Reliability of Navigated Lower Limb Alignment in High Tibial Osteotomies

被引:35
作者
Goleski, Patrick [1 ,2 ]
Warkentine, Blaine [1 ,3 ]
Lo, Darrick [1 ]
Gyuricza, Cassie [1 ]
Kendoff, Daniel [1 ,4 ]
Pearle, Andrew D. [1 ]
机构
[1] Hosp Special Surg, Dept Orthopaed, New York, NY 10021 USA
[2] Univ Michigan, Sch Med, Ann Arbor, MI USA
[3] BrainLAB USA, Chicago, IL USA
[4] Hannover Med Sch, Trauma Dept, D-3000 Hannover, Germany
关键词
navigation; high tibial osteotomy; reliability; accuracy; computer-assisted surgery;
D O I
10.1177/0363546508319314
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Navigation allows for determination of the mechanical axis of the lower extremity during high tibial osteotomy (HTO) procedures. The objectives of this study were to (1) evaluate the reliability of noninvasive registration with an image-free navigation system for HTO and (2) determine the accuracy of the navigation system to monitor changes in lower limb alignment as compared with alignment measured with a novel 3-dimensional computed tomography method. Hypothesis: Navigated limb alignment demonstrates good reliability and accuracy in all 3 planes. Study Design: Descriptive laboratory study. Methods: Thirteen cadaver legs were used to examine the intra- and interobserver registration reliability of 3 observers. Initial coronal, sagittal, and axial alignment was measured on 6 legs, 3 times each, at intervals > 36 hours. Navigated HTOs were then performed on all 13 legs, pre- and postoperative alignment was recorded, and data were compared with equivalent measures obtained by 3-dimensional computed tomography. Reliability and accuracy data were both analyzed using intraclass correlation coefficients with the following established thresholds: good, > 0.75; fair, 0.4 to 0.75; and poor, < 0.4. Results: Intraclass correlation coefficients for intraobserver reliability were categorized as follows: varus-valgus, good; flexion-extension, fair; and femoral-tibial rotation, poor. For interobserver reliability, results were varus-valgus, fair; flexion-extension, fair; and femoral-tibial rotation, poor. Intraclass correlation coefficients for navigation accuracy were varus-valgus, good; tibial slope, good; and tibial torsion, poor. Maximum differences in navigation-computed tomography measurements were Delta varus-valgus angle, 4.5 degrees; Delta tibial slope, 8.8 degrees; and Delta tibial torsion, 16.5 degrees. Conclusion and Clinical Relevance: Navigation may be reliable and clinically useful for dynamic monitoring of coronal leg alignment but has limits in determination of sagittal and axial plane alignment.
引用
收藏
页码:2179 / 2186
页数:8
相关论文
共 45 条
[1]
EVALUATION OF CT SCANS AND 3-D REFORMATTED IMAGES FOR QUANTITATIVE ASSESSMENT OF THE HIP [J].
ABEL, MF ;
SUTHERLAND, DH ;
WENGER, DR ;
MUBARAK, SJ .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1994, 14 (01) :48-53
[2]
Agneskirchner JD, 2007, AM J SPORT MED, V35, P494
[3]
The validation of 3D spiral CT-based measurements of simulated maxillofacial neoplasms [J].
Cavalcanti, MGP ;
Ruprecht, A ;
Bonomie, JM ;
Vannier, MW .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2000, 89 (06) :753-758
[4]
Craniofacial measurements based on 3D-CT volume rendering: implications for clinical applications [J].
Cavalcanti, MGP ;
Rocha, SS ;
Vannier, MW .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (03) :170-176
[5]
Three-dimensional computed tomography landmark measurement in craniofacial surgical planning: Experimental validation in vitro [J].
Cavalcanti, MGP ;
Haller, JW ;
Vannier, MW .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 57 (06) :690-694
[6]
Kinematic navigation in total knee replacement - Experience from the first 50 cases [J].
Chang, Chih-Wei ;
Yang, Chyun-Yu .
JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2006, 105 (06) :468-474
[7]
ENGEL GM, 1981, CLIN ORTHOP RELAT R, P137
[8]
ANATOMICAL DIFFERENCES IN FEMUR AND TIBIA BETWEEN NEGROIDS AND CAUCASOIDS AND THEIR EFFECTS UPON LOCOMOTION [J].
FARRALLY, MR ;
MOORE, WJ .
AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1975, 43 (01) :63-69
[9]
Fleiss J., 1986, Reliability of measurement: the design and analysis of clinical experiments
[10]
Diagnostic performance of CT, MPR and 3DCT imaging in maxillofacial trauma [J].
Fox, LA ;
Vannier, MW ;
West, OC ;
Wilson, AJ ;
Baran, GA ;
Pilgram, TK .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1995, 19 (05) :385-395