classes separated by hydrophilic interaction liquid chromatography (HILIC) followed by positive-ion electrospray ionization mass spectrometry (ESI-MS) using a single internal lipid standard to which all class specific response factors (RFs) are related to. The developed method enables the nontargeted quantitation of lipid classes and molecules inside these classes in contrast to the conventional targeted quantitation, which is based on predefined selected reaction monitoring (SRM) transitions for selected lipids only. In the nontargeted quantitation method described here, concentrations of lipid classes are obtained by the peak integration in HILIC chromatograms multiplied by their RFs related to the single internal standard (i.e., sphingosyl PE, d17:1/12:0) used as common reference for all polar lipid classes. The accuracy, reproducibility and robustness of the method have been checked by various means: (1) the comparison with conventional lipidomic quantitation using SRM scans on a triple quadrupole (QqQ) mass analyzer, (2) P-31 nuclear magnetic resonance (NMR) quantitation of the total lipid extract, (3) method robustness test using subsequent measurements by three different persons, (4) method transfer to different HPLC/MS systems using different chromatographic conditions, and (5) comparison with previously published results for identical samples, especially human reference plasma from the National Institute of Standards and Technology (NIST human plasma). Results on human plasma, egg yolk and porcine liver extracts are presented and discussed.
引用
收藏
页码:10064 / 10070
页数:7
相关论文
共 47 条
[1]
Quantitative profiling of phosphatidylcholine and phosphatidylethanolamine in a steatosis/fibrosis model of rat liver by nanoflow liquid chromatography/tandem mass spectrometry [J].
Ahn, Eun Jeong ;
Kim, Hanna ;
Chung, Bong Chul ;
Kong, Gu ;
Moon, Myeong Hee .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1194 (01) :96-102
[2]
Structural analysis of phosphatidylcholines by post-source decay matrix-assisted laser desorption/ionization time-of-flight mass spectrometry [J].
Al-Saad, KA ;
Siems, WF ;
Hill, HH ;
Zabrouskov, V ;
Knowles, NR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (04) :373-382
[3]
Axelsen PH, 2010, J LIPID RES, V51, P660, DOI [10.1194/jlr.d001750, 10.1194/jlr.D001750]
[4]
Identification and quantification of phosphatidylcholines containing very-long-chain polyunsaturated fatty acid in bovine and human retina using liquid chromatography/tandem mass spectrometry [J].
Berdeaux, Olivier ;
Juaneda, Pierre ;
Martine, Lucy ;
Cabaret, Stephanie ;
Bretillon, Lionel ;
Acar, Niyazi .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (49) :7738-7748
[5]
BLIGH EG, 1959, CAN J BIOCHEM PHYS, V37, P911
[6]
Liquid chromatography-atmospheric pressure photoionization-mass spectrometry analysis of triacylglycerol lipids - Effects of mobile phases on sensitivity [J].
Cai, Sheng-Suan ;
Short, Luke Chandler ;
Syage, Jack A. ;
Potvin, Michael ;
Curtis, Jonathan M. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1173 (1-2) :88-97
[7]
Analysis of triacylglycerols in fat body of bumblebees by chromatographic methods [J].
Cvacka, J ;
Hovorka, O ;
Jiros, P ;
Kindl, J ;
Stránsky, K ;
Valterová, I .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1101 (1-2) :226-237
[8]
Matrix-assisted laser desorption/ionization analysis of lipids and high molecular weight hydrocarbons with lithium 2,5-dihydroxybenzoate matrix [J].
Cvacka, J ;
Svatos, A .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (19) :2203-2207
[9]
A comprehensive classification system for lipids [J].
Fahy, E ;
Subramaniam, S ;
Brown, HA ;
Glass, CK ;
Merrill, AH ;
Murphy, RC ;
Raetz, CRH ;
Russell, DW ;
Seyama, Y ;
Shaw, W ;
Shimizu, T ;
Spener, F ;
van Meer, G ;
VanNieuwenhze, MS ;
White, SH ;
Witztum, JL ;
Dennis, EA .
JOURNAL OF LIPID RESEARCH, 2005, 46 (05) :839-861
[10]
A comprehensive method for lipid profiling by liquid chromatography-ion cyclotron resonance mass spectrometry [J].
Fauland, Alexander ;
Koefeler, Harald ;
Troetzmueller, Martin ;
Knopf, Astrid ;
Hartler, Juergen ;
Eberl, Anita ;
Chitraju, Chandramohan ;
Lankmayr, Ernst ;
Spener, Friedrich .
JOURNAL OF LIPID RESEARCH, 2011, 52 (12) :2314-2322