Development of high-performance liquid chromatography and nonaqueous capillary electrophoresis methods for the separation of calixarene derivatives

被引:6
作者
Ding, Chenghua
Han, Po
Song, Juanmei
Liu, Hongxia [1 ]
Zhang, Shusheng
Ye, Baoxian
Wu, Yangjie
机构
[1] Zhengzhou Univ, Dept Chem, Key Lab Chem Biol & Organ Chem Henan, Zhengzhou 450052, Peoples R China
[2] Tsing Hua Univ, Grad Sch Shenzhen, Key Lab Chem Biol Guangdong, Shenzhen 518055, Peoples R China
基金
中国国家自然科学基金;
关键词
calixarene derivatives; high-performance liquid chromatography; nonaqueous capillary electrophoresis;
D O I
10.1016/j.aca.2006.03.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present work, the separations of calixarene derivatives have been investigated using both high-performance liquid chromatography (HPLC) and nonaqueous capillary electrophoresis (NACE) techniques. HPLC-1 method with LC-318 (pore size = 300 angstrom) column and MeCN mobile phase was optimized for the separation of calixarenes. At the flow-rate of 1 ml/min p-nitrocalix[6]arene, calix[4]arene and calix[6]arene could be well baseline and symmetrically separated within 5 min. For the separation of p-tert-butylcalix[n]arenes (n = 4, 6, 8), HPLC-2 and NACE methods have been optimized. The optimal conditions in HPLC-2 method included NH2, column and MeCN mobile phase, and p-tert-butylcalix[n]arenes (n =4, 6, 8) were baseline separated within 10 min at 0.8 min/min. The optimal conditions for NACE method employed MeCN-H2O (8:2, v/v) as the nonaqueous medium and 120 mM Tris/HCI (pH 9.0) as the buffer, and p-tert-butylcalix[n]arenes (n = 4, 6, 8) were successfully baseline resolved within 16 min. With the detection at 280 nm, the calibration lines were linear in the ranges of 1-200 mu g/ml for calixarene derivatives by HPLC-1 and HPLC-2 methods, and of 2.5-200 mu g/ml for p-tert-butylcalix[n]arenes (n = 4, 6, 8) by NACE method, respectively. The detection limits (S/N = 3) and recoveries ranged from 0.5 to 1.4 mu g/ml and from 98.1 to 102.4% by both HPLC-1 and HPLC-2 methods, and from 1.3 to 2.0 mu g/ml and from 97.9 to 105.1% by NACE method, respectively. The intra-day reproducibility of the methods was determined with satisfactory results. The proposed HPLC and NACE methods were accurate and reproducible, and could be utilized to separate and determine calixarene derivatives.(c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:246 / 252
页数:7
相关论文
共 37 条
[1]   Molecular recognition by a silica-bound fullerene derivative [J].
Bianco, A ;
Gasparrini, F ;
Maggini, M ;
Misiti, D ;
Polese, A ;
Prato, M ;
Scorrano, G ;
Toniolo, C ;
Villani, C .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (32) :7550-7554
[2]  
BOWER MT, 1998, TRENDS ANAL CHEM, V17, P424
[3]   Resolution of inherently chiral calix[4]arenes with AABB and CDCD substitution patterns on the upper and lower rims, respectively [J].
Caccamese, S ;
Bottino, A ;
Cunsolo, F ;
Parlato, S ;
Neri, P .
TETRAHEDRON-ASYMMETRY, 2000, 11 (15) :3103-3112
[4]   Inherently chiral α-picolyloxy-p-tert-butylcalix[5]arene crown ethers:: Synthesis, structure proof, and enantioselective HPLC resolution [J].
Caccamese, S ;
Notti, A ;
Pappalardo, S ;
Parisi, MF ;
Principato, G .
TETRAHEDRON, 1999, 55 (17) :5505-5514
[5]   Nonaqueous versus aqueous capillary electrophoresis for the dosage of N-butylscopolamine in various pharmaceutical formulations [J].
Cherkaoui, S ;
Mateus, L ;
Christen, P ;
Veuthey, JL .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 21 (01) :165-174
[6]  
DHAWAN B, 1987, MAKROMOL CHEM, V188, P921
[7]   Manufacturing planning and execution software interfaces [J].
Feng, SC .
JOURNAL OF MANUFACTURING SYSTEMS, 2000, 19 (01) :1-17
[8]   Comparison of supercritical fluid chromatographic and high-performance liquid chromatographic separations of p-tert-butylcalix[n]arenes [J].
Graham, BF ;
Harrowfield, JM ;
Trengove, RD ;
Rodriguez, I ;
Li, SFY .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1997, 35 (05) :232-236
[9]  
GUTSCHE CD, 1990, ORG SYNTH, V68, P238
[10]  
GUTSCHE CD, 1990, ORG SYNTH, V68, P234