Plantar impact causing midfoot fractures result in higher forces in Chopart's joint than in the ankle joint

被引:26
作者
Richter, M
Wippermann, B
Thermann, H
Schroeder, G
Otte, D
Troeger, HD
Krettek, C
机构
[1] Hannover Med Sch, Trauma Dept, D-3000 Hannover, Germany
[2] Hannover Med Sch, Accid Res Unit, D-3000 Hannover, Germany
[3] Hannover Med Sch, Dept Forens Med, D-3000 Hannover, Germany
[4] ATOS Ctr Knee & Foot Surg, Heidelberg, Germany
关键词
midfoot fracture; plantar impact; joint pressure; ankle; Chopart;
D O I
10.1016/S0736-0266(01)00096-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose. Force effect (impact. extent or foot compartment deformation) and result (fracture pattern) for midfoot fractures in car occupants is known. An analysis of the processes in the foot was intended to improve car safety. Materials and methods. Eleven fresh. unfrozen. unpreserved intact human cadavers (age: 36.8 (16-61) years, gender: male, race: Caucasian) were studied 24-72 h after death. In 3 cadavers (5 feet) the experimental design was established: entire cadaver fixed on a special tray in supine position, pendulum with bar impactor hitting the foot plantar to Lisfranc's joint. A custom-made pressure sensor was inserted in the ankle (A), talonavicular (TN) and calcaneocuboid (CC) joints (resolution: 1 cm(2). sampling rate: 500/s). Results. Sixteen feet were measured; midfoot fractures were induced in I I feet. The maximum pressure amounted to 1.22-2.55 MPa (2.04 +/- 0.412) at 0.005-0.195 s (0.067 +/- 0.059) after impact. The maximum pressure Occurred in 8 (50%) cases in the ankle, in 7 (44% of the TN and 1 (6%) of the CC joints. A comparison of the first 200 pressure samples after impact of all sensor fields resulted in higher forces in Chopart's joint than in the ankle (t-test: p < 0.001). These force differences were higher in cases with midfoot fractures (mixed model analysis of variance: P = 0.003). *Conclusion. Due to considerable forces in Chopart's joint we recommend a modification of the actual crash test dummy lower extremity model with an additional load cell that detects forces in the longitudinal direction of the foot axis. (C) 2002 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:222 / 232
页数:11
相关论文
共 29 条
[1]
AMON K, 1990, UNFALLCHIRURG, V93, P431
[2]
BABST R, 1989, HELV CHIR ACTA, V56, P603
[3]
BRUTSCHER R, 1991, ORTHOPADE, V20, P67
[4]
LOWER-EXTREMITY INJURIES IN DRIVERS OF AIRBAG-EQUIPPED AUTOMOBILES - CLINICAL AND CRASH RECONSTRUCTION CORRELATIONS [J].
BURGESS, AR ;
DISCHINGER, PC ;
OQUINN, TD ;
SCHMIDHAUSER, CB .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1995, 38 (04) :509-516
[5]
Lower limb response and injury in frontal crashes [J].
Crandall, JR ;
Martin, PG ;
Sieveka, EM ;
Pilkey, WD ;
Dischinger, PC ;
Burgess, AR ;
O'Quinn, TD ;
Schmidhauser, CB .
ACCIDENT ANALYSIS AND PREVENTION, 1998, 30 (05) :667-677
[6]
Frequency content of normal and diabetic plantar pressure profiles: Implications for the selection of transducer sizes [J].
Davis, BL ;
Cothren, RM ;
Quesada, P ;
Hanson, SB ;
Perry, JE .
JOURNAL OF BIOMECHANICS, 1996, 29 (07) :979-983
[7]
LOWER-EXTREMITY FRACTURES IN MOTOR-VEHICLE COLLISIONS - THE ROLE OF DRIVER GENDER AND HEIGHT [J].
DISCHINGER, PC ;
KERNS, TJ ;
KUFERA, JA .
ACCIDENT ANALYSIS AND PREVENTION, 1995, 27 (04) :601-606
[8]
Lower limb injuries to passenger car occupants [J].
Fildes, B ;
Lenard, J ;
Lane, J ;
Vulcan, P ;
Seyer, K .
ACCIDENT ANALYSIS AND PREVENTION, 1997, 29 (06) :785-791
[9]
Graziano T A, 1984, J Foot Surg, V23, P445
[10]
RELIABILITY OF PRESSURE MEASUREMENTS - THE EMED F SYSTEM [J].
HUGHES, J ;
PRATT, L ;
LINGE, K ;
CLARK, P ;
KLENERMAN, L .
CLINICAL BIOMECHANICS, 1991, 6 (01) :14-18