Charged cyclodextrin-mediated sample stacking in micellar capillary electrophoresis - A simple method for enhancing the detection sensitivity of hydrophobic compounds

被引:30
作者
Munro, NJ
Palmer, J
Stalcup, AM
Landers, JP [1 ]
机构
[1] Univ Pittsburgh, Dept Chem, Pittsburgh, PA 15260 USA
[2] Univ Cincinnati, Dept Chem, Cincinnati, OH 45221 USA
来源
JOURNAL OF CHROMATOGRAPHY B | 1999年 / 731卷 / 02期
关键词
stacking; micellar electrokinetic chromatography; estrogens; sulfated beta-cyclodextrin; cyclodextrins;
D O I
10.1016/S0378-4347(99)00258-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The development of on-line sample stacking techniques for enhancing limits of detection of neutral analytes in micellar capillary electrophoresis (MCE) has recently gained much attention. Utilizing high-conductivity sample matrices to invoke sample stacking is promising, but requires the limited use of sample solubilizing agents such as alcohols in the sample matrix. In this study, we show how simple replacement of the sample solvent (methanol) with a solution of sulfated beta-cyclodextrin (s beta-CD) allows a significant increase in the sensitivity of detection of model hydrophobic analytes. This increase in sensitivity is accompanied by significant peak sharpening. Sulfated CDs in the sample matrix allow for effective solubilization of hydrophobic analytes without the use of organic solvents such as methanol. The testing of various sample matrix s beta-CD concentrations for their effect on peak sharpening identified 3 to 5% as optimal for the estrogen standards. The use of a s beta-CD sample matrix allowed for hydrostatic injections (3.5 kPa) of 297 s, compared with 4 s when the analytes were dissolved in methanol. A mechanism explaining the sp-Cn-induced effect involves an analyte transfer mechanism where the s beta-CDs, despite providing anodic mobility to analytes in the sample zone, are able to transfer analytes to trailing separation buffer micelles for "recycling" back into the sample zone without compromising the stacking process. The overall improvement in sensitivity allows detection of estrogens in the parts-per-billion range and stands to improve the utility of MCE as a bioanalytical technique. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:369 / 381
页数:13
相关论文
共 15 条
[1]   FIELD AMPLIFIED SAMPLE INJECTION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :141-152
[2]   SEPARATION OF URINARY ESTROGENS BY MICELLAR ELECTROKINETIC CHROMATOGRAPHY [J].
JI, AJ ;
NUNEZ, MF ;
MACHACEK, D ;
FERGUSON, JE ;
IOSSI, MF ;
KAO, PC ;
LANDERS, JP .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1995, 669 (01) :15-26
[3]   FIELD-AMPLIFIED SAMPLE STACKING IN MICELLAR ELECTROKINETIC CHROMATOGRAPHY FOR ON-COLUMN SAMPLE CONCENTRATION OF NEUTRAL MOLECULES [J].
LIU, ZY ;
SAM, P ;
SIRIMANNE, SR ;
MCCLURE, PC ;
GRAINGER, J ;
PATTERSON, DG .
JOURNAL OF CHROMATOGRAPHY A, 1994, 673 (01) :125-132
[4]  
MIYAJIMA K, 1986, CHEM PHARM BULL, V34, P1395
[5]  
MUNRO NJ, 1998, P S HIGH PERF CAP EL
[6]   ZONE SHARPENING OF NEUTRAL SOLUTES IN MICELLAR ELECTROKINETIC CHROMATOGRAPHY WITH ELECTROKINETIC INJECTION [J].
NIELSEN, KR ;
FOLEY, JP .
JOURNAL OF CHROMATOGRAPHY A, 1994, 686 (02) :283-291
[7]   ALPHA,OMEGA-BIS-QUATERNARY AMMONIUM ALKANES AS EFFECTIVE BUFFER ADDITIVES FOR ENHANCED CAPILLARY ELECTROPHORETIC SEPARATION OF GLYCOPROTEINS [J].
ODA, RP ;
MADDEN, BJ ;
SPELSBERG, TC ;
LANDERS, JP .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (01) :85-92
[8]   A universal concept for stacking neutral analytes in micellar capillary electrophoresis [J].
Palmer, J ;
Munro, NJ ;
Landers, JP .
ANALYTICAL CHEMISTRY, 1999, 71 (09) :1679-1687
[9]   On-line concentration of neutral analytes for micellar electrokinetic chromatography. 3. Stacking with reverse migrating micelles [J].
Quirino, JP ;
Terabe, S .
ANALYTICAL CHEMISTRY, 1998, 70 (01) :149-157
[10]   On line concentration of neutral analytes for micellar electrokinetic chromatography. 5. Field enhanced sample injection with reverse migrating micelles [J].
Quirino, JP ;
Terabe, S .
ANALYTICAL CHEMISTRY, 1998, 70 (09) :1893-1901