A simple, robust hardware device for passive or active respiratory gating in MRI and MRS experiments

被引:25
作者
Garbow, JR [1 ]
Dugas, JP
Song, SK
Conradi, MS
机构
[1] Washington Univ, Dept Chem, St Louis, MO 63130 USA
[2] Washington Univ, Dept Radiol, St Louis, MO 63130 USA
[3] Washington Univ, Dept Phys, St Louis, MO 63130 USA
关键词
small-animal MRI; respiratory gating; hardware; ventilator;
D O I
10.1002/cmr.b.20010
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The synchronization of MR data collection with respiration is essential for collecting high-quality, in vivo magnetic resonance images and spectra of rodents. in this article, we describe the design and operation of a simple, robust device for respiratory gating. Inexpensive and easy to construct, the device operates in either free-breathing or actively driven (ventilator) modes. Respiration is monitored either by a pressure transducer connected to the nosecone used to deliver anesthesia to the animal or by a fiber-optic detector of the animal's motion. The device generates a TTL signal that can be used to trigger the MR scanner to enable respiratory-synchronized data acquisition. A variety of different MR imaging sequences can be easily modified to incorporate respiratory gating. We present respiratory-synchronized imaging and spectroscopy results obtained using this device, including H-1 MR images of mouse lung, liver, and spinal cord and localized H-1 spectra of mouse liver. (C) 2004 Wiley Periodicals, Inc.
引用
收藏
页码:40 / 48
页数:9
相关论文
共 29 条
[1]   RESPIRATORY EFFECTS IN TWO-DIMENSIONAL FOURIER-TRANSFORM MR IMAGING [J].
AXEL, L ;
SUMMERS, RM ;
KRESSEL, HY ;
CHARLES, C .
RADIOLOGY, 1986, 160 (03) :795-801
[2]   MR DIFFUSION TENSOR SPECTROSCOPY AND IMAGING [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
BIOPHYSICAL JOURNAL, 1994, 66 (01) :259-267
[3]  
Beckmann N, 2001, MAGNET RESON MED, V45, P88, DOI 10.1002/1522-2594(200101)45:1<88::AID-MRM1013>3.0.CO
[4]  
2-N
[5]   SPATIAL LOCALIZATION IN NMR-SPECTROSCOPY INVIVO [J].
BOTTOMLEY, PA .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1987, 508 :333-348
[6]   Dynamic, contrast-enhanced perfusion MRI in mouse gliomas: Correlation with histopathology [J].
Cha, S ;
Johnson, G ;
Wadghiri, YZ ;
Jin, O ;
Babb, J ;
Zagzag, D ;
Turnbull, DH .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (05) :848-855
[7]   MAGNETIC-RESONANCE IMAGING WITH RESPIRATORY GATING - TECHNIQUES AND ADVANTAGES [J].
EHMAN, RL ;
MCNAMARA, MT ;
PALLACK, M ;
HRICAK, H ;
HIGGINS, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) :1175-1182
[8]   In vivo H-1-NMR microimaging with respiratory triggering for monitoring adoptive immunotherapy of metastatic mouse lymphoma [J].
Fichtner, KP ;
Schirrmacher, V ;
Griesbach, A ;
Hull, WE .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) :440-455
[9]   The lever-coil: a simple, inexpensive sensor for respiratory and cardiac motion in MRI experiments [J].
Fishbein, KW ;
McConville, P ;
Spencer, RGS .
MAGNETIC RESONANCE IMAGING, 2001, 19 (06) :881-889
[10]  
GARBOW J, 2003, IEEE S BIOINF BIOENG, V3, P126