Application of a linear ion trap/orbitrap mass spectrometer in metabolite characterization studies: Examination of the human liver microsomal metabolism of the non-tricyclic anti-depressant nefazodone using data-dependent accurate mass measurements

被引:93
作者
Peterman, SM
Duczak, N
Kalgutkar, AS
Lame, ME
Soglia, JR
机构
[1] Pfizer Global Res & Dev, Pharmacokinet Dynam & Metab Dept, Groton, CT 06340 USA
[2] Thermo Electron Corp, Somerset, NJ USA
关键词
D O I
10.1016/j.jasms.2005.11.014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report herein, facile metabolite identification workflow on the anti-depressant nefazodone, which is derived from accurate mass measurements based on a single run/experimental analysis. A hybrid LTQ/orbitrap mass spectrometer was used to obtain accurate mass full scan MS and MS/MS in a data-dependent fashion to eliminate the reliance on a parent mass list. Initial screening utilized a high mass tolerance (similar to 10 ppm) to filter the full scan MS data for previously reported nefazodone metabolites. The tight mass tolerance reduces or eliminates background chemical noise, dramatically increasing sensitivity for confirming or eliminating the presence of metabolites as well as isobaric forms. The full scan accurate mass analysis of suspected metabolites can be confirmed or refuted using three primary tools: (1) predictive chemical formula and corresponding mass error analysis, (2) rings-plus-double bonds, and (3) accurate mass product ion spectra of parent and suspected metabolites. Accurate mass characterization of the parent ion structure provided the basis for assessing structural assignment for metabolites. Metabolites were also characterized using parent product ion m/z values to filter all tandem mass spectra for identification of precursor ions yielding similar product ions. Identified metabolite parent masses were subjected to chemical formula calculator based on accurate mass as well as bond saturation. Further analysis of potential nefazodone metabolites was executed using accurate mass product ion spectra. Reported mass measurement errors for all full scan MS and MS/MS spectra was < 3 ppm, regardless of relative ion abundance, which enabled the use of predictive software in determining product ion structure. The ability to conduct biotransformation profiling via tandem mass spectrometry coupled with accurate mass measurements, all in a single experimental run, is clearly one of the most attractive features of this methodology.
引用
收藏
页码:363 / 375
页数:13
相关论文
共 21 条
[1]   Increasing throughput and information content for in vitro drug metabolism experiments using ultra-performance liquid chromatography coupled to a quadrupole time-of-flight mass spectrometer [J].
Castro-Perez, J ;
Plumb, R ;
Granger, JH ;
Beattie, L ;
Joncour, K ;
Wright, A .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (06) :843-848
[2]   In vitro metabolism of ethoxidine by human CYP1A1 and rat microsomes:: identification of metabolites by high-performance liquid chromatography combined with electrospray tandem mass spectrometry and accurate mass measurements by time-of-flight mass spectrometry [J].
Deroussent, A ;
Ré, M ;
Hoellinger, H ;
Vanquelef, E ;
Duval, O ;
Sonnier, M ;
Cresteil, T .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (04) :474-482
[3]   Structural elucidation of metabolites of ritonavir and indinavir by liquid chromatography-mass spectrometry [J].
Gangl, E ;
Utkin, I ;
Gerber, N ;
Vouros, P .
JOURNAL OF CHROMATOGRAPHY A, 2002, 974 (1-2) :91-101
[4]   Interfacing the orbitrap mass analyzer to an electrospray ion source [J].
Hardman, M ;
Makarov, AA .
ANALYTICAL CHEMISTRY, 2003, 75 (07) :1699-1705
[5]   Elucidation of fragmentation mechanisms involving transfer of three hydrogen atoms using a quadrupole time-of-flight mass spectrometer [J].
Hop, CECA ;
Yu, X ;
Xu, X ;
Singh, R ;
Wong, BK .
JOURNAL OF MASS SPECTROMETRY, 2001, 36 (05) :575-579
[6]   Exact mass measurement of product ions for the structural elucidation of drug metabolites with a tandem quadrupole orthogonal-acceleration time-of-flight mass spectrometer [J].
Hopfgartner, G ;
Chernushevich, IV ;
Covey, T ;
Plomley, JB ;
Bonner, R .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (12) :1305-1314
[7]   The Orbitrap: a new mass spectrometer [J].
Hu, QZ ;
Noll, RJ ;
Li, HY ;
Makarov, A ;
Hardman, M ;
Cooks, RG .
JOURNAL OF MASS SPECTROMETRY, 2005, 40 (04) :430-443
[8]   Enhanced resolution triple-quadrupole mass spectrometry for fast quantitative bioanalysis using liquid chromatography/tandem mass spectrometry: investigations of parameters that affect ruggedness [J].
Jemal, M ;
Ouyang, Z .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (01) :24-38
[9]  
Kalgutkar Amit S, 2005, Expert Opin Drug Metab Toxicol, V1, P91, DOI 10.1517/17425255.1.1.91
[10]   Bioactivation of the nontricyclic antidepressant nefazodone to a reactive quinone-imine species in human liver microsomes and recombinant cytochrome P450 3A4 [J].
Kalgutkar, AS ;
Vaz, ADN ;
Lame, ME ;
Henne, KR ;
Soglia, J ;
Zhao, SX ;
Abramov, YA ;
Lombardo, F ;
Collin, C ;
Hendsch, ZS ;
Hop, CECA .
DRUG METABOLISM AND DISPOSITION, 2005, 33 (02) :243-253