Pulmonary vein isolation: Comparison of bipolar and unipolar electrograms at successful and unsuccessful ostial ablation sites

被引:36
作者
Tada, H [1 ]
Oral, H [1 ]
Wasmer, K [1 ]
Greenstein, R [1 ]
Pelosi, F [1 ]
Knight, BP [1 ]
Strickberger, SA [1 ]
Morady, F [1 ]
机构
[1] Univ Michigan, Dept Internal Med, Div Cardiol, Ann Arbor, MI 48109 USA
关键词
atrial fibrillation; pulmonary vein; unipolar electrogram;
D O I
10.1046/j.1540-8167.2002.00013.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: No prior studies have quantitatively analyzed the characteristics of bipolar or unipolar electrograms that may be helpful in identifying successful ostial ablation sites in patients with atrial fibrillation undergoing segmental pulmonary vein isolation. Methods and Results: The characteristics of bipolar and unipolar electrograms recorded at 185 successful and 120 unsuccessful ostial pulmonary venous ablation sites were analyzed in 21 patients with atrial fibrillation. A decapolar Lasso catheter was positioned near the ostia of the pulmonary veins, and a conventional ablation catheter was used to deliver radiofrequency energy at individual ostial sites where pulmonary vein potentials were recorded. With both bipolar and unipolar recordings, the only timing parameter that distinguished successful from unsuccessful ostial ablation sites was the timing of the electrogram recorded by the ablation catheter relative to the earliest pulmonary vein potential recorded by the Lasso catheter. With both bipolar and unipolar recordings, electrograms demonstrated a larger amplitude at successful than at unsuccessful ablation sites. Unipolar electrograms had a steeper intrinsic deflection at successful than at unsuccessful ostial ablation sites. The morphologies of the unipolar electrograms recorded by the ablation catheter and by the contiguous electrode of the Lasso catheter usually were identical. Conclusion: In patients undergoing segmental isolation of the pulmonary veins, unipolar recordings provide more information than bipolar recordings helpful in distinguishing successful from unsuccessful ostial ablation sites. Furthermore, unipolar recordings, but not bipolar recordings, allow accurate localization of the position of the ablation catheter relative to the electrodes of the Lasso catheter.
引用
收藏
页码:13 / 19
页数:7
相关论文
共 11 条
[1]   ELECTROGRAM CRITERIA FOR IDENTIFICATION OF APPROPRIATE TARGET SITES FOR RADIOFREQUENCY CATHETER ABLATION OF ACCESSORY ATRIOVENTRICULAR CONNECTIONS [J].
CALKINS, H ;
KIM, YN ;
SCHMALTZ, S ;
SOUSA, J ;
ELATASSI, R ;
LEON, A ;
KADISH, A ;
LANGBERG, JJ ;
MORADY, F .
CIRCULATION, 1992, 85 (02) :565-573
[2]   Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins - Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation [J].
Chen, SA ;
Hsieh, MH ;
Tai, CT ;
Tsai, CF ;
Prakash, VS ;
Yu, WC ;
Hsu, TL ;
Ding, YA ;
Chang, MS .
CIRCULATION, 1999, 100 (18) :1879-1886
[3]  
De Bakker J., 1995, CARDIAC ELECTROPHYSI, P1068
[4]   Electrophysiological end point for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Garrigue, S ;
Takahashi, A ;
Lavergne, T ;
Hocini, M ;
Peng, JT ;
Roudaut, R ;
Clementy, J .
CIRCULATION, 2000, 101 (12) :1409-1417
[5]   Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Quiniou, G ;
Garrigue, S ;
Le Mouroux, A ;
Le Métayer, P ;
Clémenty, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) :659-666
[6]   Electrophysiological breakthroughs from the left atrium to the pulmonary veins [J].
Haïssaguerre, M ;
Shah, DC ;
Jaïs, P ;
Hocini, M ;
Yamane, T ;
Deisenhofer, I ;
Chauvin, M ;
Garrigue, S ;
Clémenty, J .
CIRCULATION, 2000, 102 (20) :2463-2465
[7]  
Hocini M, 2000, PACE, V23, P1832
[8]   Pulmonary vein electrogram characteristics in patients with focal sources of paroxysmal atrial fibrillation [J].
Hsieh, MH ;
Tai, CT ;
Tsai, CF ;
Yu, WC ;
Lee, SH ;
Lin, YK ;
Ding, YA ;
Chang, MS ;
Chen, SA .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (09) :953-959
[9]   JUNCTION BETWEEN LEFT ATRIUM AND PULMONARY VEINS - AN ANATOMIC STUDY OF HUMAN HEARTS [J].
NATHAN, H ;
ELIAKIM, M .
CIRCULATION, 1966, 34 (03) :412-&
[10]   EPICARDIAL MAPPING - HOW TO MEASURE LOCAL ACTIVATION [J].
PAUL, T ;
MOAK, JP ;
MORRIS, C ;
GARSON, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (03) :285-292