Neutron autoradiography imaging of selective boron uptake in human metastatic tumours

被引:48
作者
Altieri, S. [1 ,2 ]
Bortolussi, S. [1 ,2 ]
Bruschi, P. [1 ]
Chiari, P. [1 ]
Fossati, F. [1 ]
Stella, S. [1 ]
Prati, U. [3 ]
Roveda, L. [3 ]
Zonta, A. [4 ]
Zonta, C. [4 ]
Ferrari, C. [4 ]
Clerici, A. [4 ]
Nano, R. [5 ]
Pinelli, T. [1 ,2 ]
机构
[1] Univ Pavia, Dept Nucl & Theoret Phys, I-27100 Pavia, Italy
[2] Natl Inst Nucl Phys, Sect Pavia, Pavia, Italy
[3] Fdn T Campanella, Canc Ctr Excellence, Unit Canc Surg, Catanzaro, Italy
[4] Univ Pavia, Dept Surg, I-27100 Pavia, Italy
[5] Univ Pavia, Dept Anim Biol, I-27100 Pavia, Italy
关键词
Neutron radiography; BNCT; Liver metastases; Boron imaging;
D O I
10.1016/j.apradiso.2008.05.007
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The ability to selectively hit the turnout cells is an essential characteristic of an anti-tumour therapy. In boron neutron capture therapy (BNCT) this characteristic is based on the selective uptake of 1013 in the tumour cells with respect to normal tissues. An important step in the BNCT planning is the measurement of the boron concentration in the tissue samples, both tumour and healthy. When the tumour is spread through the healthy tissue, as in the case of metastases, the knowledge of the different kinds of tissues in the sample being analysed is crucial. If the percentage of tumour and normal tissues cannot be evaluated, the obtained concentration is a mean value depending on the composition of the different samples being measured. In this case an imaging method that could give information both on the morphology and on the spatial distribution of boron concentration in the sample would be a fundamental support. In this paper, the results of the boron uptake analysis in the turnout and in the healthy samples taken from human livers after boron phenylalanine (BPA) infusion are shown; boron imaging was performed using neutron autoradiography. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1850 / 1855
页数:6
相关论文
共 31 条
[1]   On the calibration curve for determination of boron in tissue by quantitative neutron capture radiography [J].
Alfassi, ZB ;
Probst, TU .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (2-3) :502-507
[2]  
[Anonymous], 1986, BORON NEUTRON CAPTUR
[3]  
BARTH RF, 2005, CLIN CANCER RES, V3987, P11
[4]   SUBCELLULAR-LOCALIZATION OF P-BORONOPHENYLALANINE-DELIVERED B-10 IN THE RAT 9L GLIOSARCOMA - CRYOGENIC PREPARATION IN-VITRO AND IN-VIVO [J].
BENNETT, BD ;
MUMFORDZISK, J ;
CODERRE, JA ;
MORRISON, GH .
RADIATION RESEARCH, 1994, 140 (01) :72-78
[5]   Thermal neutron irradiation field design for boron neutron capture therapy of human explanted liver [J].
Bortolussi, S. ;
Altieri, S. .
MEDICAL PHYSICS, 2007, 34 (12) :4700-4705
[6]   Boron neutron capture therapy for glioblastoma multiforme: Interim results from the Phase I/II dose-escalation studies [J].
Chanana, AD ;
Capala, J ;
Chadha, M ;
Coderre, JA ;
Diaz, AZ ;
Elowitz, EH ;
Iwai, J ;
Joel, DD ;
Liu, HGB ;
Ma, RM ;
Pendzick, N ;
Peress, NS ;
Shady, MS ;
Slatkin, DN ;
Tyson, GW ;
Wielopolski, L .
NEUROSURGERY, 1999, 44 (06) :1182-1192
[7]  
CHIARAVIGLIO D, 1989, STRAHLENTHER ONKOL, V165, P170
[8]   The radiation biology of boron neutron capture therapy [J].
Coderre, JA ;
Morris, GM .
RADIATION RESEARCH, 1999, 151 (01) :1-18
[9]  
EDWARDS L C, 1956, Int J Appl Radiat Isot, V1, P184, DOI 10.1016/0020-708X(56)90005-9
[10]   ETCHING BEHAVIOR OF A CELLULOSE NITRATE PLASTIC DETECTOR UNDER VARIOUS ETCHING CONDITIONS [J].
ENGE, W ;
GRABISCH, K ;
BEAUJEAN, R ;
BARTHOLM.KP .
NUCLEAR INSTRUMENTS & METHODS, 1974, 115 (01) :263-270