Measurement of bone mineral density is possible with standard radiographs -: A study involving total knee replacement

被引:23
作者
Hernandez-Vaquero, D [1 ]
Garcia-Sandoval, MA
Fernandez-Carreira, JM
Suarez-Vázquez, A
Perez-Hernández, D
机构
[1] Univ Oviedo, Sch Med, Dept Orthopaed Surg, Hosp Agustin, Oviedo, Spain
[2] Univ Oviedo, Sch Med, Clin Res Unit, Hosp Agustin, Oviedo, Spain
关键词
D O I
10.1080/17453670510045381
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Measured bone density correlates well with the mechanical properties of the bone. Our objective was to evaluate optical densitometry as a method of measuring the periprosthetic bone density of the tibial platform in total knee replacement using serial dual-energy X-ray absorptiometry (DXA) as the reference test. Methods 30 patients who underwent a cemented total knee replacement were followed up for over 2 years. Standard radiographs of the knee were obtained at 12 and 24 months. These were photographed with a digital camera and enhanced with image processing software. A DXA scan was performed at the same time as the reference method. 3 regions of interest were defined tinder the tibial plateau (medial, lateral and stem positions). Results After 24 months of follow-up there was a significant decrease in density in the 3 regions, both with the optical and DXA methods. The concordance between methods was studied using Bland and Altman plots, Cronbach's alpha and intraclass correlation coefficients resulted in values from 0.72 to 0.87, depending on the region and the follow-tip time. Interpretation Quantification of optical density values with a standardized measurement system on conventional radiographs is a reliable and efficient method of determining the bone mineral density.
引用
收藏
页码:791 / 795
页数:5
相关论文
共 17 条
[1]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]
Digital image analysis: improving accuracy and reproducibility of radiographic measurement [J].
Bould, M ;
Barnard, S ;
Learmonth, ID ;
Cunningham, JL ;
Hardy, JRW .
CLINICAL BIOMECHANICS, 1999, 14 (06) :434-437
[3]
ACCURACY OF DEXA MEASUREMENT OF BONE-MINERAL DENSITY AFTER TOTAL HIP-ARTHROPLASTY [J].
COHEN, B ;
RUSHTON, N .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (03) :479-483
[4]
EWALD FC, 1989, CLIN ORTHOP RELAT R, P9
[5]
Rapid small-animal dual-energy X-ray absorptiometry using digital radiography [J].
Holdsworth, DW ;
Thornton, MM ;
Drost, D ;
Watson, PH ;
Fraher, LJ ;
Hodsman, AB .
JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 (12) :2451-2457
[6]
Changes in bone mineral density of the proximal femur after total knee arthroplasty [J].
Ishii, Y ;
Yagisawa, K ;
Ikezawa, Y .
JOURNAL OF ARTHROPLASTY, 2000, 15 (04) :519-522
[7]
Periprosthetic bone remodelling after total knee arthroplasty: early assessment by dual energy X-ray absorptiometry [J].
Karbowski, A ;
Schwitalle, M ;
Eckardt, A ;
Heine, J .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1999, 119 (5-6) :324-326
[8]
Kolbeck S, 1999, CLIN ORTHOP RELAT R, P221
[9]
LEVITZ CL, 1995, CLIN ORTHOP RELAT R, P68
[10]
Changes in bone mineral density at the proximal tibia after total knee arthroplasty: A 2-year follow-up of 28 knees using dual energy x-ray absorptiometry [J].
Li, MG ;
Nilsson, KG .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2000, 18 (01) :40-47