Modeling solar-driven ejector refrigeration system offering air conditioning for office buildings

被引:59
作者
Guo, J. [1 ]
Shen, H. G. [1 ]
机构
[1] Donghua Univ, Sch Environm Sci & Engn, Shanghai 201620, Peoples R China
关键词
Solar-driven ejector refrigeration; Lumped method; Dynamic model; COP; Solar fraction; PERFORMANCE;
D O I
10.1016/j.enbuild.2008.07.016
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A lumped method combined with dynamic model is proposed for use in investigating the performance and solar fraction of a solar-driven ejector refrigeration system (SERS) using R134a, for office air conditioning application for buildings in Shanghai, China. Classical hourly outdoor temperature and solar radiation model were used to provide basic data for accurate analysis of the system performance. Results indicate that during the office working-time, i.e., from 9:00 to 17:00, the average COP and the average solar fraction of the system were 0.48 and 0.82 respectively when the operating conditions were: generator temperature (85 degrees C), evaporator temperature (8 degrees C) and condenser temperature varying with ambient temperature. Compared with traditional compressor based air conditioner, the system can save upto 80% electric energy when providing the same cooling capacity for office buildings. Hence, the system offers a good energy conservation method for office buildings. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:175 / 181
页数:7
相关论文
共 19 条
[1]   A small capacity steam-ejector refrigerator: experimental investigation of a system using ejector with movable primary nozzle [J].
Aphornratana, S ;
Eames, IW .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1997, 20 (05) :352-358
[2]   Revisiting solar-powered ejector air conditioner - the greener the better [J].
Arbel, A ;
Sokolov, M .
SOLAR ENERGY, 2004, 77 (01) :57-66
[3]   Ejectors: applications in refrigeration technology [J].
Chunnanond, K ;
Aphornratana, S .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2004, 8 (02) :129-155
[4]   Results of an experimental study of an advanced jet-pump refrigerator operating with R245fa [J].
Eames, Ian W. ;
Ablwaifa, All E. ;
Petrenko, Volodymyr .
APPLIED THERMAL ENGINEERING, 2007, 27 (17-18) :2833-2840
[5]   Collector selection for solar ejector cooling system [J].
Huang, BJ ;
Petrenko, VA ;
Samofatov, IY ;
Shchetinina, NA .
SOLAR ENERGY, 2001, 71 (04) :269-274
[6]   A 1-D analysis of ejector performance [J].
Huang, BJ ;
Chang, JM ;
Wang, CP ;
Petrenko, VA .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1999, 22 (05) :354-364
[7]   THE INTERRELATIONSHIP AND CHARACTERISTIC DISTRIBUTION OF DIRECT, DIFFUSE AND TOTAL SOLAR RADIATION [J].
LIU, BYH ;
JORDAN, RC .
SOLAR ENERGY, 1960, 4 (03) :1-19
[8]  
MURTHY SS, 1991, RENEW ENERG, V1, P757
[9]  
*REFPROP, 1980, NIST STAND REF DAT 2
[10]   Design and parametric investigation of an ejector in an air-conditioning system [J].
Rogdakis, ED ;
Alexis, GK .
APPLIED THERMAL ENGINEERING, 2000, 20 (02) :213-226