High-throughput multi-antigen microfluidic fluorescence immunoassays

被引:103
作者
Kartalov, EP
Zhong, JF
Scherer, A
Quake, SR
Taylor, CR
Anderson, WF
机构
[1] Univ So Calif, Keck Sch Med, Dept Biochem & Mol Biol, Norris Canc Ctr, Los Angeles, CA 90033 USA
[2] CALTECH, Pasadena, CA 91125 USA
[3] Stanford Univ, Stanford, CA 94305 USA
关键词
D O I
10.2144/000112071
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Here we describe the development of a high-throughput multi-antigen microfluidic fluorescence immunoassay system. A 100-chamber polydimethylsiloxane (PDMS) chip performs up to 5 tests for each of 10 samples. In this particular study system, the specificity of detection was demonstrated, and calibration curves were produced for C-reactive protein (CRP), prostate-specific antigen (PSA), ferritin, and vascular endothelial growth factor (VEGF). The measurements show sensitivity at and below clinically normal levels (with a signal-to-noise ratio >8 at as low as 10 pM antigen concentration). The chip uses 100 nL per sample for all tests. The developed system is an important step toward derivative immunoassay applications in scientific research and "point-of-care "testing in medicine.
引用
收藏
页码:85 / 90
页数:6
相关论文
共 22 条
[1]   3D protein microarrays:: Performing multiplex immunoassays on a single chip [J].
Angenendt, P ;
Glökler, J ;
Konthur, Z ;
Lehrach, H ;
Cahill, DJ .
ANALYTICAL CHEMISTRY, 2003, 75 (17) :4368-4372
[2]   Patterned delivery of immunoglobulins to surfaces using microfluidic networks [J].
Delamarche, E ;
Bernard, A ;
Schmid, H ;
Michel, B ;
Biebuyck, H .
SCIENCE, 1997, 276 (5313) :779-781
[3]   A microarray immunoassay for simultaneous detection of proteins and bacteria [J].
Delehanty, JB ;
Ligler, FS .
ANALYTICAL CHEMISTRY, 2002, 74 (21) :5681-5687
[4]   Microfluidic ELISA: On-chip fluorescence imaging [J].
Eteshola, E ;
Balberg, M .
BIOMEDICAL MICRODEVICES, 2004, 6 (01) :7-9
[5]   Microchip separations of protein biotoxins using an integrated hand-held device [J].
Fruetel, JA ;
Renzi, RF ;
VanderNoot, VA ;
Stamps, J ;
Horn, BA ;
West, JAA ;
Ferko, S ;
Crocker, R ;
Bailey, CG ;
Arnold, D ;
Wiedenman, B ;
Choi, WY ;
Yee, D ;
Shokair, I ;
Hasselbrink, E ;
Paul, P ;
Rakestraw, D ;
Padgen, D .
ELECTROPHORESIS, 2005, 26 (06) :1144-1154
[6]  
Gilbert Hugh C, 2004, Int Anesthesiol Clin, V42, P73, DOI 10.1097/00004311-200404220-00007
[7]   A miniaturized, parallel, serially diluted immunoassay for analyzing multiple antigens [J].
Jiang, XY ;
Ng, JMK ;
Stroock, AD ;
Dertinger, SKW ;
Whitesides, GM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (18) :5294-5295
[8]   Label-free reading of microarray-based immunoassays with surface plasmon resonance imaging [J].
Kanda, V ;
Kariuki, JK ;
Harrison, DJ ;
McDermott, MT .
ANALYTICAL CHEMISTRY, 2004, 76 (24) :7257-7262
[9]   Solving the "world-to-chip" interface problem with a microfluidic matrix [J].
Liu, J ;
Hansen, C ;
Quake, SR .
ANALYTICAL CHEMISTRY, 2003, 75 (18) :4718-4723
[10]  
Maeda K, 1996, CANCER, V77, P858, DOI 10.1002/(SICI)1097-0142(19960301)77:5<858::AID-CNCR8>3.0.CO