Cold heat-release characteristics of phase-change emulsion by air-emulsion direct-contact heat exchange method

被引:61
作者
Inaba, H
Morita, SI
机构
[1] Department of Mechanical Engineering, Faculty of Engineering, Okayama University, Okayama 700
[2] Sunwave-Industry Inc., Saitama 338
关键词
D O I
10.1016/0017-9310(95)00291-X
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper deals with cold heat-release characteristics of the oil (tetradecane, C14H30, latent hear 229 kJ/kg, melting point 278.9 K)/water emulsion as a latent heat-storage material having a low melting point. An air-emulsion direct-contact heat exchange method was selected for the cold heat-release from the emulsion layer including solidified tetradecane. The temperature effectiveness, the sensible heat release time and the latent heat release time were measured as experimental parameters. The useful nondimensional correlation equations for those parameters were derived in terms of nondimensional emulsion layer depth, expressed the emulsion layer dimension, Reynolds number for air flow, Stefan number and heat capacity ratio.
引用
收藏
页码:1797 / 1803
页数:7
相关论文
共 6 条
[1]
INABA H, 1993, 59565 JSME, P2882
[2]
INABA H, 1993, 31 JSME CYUG SIK AR, V935, P178
[3]
INABA H, 1993, 74 JSTP, P239
[4]
INABA H, 1994, 60572 JSME, P1422
[5]
CHARACTERISTICS OF BUBBLE COLUMN WITH A SIMULTANEOUS GAS-LIQUID INJECTION NOZZLE [J].
KATO, Y ;
ISHIMARU, A ;
KADONE, H ;
MOROOKA, S .
KAGAKU KOGAKU RONBUNSHU, 1980, 6 (06) :614-620
[6]
MERSMANN A, 1982, INT CHEM ENG, V22, P16