High-throughput analysis of tetracycline and penicillin antibiotics in animal tissues using electrospray tandem mass spectrometry with selected reaction monitoring transition

被引:75
作者
Goto, T
Ito, Y
Yamada, S
Matsumoto, H
Oka, H
机构
[1] Kinjogakuin Univ, Fac Pharm, Moriyama Ku, Nagoya, Aichi 4638521, Japan
[2] Aichi Prefectural Inst Publ Hlth, Kita Ku, Nagoya, Aichi 4628576, Japan
关键词
tetracycline; Penicillins; animal tissues; ESI LC-MS/MS;
D O I
10.1016/j.chroma.2005.09.056
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, rapid, and simultaneous analysis method for oxytertracycline, tetracycline, chlortetracycline, penicillin G, ampicillin, and nafcillin in meat has been developed by using electrospray ionization tandem mass spectrometry. The sample preparation was performed by homogenizing with water followed by a centrifugal ultrafiltration, after addition of internal standards (demeclocycline, penicillin G-d5, ampicillin-d5 and nafcillin-d6). The MS/MS analysis involves the combined use of sample enrichment on the short column and a multiple reaction monitoring technique. The overall recoveries from animal (bovine and swine) muscle, kidney, and liver fortified at the levels of 0.05 and 0.1 ppm ranged from 70 to 115% with the coefficients of variation ranging from 0.7 to 14.8% (n = 5). Analysis time, including sample preparation and determination, is only 3 h per eight sample and detection limits for all antibiotics are 0.002 ppm. The method is considered to be satisfactory for the rapid screening of the tetracycline and penicillin antibiotic residues in meat. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:193 / 199
页数:7
相关论文
共 23 条
[1]   An HPLC method for the determination of penicillin G residues in veal calf liver tissues [J].
Boison, JO ;
Souster, K ;
Drury, C ;
Musser, JB ;
Anderson, KL .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2001, 24 (06) :881-892
[2]  
Boison JO, 1995, CHEM ANAL ANTIBIOTIC, P235
[3]   Quantitative multi-residue analysis of tetracyclines and their 4-epimers in pig tissues by high-performance liquid chromatography combined with positive-ion electrospray ionization mass spectrometry [J].
Cherlet, M ;
Schelkens, M ;
Croubels, S ;
De Backer, P .
ANALYTICA CHIMICA ACTA, 2003, 492 (1-2) :199-213
[4]   Improved method for the on-line metal chelate affinity chromatography high-performance liquid chromatographic determination of tetracycline antibiotics in animal products [J].
Cooper, AD ;
Stubbings, GWF ;
Kelly, M ;
Tarbin, JA ;
Farrington, WHH ;
Shearer, G .
JOURNAL OF CHROMATOGRAPHY A, 1998, 812 (1-2) :321-326
[5]   Use of metal chelate affinity chromatography and membrane-based ion-exchange as clean-up procedure for trace residue analysis of tetracyclines in animal tissues and egg [J].
Croubels, SM ;
Vanoosthuyze, KEI ;
VanPeteghem, CH .
JOURNAL OF CHROMATOGRAPHY B, 1997, 690 (1-2) :173-179
[6]  
ENKE CG, 1998, ANAL CHEM, V1885, P69
[7]   The high throughput analysis of N-methyl carbamate pesticides in wine and juice by electrospray ionization liquid chromatography tandem mass spectrometry with direct sample injection into a short column [J].
Goto, T ;
Ito, Y ;
Oka, H ;
Saito, I ;
Matsumoto, H ;
Sugiyama, H ;
Ohkubo, C ;
Nakazawa, H ;
Nagase, H .
ANALYTICA CHIMICA ACTA, 2005, 531 (01) :79-86
[8]   Simultaneous determination of five penicillins in muscle, liver and kidney from slaughtered animals using liquid chromatography coupled with electrospray ionization tandem mass spectrometry [J].
Hatano, K .
JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 2003, 44 (01) :1-6
[9]   Application of ion-exchange cartridge clean-up in food analysis - II. Determination of benzylpenicillin, phenoxymethylpenicillin, oxacillin, cloxacillin, nafcillin and dicloxacillin in meat using liquid chromatography with ultraviolet detection [J].
Ito, Y ;
Ikai, Y ;
Oka, H ;
Kagami, T ;
Takeba, K .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) :247-253
[10]   Application of ion-exchange cartridge clean-up in food analysis I. Simultaneous determination of thiabendazole and imazalil in citrus fruit and banana using high-performance liquid chromatography with ultraviolet detection [J].
Ito, Y ;
Ikai, Y ;
Oka, H ;
Hayakawa, J ;
Kagami, T .
JOURNAL OF CHROMATOGRAPHY A, 1998, 810 (1-2) :81-87