Quantitation of polysorbate 20 in protein solutions using mixed-mode chromatography and evaporative light scattering detection

被引:69
作者
Hewitt, Daniel [1 ]
Zhang, Taylor [1 ]
Kao, Yung-Hsiang [1 ]
机构
[1] Genentech Inc, Prot Analyt Chem, San Francisco, CA 94080 USA
关键词
Polysorbate; Mixed-mode chromatography; Evaporative light scattering detection; Protein; Sample preparation;
D O I
10.1016/j.chroma.2008.11.017
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An HPLC assay requiring no complex sample preparation for the measurement of polysorbate 20 in protein solutions was developed. An on-off chromatography technique was employed involving a mixed-mode stationary phase (Waters Oasis MAX, mixed-mode anion-exchange and reversed-phase sorbent) to quantify polysorbate 20 in solutions containing >100 mg/mL of protein. With 2% formic acid mobile phase, proteins are typically positive charged and are not retained because of electrostatic repulsions from the quaternary amine in the mixed-mode resin. Other formulation components elute in void volume because of their hydrophilicity. Hydrophobic polysorbate 20 is retained, eluted with a step gradient and quantified as a single peak using an evaporative light scattering detector. The performance of the assay is evaluated according to International Conference on Harmonisation (ICH) guidelines and shown to be suitable for polysorbate quantitation. Accuracy (96-108%) and repeatability (2.3% RSD) were demonstrated using protein samples spiked with polysorbate 20. This method was used to accurately measure polysorbate 20 in at least 25 different protein solutions spanning a wide range of formulations. Although the majority of the data reported here target polysorbate 20, this methodology can also be used to assay other common non-ionic surfactants such as polysorbate 80, Brij, Igepal, and Triton X-100. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:156 / 160
页数:5
相关论文
共 17 条
[1]  
Ayorinde FO, 2000, RAPID COMMUN MASS SP, V14, P2116, DOI 10.1002/1097-0231(20001130)14:22<2116::AID-RCM142>3.0.CO
[2]  
2-1
[3]  
BEVINAKATTI HS, 1999, DESIGN SELECTION PER, P3
[4]  
BHARDWAJ S, 1997, LCGC, V17, P354
[5]   Functionalization of divinylbenzene/N-vinylpyrrolidone copolymer particles:: Ion exchangers for solid phase extraction [J].
Brousmiche, Darryl W. ;
O'Gara, John E. ;
Walsh, Daniel P. ;
Lee, Peter J. ;
Iraneta, Pamela C. ;
Trammell, Brian C. ;
Xu, Yuehong ;
Mallet, Claude R. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1191 (1-2) :108-117
[6]   SEMIPERMEABLE-SURFACE REVERSED-PHASE MEDIA FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DESILETS, CP ;
ROUNDS, MA ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1991, 544 (1-2) :25-39
[7]   High-performance liquid chromatographic determination of polysorbate 80 in pharmaceutical suspensions [J].
Hu, M ;
Niculescu, M ;
Zhang, XM ;
Hui, A .
JOURNAL OF CHROMATOGRAPHY A, 2003, 984 (02) :233-236
[8]   Validation of a shielded-hydrophobic-phase high-performance liquid chromatography method for the determination of residual methotrexate in recombinant protein biopharmaceuticals [J].
Huang, MM ;
Penn, L ;
Bongers, J ;
Burman, S .
JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) :303-309
[9]  
KERWIN B, 2007, J PHARM SCI, V96, P1
[10]   Analysis methods of polysorbate 20: A new method to assess the stability of polysorbate 20 and established methods that may overlook degraded polysorbate 20 [J].
Khossravi, M ;
Kao, YH ;
Mrsny, RJ ;
Sweeney, TD .
PHARMACEUTICAL RESEARCH, 2002, 19 (05) :634-639