Biocompatibility evaluation of dura mater substitutes in an animal model

被引:62
作者
Barbolt, TA
Odin, M
Léger, M
Kangas, L
Holste, J
Liu, SH
机构
[1] Ethicon Inc, Div Res & Dev, Somerville, NJ USA
[2] Merck Chibret, Riom, France
[3] ClinTrials BioRes Ltd, Senneville, PQ, Canada
[4] Ethicon GmbH, Norderstedt, Germany
关键词
dura mater substitute; neurologic; absorbable; tissue reaction; animal model;
D O I
10.1179/016164101101199405
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Dura-Guard (R) Dural Repair Patch, PRECLUDE (R) Dura Substitute, and Codman (R) ETHISORB (TM) Dura Patch were evaluated in a six-month dural tissue reaction study in rabbits. Bilateral craniotomy was followed by subdural implantation for each dura mater substitute. The surgical procedure for the sham control group was the same except that no material was implanted. Implantation of all of these dura mater substitutes for 28, 91, or 182 days post-implantation did not result in any deaths or clinical neurobehavioral abnormalities, changes in cerebrospinal fluid, or significant macroscopic changes at necropsy. However, histomorphologic evaluation of the implantation sites revealed some differences in the tissue response to these materials. For Dura-Guard Dural Repair Patch, a nonabsorbable material derived from bovine pericardium, the implantation site was characterized by fibrosis of the overlying area with islands of osseous metaplasia and adhesions to the brain surface. Over time, infiltrative fibrosis of the implant resulted in separation of the collagenous layers of the implant and compression of the underlying brain. Fibrosis of the overlying area that incorporated this material formed a 'replacement' dura mater. Adhesions to the brain surface observed initially were still present at six months post-implantation. Implantation of PRECLUDE Dura Substitute, a nonabsorbable material comprised of expanded polytetrafluoroethylene, resulted in virtually no early reaction, and few adhesions to the brain surface at any time period. Although this material was eventually incorporated by fibrosis, islands of osseous metaplasia were also observed in this 'replacement' dura mater. The tissue reaction to Codman ETHISORB Dura Patch, an absorbable material comprised of polyglactin 910 and polydioxanone, was generally characterized by low-grade granulomatous inflammation and initial adhesions to the brain surface. The three-dimensional structure of this implant acted as a scaffold to guide the development and integration of a 'replacement' dura mater. The absorption of the material was associated with complete resolution of the inflammatory reaction, a lack of cerebral adhesions, and restoration of the normal architecture of this region. In conclusion, subdural implantation of Dura-Guard Dural Repair Patch, PRECLUDE Dura Substitute, or Codman ETHISORB Dura Patch in rabbits for up to six months resulted in the eventual restoration of the dura mater without significant adverse effects. However, osseous metaplasia associated with nonabsorbable Dura-Guard Dural Repair Patch and PRECLUDE Dura Substitute, and the infiltration of Dura-Guard Dural Repair Patch by fibrosis suggests that long-term follow-up may be needed after the use of these materials in patients. An advantage of Codman ETHISORB Dura Patch was that it was completely absorbed after guiding the restoration of the dura mater without any morphological sequelae.
引用
收藏
页码:813 / 820
页数:8
相关论文
共 11 条
[1]   A review of dural substitutes used in neurosurgery [J].
Berjano, R ;
Vinas, FC ;
Dujovny, M .
CRITICAL REVIEWS IN NEUROSURGERY, 1999, 9 (04) :217-222
[2]   USE OF COLLAGEN FILM AS A DURAL SUBSTITUTE - PRELIMINARY ANIMAL STUDIES [J].
COLLINS, RLL ;
CHRISTIANSEN, D ;
ZAZANIS, GA ;
SILVER, FH .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (02) :267-276
[3]   ABSORBABLE SCLERAL IMPLANTS IN SURGERY OF RETINAL-DETACHMENT - 1ST RESULTS OF ANIMAL-EXPERIMENTS [J].
GUTHOFF, R ;
WAGNER, T ;
HOLSTE, J ;
WINTER, R .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1993, 202 (01) :43-48
[4]   Transmissible spongiform encephalopathies [J].
Haywood, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 337 (25) :1821-1828
[5]   PEDIATRIC CREUTZFELDT-JAKOB-DISEASE - PROBABLE TRANSMISSION BY A DURAL GRAFT [J].
MARTINEZLAGE, JF ;
SOLA, J ;
POZA, M ;
ESTEBAN, JA .
CHILDS NERVOUS SYSTEM, 1993, 9 (04) :239-242
[6]   VICRYL (POLYGLACTIN-910) MESH AS A DURAL SUBSTITUTE [J].
MAURER, PK ;
MCDONALD, JV .
JOURNAL OF NEUROSURGERY, 1985, 63 (03) :448-452
[7]  
SALLER U, 1991, ETHICON OP FORUM, V148, P2
[8]   A new technique of dural closure - Experience with a vicryl mesh [J].
Verheggen, R ;
SchulteBaumann, WJ ;
Hahm, G ;
Lang, J ;
Freudenthaler, S ;
Schaake, T ;
Markakis, E .
ACTA NEUROCHIRURGICA, 1997, 139 (11) :1074-1079
[9]   Evaluation of expanded polytetrafluoroethylene (ePTFE) versus polydioxanone (PDS) for the repair of dura mater defects [J].
Viñas, FC ;
Ferris, D ;
Kupsky, WJ ;
Dujovny, M .
NEUROLOGICAL RESEARCH, 1999, 21 (03) :262-268
[10]   Examination of the safety and efficacy of an absorbable dura mater substitute (Dura Patch®) in normal applications in neurosurgery [J].
von Wild, KRH .
SURGICAL NEUROLOGY, 1999, 52 (04) :418-424