Low-threshold motor unit membrane properties vary with contraction intensity during sustained activation with surface EMG visual feedback

被引:38
作者
Farina, D [1 ]
Gazzoni, M [1 ]
Camelia, F [1 ]
机构
[1] Politecn Torino, Dipartimento Elettron, Lab Ingn Sistema Neuromuscolare, I-10129 Turin, Italy
关键词
firing rate; muscle fiber conduction velocity; linear electrode arrays; motor unit control; electromyogram;
D O I
10.1152/japplphysiol.01047.2003
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Single-motor unit (MU) activities were detected from the abductor pollicis and abductor digiti minimi muscles providing the subjects with visual feedback of multichannel surface electromyogram (EMG) signals. The subjects could modulate the force to observe on the surface recordings a single dominant MU and modulate its firing rate for contractions of 300 s with a noninvasive EMG feedback. The firing rate was maintained at similar to8 pulses per second [low-frequency (LF) contraction] and at similar to12 pulses per second [high-frequency (HF) contraction]. Single-MU conduction velocity (CV) decreased slightly but significantly over time, and it was possible to identify a significantly larger rate of decrease of CV during the HF with respect to the LF contractions. CV initial value significantly increased with the average firing rate, and CV values were significantly correlated to the instantaneous firing rate (R ranging from 0.21 to 0.39). Both additional MU recruitment and substitution were observed during the contractions. The study provides evidence that 1) it is possible to follow the same MU in a hand muscle at two different intensities ( HF and LF) for 300-s durations by using visual feedback of surface EMG, 2) low-threshold single-MU CV changes over time since the beginning of the contraction, and 3) it is possible to distinguish between CV changes of the same MU at slightly different firing rates. The technique provides a practical method for the noninvasive assessment of both control and membrane properties of single MUs.
引用
收藏
页码:1505 / 1515
页数:11
相关论文
共 48 条
[1]   MUSCLE-FIBER CONDUCTION-VELOCITY IN MOTOR UNITS OF THE HUMAN ANTERIOR TIBIAL MUSCLE - A NEW SIZE PRINCIPLE PARAMETER [J].
ANDREASSEN, S ;
ARENDTNIELSEN, L .
JOURNAL OF PHYSIOLOGY-LONDON, 1987, 391 :561-571
[2]   CHANGES IN MUSCLE-FIBER CONDUCTION-VELOCITY, MEAN POWER FREQUENCY, AND MEAN EMG VOLTAGE DURING PROLONGED SUBMAXIMAL CONTRACTIONS [J].
ARENDTNIELSEN, L ;
MILLS, KR ;
FORSTER, A .
MUSCLE & NERVE, 1989, 12 (06) :493-497
[3]   CONTROL AND TRAINING OF INDIVIDUAL MOTOR UNITS [J].
BASMAJIAN, JV .
SCIENCE, 1963, 141 (357) :440-&
[4]   CHANGES IN MUSCLE CONTRACTILE PROPERTIES AND NEURAL CONTROL DURING HUMAN MUSCULAR FATIGUE [J].
BIGLANDRITCHIE, B ;
WOODS, JJ .
MUSCLE & NERVE, 1984, 7 (09) :691-699
[5]   CONDUCTION-VELOCITY AND EMG POWER SPECTRUM CHANGES IN FATIGUE OF SUSTAINED MAXIMAL EFFORTS [J].
BIGLANDRITCHIE, B ;
DONOVAN, EF ;
ROUSSOS, CS .
JOURNAL OF APPLIED PHYSIOLOGY, 1981, 51 (05) :1300-1305
[6]   CONTROL SCHEME GOVERNING CONCURRENTLY ACTIVE HUMAN MOTOR UNITS DURING VOLUNTARY CONTRACTIONS [J].
DE LUCA, CJ ;
LEFEVER, RS ;
MCCUE, MP ;
XENAKIS, AP .
JOURNAL OF PHYSIOLOGY-LONDON, 1982, 329 (AUG) :129-142
[7]   Non-invasive approach of motor unit recording during muscle contractions in humans [J].
Disselhorst-Klug, C ;
Bahm, J ;
Ramaekers, V ;
Trachterna, A ;
Rau, G .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2000, 83 (2-3) :144-150
[8]   Improvement of spatial resolution in surface-EMG: A theoretical and experimental comparison of different spatial filters [J].
DisselhorstKlug, C ;
Silny, J ;
Rau, G .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (07) :567-574
[9]   MOTOR UNIT RECRUITMENT DURING PROLONGED ISOMETRIC CONTRACTIONS [J].
FALLENTIN, N ;
JORGENSEN, K ;
SIMONSEN, EB .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1993, 67 (04) :335-341
[10]   Noninvasive estimation of motor unit conduction velocity distribution using linear electrode arrays [J].
Farina, D ;
Fortunato, E ;
Merletti, R .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (03) :380-388