Simultaneous heart rate-motion sensor technique to estimate energy expenditure

被引:84
作者
Strath, SJ [1 ]
Bassett, DR [1 ]
Swartz, AM [1 ]
Thompson, DL [1 ]
机构
[1] Univ Tennessee, Dept Exercise Sci & Sport Management, Knoxville, TN 37996 USA
关键词
physical activity; oxygen uptake; exercise; pedometer; accelerometer;
D O I
10.1097/00005768-200112000-00022
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: Heart rate (HR) and motion sensors represent promising tools for physical activity (PA) assessment, Lt.,, each prod ides an estimate of energy expenditure (EE). Although each has inherent limitations. the simultaneous use of HR and motion sensors may increase the accuracy of EE estimates. The primary purpose of this study was to establish the accuracy of predicting EE from the simultaneous HR-motion sensor technique. In addition, the accuracy of EE estimated by the simultaneous HR-motion sen. or technique was compared to that of HR and motion sensors used independently. Methods: Thirty participants (16 men: age. 33.1 +/- 12.2 yr: BMI, 20.1 +/- 0.7 kg.m (2): and 14 women: age, 31.9 +/- 13.1 yr: BMI. 27.2 +/- 1.1 kg.m(-2) (mean +/- SD)) performed arni and leg work in the laboratory for the purpose of developing individualized HR-VO2 regression equations. Participants then performed physical tasks in a field setting for 15 min each. CSA accelerometers placed on the arm and leg were to discriminate between upper and lower body movement, and HR was then used to predict EE (METs) from the corresponding arm or leg, laboratory regression equation. A hip-mounted CSA accelerometer and Yamax pedometer were also used to predict EE. Predicted values (METs) were compared to measured values (METs). obtained via a portable metabolic measurement system (Cosmed K4b(2)). Results: The Yamax pedometer and the CSA accelerometer on the hip significantly underestimated the energy cost of selected physical activities. whereas HR alone significantly overestimated the energy cost of selected physical activities. The simultaneous HR-motion sensor technique showed the strongest relationship with (V)over dotO(2) (R-2 = 0.81) and did not significantly over- or underpredict the energy cost (P = 0.341). Conclusion: The simultaneous HR-motion sensor technique is a good predictor of EE during selected lifestyle activities. and allows researchers to more accurately quantify free-living PA.
引用
收藏
页码:2118 / 2123
页数:6
相关论文
共 26 条
[1]   Compendium of Physical Activities: an update of activity codes and MET intensities [J].
Ainsworth, BE ;
Haskell, WL ;
Whitt, MC ;
Irwin, ML ;
Swartz, AM ;
Strath, SJ ;
O'Brien, WL ;
Bassett, DR ;
Schmitz, KH ;
Emplaincourt, PO ;
Jacobs, DR ;
Leon, AS .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S498-S516
[2]   Accuracy of recall of occupational physical activity by questionnaire [J].
Ainsworth, BE ;
Richardson, MT ;
Jacobs, DR ;
Leon, AS ;
Sternfeld, B .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 1999, 52 (03) :219-227
[3]   Validity of four motion sensors in measuring moderate intensity physical activity [J].
Bassett, DR ;
Ainsworth, BE ;
Swartz, AM ;
Strath, SJ ;
O'Brien, WL ;
King, GA .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S471-S480
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Free-living energy expenditure of adult men assessed by continuous heart-rate monitoring and doubly-labelled water [J].
Davidson, L ;
McNeill, G ;
Haggarty, P ;
Smith, JS ;
Franklin, MF .
BRITISH JOURNAL OF NUTRITION, 1997, 78 (05) :695-708
[6]   Calibration of the Computer Science and Applications, Inc. accelerometer [J].
Freedson, PS ;
Melanson, E ;
Sirard, J .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1998, 30 (05) :777-781
[7]   SIMULTANEOUS MEASUREMENT OF HEART-RATE AND BODY MOTION TO QUANTITATE PHYSICAL-ACTIVITY [J].
HASKELL, WL ;
YEE, MC ;
EVANS, A ;
IRBY, PJ .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1993, 25 (01) :109-115
[8]   PHYSICAL-ACTIVITY AND REDUCED OCCURRENCE OF NON-INSULIN-DEPENDENT DIABETES-MELLITUS [J].
HELMRICH, SP ;
RAGLAND, DR ;
LEUNG, RW ;
PAFFENBARGER, RS .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 325 (03) :147-152
[9]   Validity of accelerometry for the assessment of moderate intensity physical activity in the field [J].
Hendelman, D ;
Miller, K ;
Bagget, C ;
Debold, E ;
Freedson, P .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S442-S449
[10]  
Hiilloskorpi H, 1999, INT J SPORTS MED, V20, P438