Intravascular extraction of problematic or infected permanent pacemaker leads: 1994-1996

被引:199
作者
Byrd, CL
Wilkoff, BL
Love, CJ
Sellers, TD
Turk, KT
Reeves, R
Young, R
Crevey, B
Kutalek, SP
Freedman, R
Friedman, R
Trantham, J
Watts, M
Schutzman, J
Oren, J
Wilson, J
Gold, F
Fearnot, NE
Van Zandt, HJ
机构
[1] MED Inst, W Lafayette, IN 47906 USA
[2] Univ Miami, Sch Med, Miami, FL USA
[3] Cleveland Clin Fdn, Cleveland, OH 44195 USA
[4] Ohio State Univ, Columbus, OH 43210 USA
[5] Electrophysiol Associates PC, Colorado Springs, CO USA
[6] Nebraska Heart Inst, Lincoln, NE USA
[7] Cardiovasc Associates PC, Birmingham, AL USA
[8] SE Cardiovasc Inst, Rome, GA USA
[9] Methodist Hosp, Indianapolis, IN USA
[10] Med Coll Penn & Hahnemann Univ, Med Ctr, Philadelphia, PA USA
[11] Univ Utah, Hlth Sci Ctr, Salt Lake City, UT USA
[12] Texas Childrens Hosp, Houston, TX 77030 USA
[13] Cardiol Consultants, Pensacola, FL USA
[14] Univ Hosp, Augusta, GA USA
[15] Geisinger Med Ctr, Danville, PA 17822 USA
[16] Cardiol Associates, Cincinnati, OH USA
[17] Heartcare Midwest, Peoria, IL USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1999年 / 22卷 / 09期
关键词
lead removal; lead extraction; infection;
D O I
10.1111/j.1540-8159.1999.tb00628.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Of the 400,000-500,000 permanent pacemaker leads implanted worldwide each year, around 10% may eventually fail or become infected, becoming potential candidates for removal. Intravascular techniques for removing problematic or infected leads evolved over a 5-year period (1989-1993). This article analyzes results from January 1994 through April 1996, a period during which techniques were fairly stable. Extraction of 3,540 leads from 2,338 patients bl as attempted at 226 centers, indications were: infection (27%), nonfunctional or incompatible leads (25%), Accufix(R) or Encor(R) leads (46%), Or other ca uses (2%). Patients were 64 +/- 17 years of age (range 5-96); 59% were men, 41% women. Leads were implanted 47 +/- 41 months (maximum 26 years), in the atrium (53%), ventricle (46%), or SVC (1%). Extraction was attempted via the implant vein using locking stylets and dilator sheaths, and/or transfemorally using snares, retrieval baskets, and sheaths. Complete removal rr as achieved for 93% of leads, partial Ibr 5%, and 2% were not removed. Risk of incomplete or failed extraction increased with implant duration (P < 0.0002), less experienced physicians (P < 0.0001), ventricular leads (P < 0.005), noninfected patients IP < 0.0005), and younger patients (P < 0.0001). Major complications were reported for 1.4% of patients (< 1% at centers with > 300 cases), minor for 1.7%. Risk of-complications increased with number of leads removed (P < 0.005) and with less experienced physicians (P < 0.005); risk of major complications was higher for women (P < 0.01). Given physician experience, appropriate precautions, and appropriate patient selection, contemporary lead removal techniques allow success with low complication rates.
引用
收藏
页码:1348 / 1357
页数:10
相关论文
共 26 条
  • [1] Three-year experience with a stylet for lead extraction: A multicenter study
    Alt, E
    Neuzner, J
    Binner, L
    Gohl, K
    Res, JCJ
    Knabe, UH
    Zehender, M
    Reinhardt, J
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (01): : 18 - 25
  • [2] Survey of cardiac pacing and defibrillation in the United States in 1993
    Bernstein, AD
    Parsonnet, V
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (02) : 187 - 196
  • [3] INCARCERATION OF TRANSVENOUS PACEMAKER ELECTRODE . REMOVAL BY TRACTION
    BILGUTAY, AM
    JENSEN, NK
    SCHMIDT, WR
    GARAMELLA, JJ
    LYNCH, MF
    [J]. AMERICAN HEART JOURNAL, 1969, 77 (03) : 377 - +
  • [4] CHRONIC TRANSVENOUS PACEMAKER LEAD REMOVAL USING A UNIQUE, SEQUENTIAL TRANSVENOUS SYSTEM
    BRODELL, GK
    CASTLE, LW
    MALONEY, JD
    WILKOFF, BL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (12) : 964 - 966
  • [5] Byrd Charles L., 1992, Cardiology Clinics, V10, P735
  • [6] BYRD CL, 1991, J THORAC CARDIOV SUR, V101, P989
  • [7] BYRD CL, 1985, J THORAC CARDIOV SUR, V89, P142
  • [8] INTRAVASCULAR LEAD EXTRACTION USING LOCKING STYLETS AND SHEATHS
    BYRD, CL
    SCHWARTZ, SJ
    HEDIN, NB
    GOODE, LB
    FEARNOT, NE
    SMITH, HJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (12): : 1871 - 1875
  • [9] BYRD CL, 1996, PACE, V19, P577
  • [10] Byrd CL, 1997, PACE, V20, P1053