Analysis of biological wastewater treatment processes using multicomponent gas phase mass balancing

被引:25
作者
Gapes, D [1 ]
Keller, J [1 ]
机构
[1] Univ Queensland, Adv Wastewater Management Ctr, Brisbane, Qld 4072, Australia
关键词
mass spectrometry; off-gas analysis; respirometry; turbulence; oxygen uptake rate; wastewater treatment;
D O I
10.1002/bit.10097
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A reactor system using off-gas analysis was developed for analyzing wastewater treatment process reactions. Using a mass spectrometer for the gas analysis provides the ability to simultaneously measure several gas components (such as oxygen, nitrogen, carbon dioxide, and argon). One of the benefits of the reactor design was the precise control of the dissolved oxygen concentration, uncoupled from the system turbulence, which was controlled via a gas recycle loop. This feature allowed control of the turbulence within the reactor without any need for mechanical stirring. Using oxygen as the test gas, the reactor was shown to perform well in the measurement of oxygen uptake rate of nitrifying activated sludge. The oxygen uptake rate calculations were made using a simple calibration method developed for the reactor system. The reactor was able to provide precise and accurate results for this test case. Furthermore, the system was capable of measuring under dynamic process conditions, as well as when the process rates were constant (steady state). (C) 2001 John Wiley & Sons, Inc.
引用
收藏
页码:361 / 375
页数:15
相关论文
共 28 条
[1]   RESPIROMETRIC MEASUREMENTS ON ACTIVATED-SLUDGE [J].
BLOK, J .
WATER RESEARCH, 1974, 8 (01) :11-18
[2]  
Chisti Y, 1996, CHEM ENG RES DES, V74, P575
[3]   INFLUENCE OF FLUID VELOCITIES ON THE DEGRADATION OF VOLATILE AROMATIC-COMPOUNDS IN MEMBRANE-BOUND BIOFILMS [J].
DEBUS, O ;
BAUMGARTL, H ;
SEKOULOV, I .
WATER SCIENCE AND TECHNOLOGY, 1994, 29 (10-11) :253-262
[4]  
EYER A, 1995, BIOTECHNOL BIOENG, V5, P54
[5]   Novel calibration method for mass spectrometers for on-line gas analysis. Set-up for the monitoring of a bacterial fermentation [J].
Ferreira, BS ;
van Keulen, F ;
da Fonseca, MMR .
BIOPROCESS ENGINEERING, 1998, 19 (04) :289-296
[6]   DETERMINATION OF VOLUMETRIC OXYGEN-TRANSFER COEFFICIENT BY OFF-GAS ANALYSIS [J].
FUJIE, K ;
TSUCHIYA, K ;
FAN, LS .
JOURNAL OF FERMENTATION AND BIOENGINEERING, 1994, 77 (05) :522-527
[7]  
GALIL N, 1991, RES J WATER POLLUT C, V63, P768
[8]  
GAUDY AF, 1968, J WATER POLLUT CONTR, V40, pR129
[9]   PARTICLE-SIZE REDUCTION BY BREAKAGE IN BIOLOGICAL WASTEWATER-TREATMENT [J].
GLASGOW, LA ;
POLLOCK, RJ ;
BARKLEY, WA .
BIOTECHNOLOGY AND BIOENGINEERING, 1983, 25 (04) :901-918
[10]   Aeration investigation of biological aerated filters using off-gas analysis [J].
Harris, SL ;
Stephenson, T ;
Pearce, P .
WATER SCIENCE AND TECHNOLOGY, 1996, 34 (3-4) :307-314