Raman spectroscopy for process/quality control

被引:58
作者
Adar, F
Geiger, R
Noonan, J
机构
[1] Instruments, S.A., JY/Spex/Dilor Raman Spectrosc. E.S., Edison, NJ 08820
关键词
D O I
10.1080/05704929508001133
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Analytical instrumentation, especially Near Infrared (NIR), and Gas Chromatography (GC) has been applied for a considerable number of years to the monitor and control of chemical manufacturing processes. By measuring the chemical species at the time and place of manufacture it becomes possible to modify the quantities of feedstock and the physical conditions, either manually or automatically, in order to improve the efficiency of the process and/or the quality of the product. While the information content of Raman spectra was always attractive for this type of application, implementation of Raman instrumentation was impractical until the last several years. The evolution of Raman instrumentation in the last 5 years, as well as the implementation of the mathematical data treatments that provide the needed quantitative information will be reviewed. Applications that are in the public domain will be described. This includes monitoring quality of hard carbon coatings on computer hard discs, chemical composition (mixtures, solvent separations, reactions such as polymerization, hydrogenation and curing etc.), gas composition, fermentation, polymorphy in pharmaceuticals, and polymer morphology. Rather than attempting to be exhaustive, the topics and literature covered will be selective - we will attempt to describe the state-of-the-art of a rapidly developing field, and give a sense of its potential.
引用
收藏
页码:45 / 101
页数:57
相关论文
共 114 条
  • [1] RAMAN MICROPROBE SPECTRA OF SPIN-ORIENTED AND DRAWN FILAMENTS OF POLY(ETHYLENE-TEREPHTHALATE)
    ADAR, F
    NOETHER, H
    [J]. POLYMER, 1985, 26 (13) : 1935 - 1943
  • [2] ADAR F, 1987, MICROBEAM ANAL 1987, P141
  • [3] A STUDY OF THE AUTOXIDATION OF SOME UNSATURATED FATTY-ACID METHYL-ESTERS USING FOURIER-TRANSFORM RAMAN-SPECTROSCOPY
    AGBENYEGA, JK
    CLAYBOURN, M
    ELLIS, G
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1991, 47 (9-10): : 1375 - 1388
  • [4] AGER JW, 1992, IEEE T MAGN
  • [5] NEAR-INFRARED RAMAN-SPECTROSCOPY OF LIQUIDS AND SOLIDS WITH A FIBEROPTIC SAMPLER, DIODE-LASER, AND CCD DETECTOR
    ALLRED, CD
    MCCREERY, RL
    [J]. APPLIED SPECTROSCOPY, 1990, 44 (07) : 1229 - 1231
  • [6] ANGEL SM, 1995, SPIE, V2504
  • [7] ANGEL SM, 1991, SPIE, V1587, P219
  • [8] ANGEL SM, 1990, APPL OPTICS, P1350
  • [9] [Anonymous], 1989, MULTIVARIATE CALIBRA
  • [10] Novel in situ probe for monitoring polymer curing
    Aust, JF
    Booksh, KS
    Myrick, ML
    [J]. APPLIED SPECTROSCOPY, 1996, 50 (03) : 382 - 387