Element- and isotope-specific detection for high-performance liquid chromatography using chemical reaction interface mass spectrometry

被引:22
作者
McLean, M
Vestal, ML
Teffera, Y
Abramson, FP
机构
[1] GEORGE WASHINGTON UNIV,MED CTR,DEPT PHARMACOL RE6640,WASHINGTON,DC 20037
[2] VESTEC MASS SPECTROMETRY PROD,PERSEPT BIOSYS,HOUSTON,TX 77054
关键词
detection; LC; mass spectrometry; chemical reaction interface mass spectrometry; element-specific detection; isotope-specific detection;
D O I
10.1016/0021-9673(95)01279-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have developed a combination of high-performance liquid chromatography (HPLC) and the chemical reaction interface mass spectrometry (CRIMS) method by using a Vestee Universal Interface (UI). This interface provides the extremely high degree of solvent removal that the CRIMS process requires. In doing so, we have produced an HPLC detector with the ability to carry out element- and isotope-selective analyses with detection that is inherently: linear, structure-independent, sensitive, selective, comprehensive and flexible. The characteristics of the instrumentation and its performance are described.
引用
收藏
页码:189 / 199
页数:11
相关论文
共 23 条
[1]  
ABRAMSON FP, 1992, SYNTHESIS AND APPLICATIONS OF ISOTOPICALLY LABELLED COMPOUNDS 1991, P133
[2]   ISOTOPE-DILUTION STUDIES - DETERMINATION OF C-13, N-15 AND DEUTERIUM-ENRICHED COMPOUNDS USING CAPILLARY GAS-CHROMATOGRAPHY CHEMICAL-REACTION INTERFACE MASS-SPECTROMETRY [J].
CHACE, DH ;
ABRAMSON, FP .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1990, 19 (03) :117-122
[3]   SELECTIVE DETECTION OF C-13, N-15, AND DEUTERIUM LABELED METABOLITES BY CAPILLARY GAS-CHROMATOGRAPHY CHEMICAL-REACTION INTERFACE MASS-SPECTROMETRY [J].
CHACE, DH ;
ABRAMSON, FP .
ANALYTICAL CHEMISTRY, 1989, 61 (24) :2724-2730
[4]  
CHACE DH, 1989, SYNTHESIS APPLICATIO, P253
[6]   STUDIES ON DRUG-METABOLISM USING LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY - COMPARISON OF 3 LIQUID-CHROMATOGRAPHIC MASS-SPECTROMETRIC INTERFACES [J].
IWABUCHI, H ;
KITAZAWA, E ;
KOBAYASHI, N ;
WATANABE, H ;
KANAI, M ;
NAKAMURA, K .
BIOLOGICAL MASS SPECTROMETRY, 1994, 23 (09) :540-546
[7]  
LI G, 1994, 42 ANN ASMS C MASS S, P617
[8]   CAPILLARY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY WITH A MICROWAVE-DISCHARGE INTERFACE FOR DETERMINATION OF RADIOACTIVE-CARBON-CONTAINING COMPOUNDS [J].
MARKEY, SP ;
ABRAMSON, FP .
ANALYTICAL CHEMISTRY, 1982, 54 (13) :2375-2376
[9]   A MOVING BELT DEVICE TO COUPLE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND CHEMICAL-REACTION INTERFACE MASS-SPECTROMETRY [J].
MOINI, M ;
ABRAMSON, FP .
BIOLOGICAL MASS SPECTROMETRY, 1991, 20 (05) :308-312
[10]   SELECTIVE DETECTION OF SULFUR-CONTAINING-COMPOUNDS BY GAS-CHROMATOGRAPHY CHEMICAL-REACTION INTERFACE MASS-SPECTROMETRY [J].
MOINI, M ;
CHACE, D ;
ABRAMSON, FP .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (03) :250-255