Determination of reliability criteria for liver stiffness evaluation by transient elastography

被引:532
作者
Boursier, Jerome [1 ,2 ]
Zarski, Jean-Pierre [3 ,4 ]
de Ledinghen, Victor [5 ,6 ]
Rousselet, Marie-Christine [2 ,7 ]
Sturm, Nathalie [8 ]
Lebail, Brigitte [9 ]
Fouchard-Hubert, Isabelle [1 ,2 ]
Gallois, Yves [2 ,10 ]
Oberti, Frederic [1 ,2 ]
Bertrais, Sandrine [2 ]
Cales, Paul [1 ,2 ]
机构
[1] Univ Hosp, Liver Gastroenterol Dept, Angers, France
[2] LUNAM Univ, SFR 4038, HIFIH Lab, UPRES 3859, Angers, France
[3] Univ Hosp, Liver Gastroenterol Dept, Grenoble, France
[4] UJF, INSERM, U823, IAPC,IAB, Grenoble, France
[5] Haut Leveque Univ Hosp, Liver Gastroenterol Dept, Pessac, France
[6] Segalen Bordeaux Univ, INSERM, U1053, Bordeaux, France
[7] Univ Hosp, Dept Pathol, Angers, France
[8] Univ Hosp, Dept Pathol, Grenoble, France
[9] Univ Hosp, Dept Pathol, Bordeaux, France
[10] Univ Hosp, Dept Biochem, Angers, France
关键词
CHRONIC HEPATITIS-C; NONINVASIVE DIAGNOSIS; FIBROSIS; REPRODUCIBILITY; ACCURACY; PERFORMANCE; CIRRHOSIS; CURVE; AREAS; TESTS;
D O I
10.1002/hep.25993
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Liver stiffness evaluation (LSE) is usually considered as reliable when it fulfills all the following criteria: 10 valid measurements, 60% success rate, and interquartile range / median ratio (IQR/M) 0.30. However, such reliable LSE have never been shown to be more accurate than unreliable LSE. Thus, we aimed to evaluate the relevance of the usual definition for LSE reliability, and to improve reliability by using diagnostic accuracy as a primary outcome in a large population. 1,165 patients with chronic liver disease from 19 French centers were included. All patients had liver biopsy and LSE. 75.7% of LSE were reliable according to the usual definition. However, these reliable LSE were not significantly more accurate than unreliable LSE with, respectively: 85.8% versus 81.5% well-classified patients for the diagnosis of cirrhosis (P = 0.082). In multivariate analyses with different diagnostic targets, LSE median and IQR/M were independent predictors of fibrosis staging, with no significant influence of 10 valid measurements or LSE success rate. These two reliability criteria determined three LSE groups: very reliable (IQR/M 0.10), reliable (0.10< IQR/M 0.30, or IQR/M >0.30 with LSE median <7.1 kPa), and poorly reliable (IQR/M >0.30 with LSE median 7.1 kPa). The rates of well-classified patients for the diagnosis of cirrhosis were, respectively: 90.4%, 85.8%, and 69.5% (P < 103). According to these new reliability criteria, 9.1% of LSE were poorly reliable (versus 24.3% unreliable LSE with the usual definition, P < 103), 74.3% were reliable, and 16.6% were very reliable. Conclusion: The usual definition for LSE reliability is not relevant. LSE reliability depends on IQR/M according to liver stiffness median level, defining thus three reliability categories: very reliable, reliable, and poorly reliable LSE. (HEPATOLOGY 2013)
引用
收藏
页码:1182 / 1191
页数:10
相关论文
共 34 条
[1]   Comparison of accuracy of fibrosis degree classifications by liver biopsy and non-invasive tests in chronic hepatitis C [J].
Boursier, Jerome ;
Bertrais, Sandrine ;
Oberti, Frederic ;
Gallois, Yves ;
Fouchard-Hubert, Isabelle ;
Rousselet, Marie-Christine ;
Zarski, Jean-Pierre ;
Cales, Paul .
BMC GASTROENTEROLOGY, 2011, 11
[2]   Comparison of eight diagnostic algorithms for liver fibrosis in hepatitis C: new algorithms are more precise and entirely noninvasive [J].
Boursier, Jerome ;
de Ledinghen, Victor ;
Zarski, Jean-Pierre ;
Fouchard-Hubert, Isabelle ;
Gallois, Yves ;
Oberti, Frederic ;
Cales, Paul .
HEPATOLOGY, 2012, 55 (01) :58-67
[3]   A New Combination of Blood Test and Fibroscan for Accurate Non-Invasive Diagnosis of Liver Fibrosis Stages in Chronic Hepatitis C [J].
Boursier, Jerome ;
de Ledinghen, Victor ;
Zarski, Jean-Pierre ;
Rousselet, Marie-Christine ;
Sturm, Nathalie ;
Foucher, Juliette ;
Leroy, Vincent ;
Fouchard-Hubert, Isabelle ;
Bertrais, Sandrine ;
Gallois, Yves ;
Oberti, Frederic ;
Dib, Nina ;
Cales, Paul .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2011, 106 (07) :1255-1263
[4]   Reproducibility of Liver Stiffness Measurement by Ultrasonographic Elastometry [J].
Boursier, Jerome ;
Konate, Anselme ;
Gorea, Gabriella ;
Reaud, Stephanie ;
Quemener, Emmanuel ;
Oberti, Frederic ;
Hubert-Fouchard, Isabelle ;
Dib, Nina ;
Cales, Paul .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2008, 6 (11) :1263-1269
[5]   Learning curve and interobserver reproducibility evaluation of liver stiffness measurement by transient elastography [J].
Boursler, Jerome ;
Konate, Anselme ;
Guilluy, Marine ;
Gorea, Gabriella ;
Sawadogo, Apollinalre ;
Quemener, Emmanuel ;
Oberti, Frederic ;
Reaud, Stephane ;
Hubert-Fouchard, Isabelle ;
Dib, Nina ;
Cales, Paul .
EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2008, 20 (07) :693-701
[6]   Prospective comparison of transient elastography, fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C [J].
Castéra, L ;
Vergniol, J ;
Foucher, J ;
Le Bail, B ;
Chanteloup, E ;
Haaser, M ;
Darriet, M ;
Couzigou, P ;
De Lédinghen, V .
GASTROENTEROLOGY, 2005, 128 (02) :343-350
[7]   Non-invasive evaluation of liver fibrosis using transient elastography [J].
Castera, Laurent ;
Forns, Xavier ;
Alberti, Alfredo .
JOURNAL OF HEPATOLOGY, 2008, 48 (05) :835-847
[8]   Pitfalls of Liver Stiffness Measurement: A 5-Year Prospective Study of 13,369 Examinations [J].
Castera, Laurent ;
Foucher, Juliette ;
Bernard, Pierre-Henri ;
Carvalho, Francoise ;
Allaix, Daniele ;
Merrouche, Wassil ;
Couzigou, Patrice ;
de Ledinghen, Victor .
HEPATOLOGY, 2010, 51 (03) :828-835
[9]   Transient elastography: a new surrogate marker of liver fibrosis influenced by major changes of transaminases [J].
Coco, B. ;
Oliveri, F. ;
Maina, A. M. ;
Ciccorossi, P. ;
Sacco, R. ;
Colombatto, P. ;
Bonino, F. ;
Brunetto, M. R. .
JOURNAL OF VIRAL HEPATITIS, 2007, 14 (05) :360-369
[10]   Diagnostic accuracy of FibroScan and comparison to liver fibrosis biomarkers in chronic viral hepatitis: A multicenter prospective study (the FIBROSTIC study) [J].
Degos, Francoise ;
Perez, Paul ;
Roche, Bruno ;
Mahmoudi, Amel ;
Asselineau, Julien ;
Voitot, Helene ;
Bedossa, Pierre .
JOURNAL OF HEPATOLOGY, 2010, 53 (06) :1013-1021