Surface Laplacian of Central Scalp Electrical Signals is Insensitive to Muscle Contamination

被引:49
作者
Fitzgibbon, Sean P. [4 ,5 ]
Lewis, Trent W. [4 ]
Powers, David M. W. [4 ]
Whitham, Emma W. [1 ,3 ]
Willoughby, John O. [1 ,2 ,3 ]
Pope, Kenneth J. [4 ]
机构
[1] Flinders Univ S Australia, Dept Neurol, Adelaide, SA 5001, Australia
[2] Flinders Univ S Australia, Ctr Neurosci, Adelaide, SA 5001, Australia
[3] Med Ctr, Adelaide, SA 5001, Australia
[4] Flinders Univ S Australia, Sch Comp Sci Engn & Math, Adelaide, SA 5001, Australia
[5] Flinders Univ S Australia, Sch Med, Adelaide, SA 5001, Australia
基金
英国医学研究理事会; 澳大利亚研究理事会; 英国惠康基金;
关键词
Brain; electroencephalographic ( EEG); electromyographic (EMG); paralysis; EEG; EMG; RECORDINGS; CORTEX; PHASE;
D O I
10.1109/TBME.2012.2195662
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this paper was to investigate the effects of surface Laplacian processing on gross and persistent electromyographic (EMG) contamination of electroencephalographic (EEG) signals in electrical scalp recordings. We made scalp recordings during passive and active tasks, on awake subjects in the absence and in the presence of complete neuromuscular blockade. Three scalp surface Laplacian estimators were compared to left ear and common average reference (CAR). Contamination was quantified by comparing power after paralysis (brain signal, B) with power before paralysis (brain plus muscle signal, B+M). Brain: Muscle (B: M) ratios for the methods were calculated using B and differences in power after paralysis to represent muscle (M). There were very small power differences after paralysis up to 600 Hz using surface Laplacian transforms (B: M > 6 above 30 Hz in central scalp leads). Scalp surface Laplacian transforms reduce muscle power in central and pericentral leads to less than one sixth of the brain signal, two to three times better signal detection than CAR. Scalp surface Laplacian transformations provide robust estimates for detecting high-frequency (gamma) activity, for assessing electrophysiological correlates of disease, and also for providing a measure of brain electrical activity for use as a standard in the development of brain/muscle signal separation methods.
引用
收藏
页码:4 / 9
页数:6
相关论文
共 21 条
[1]  
[Anonymous], 2005, Electric fields of the brain: The neurophysics of eeg
[2]   Increased gamma-range activity in human sensorimotor cortex during performance of visuomotor tasks [J].
Aoki, F ;
Fetz, EE ;
Shupe, L ;
Lettich, E ;
Ojemann, GA .
CLINICAL NEUROPHYSIOLOGY, 1999, 110 (03) :524-537
[3]   Oscillatory gamma activity in humans: a possible role for object representation [J].
Bertrand, O ;
Tallon-Baudry, C .
INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2000, 38 (03) :211-223
[4]  
Buzsaki G., 2006, RHYTHMS BRAIN
[5]   Enhanced detection of artifacts in EEG data using higher-order statistics and independent component analysis [J].
Delorme, Arnaud ;
Sejnowski, Terrence ;
Makeig, Scott .
NEUROIMAGE, 2007, 34 (04) :1443-1449
[6]   TEMPORAL CODING IN THE VISUAL-CORTEX - NEW VISTAS ON INTEGRATION IN THE NERVOUS-SYSTEM [J].
ENGEL, AK ;
KONIG, P ;
KREITER, AK ;
SCHILLEN, TB ;
SINGER, W .
TRENDS IN NEUROSCIENCES, 1992, 15 (06) :218-226
[7]   Removal of EEG noise and artifact using blind source separation [J].
Fitzgibbon, S. P. ;
Powers, D. M. W. ;
Pope, K. J. ;
Clark, C. R. .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2007, 24 (03) :232-243
[8]   EMG contamination of EEG: spectral and topographical characteristics [J].
Goncharova, II ;
McFarland, DJ ;
Vaughan, TM ;
Wolpaw, JR .
CLINICAL NEUROPHYSIOLOGY, 2003, 114 (09) :1580-1593
[9]   ONLINE TRANSFORMATION OF EEG SCALP POTENTIALS INTO ORTHOGONAL SOURCE DERIVATIONS [J].
HJORTH, B .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1975, 39 (05) :526-530
[10]  
Kumar Shrawan, 2003, Spine J, V3, P339, DOI 10.1016/S1529-9430(03)00077-9