Opacification of the urinary tract in portal venous spiral CT without delayed scans

被引:2
作者
Dinkel, HP [1 ]
Moll, R [1 ]
Fieger, M [1 ]
Knüpffer, J [1 ]
Schindler, G [1 ]
机构
[1] Univ Wurzburg, Dept Diagnost Radiol, D-97080 Wurzburg, Germany
关键词
abdominal spiral CT; renal opacification; liver attenuation; lesion detection;
D O I
10.1007/s003300050888
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In portal venous spiral CT there is no visible renal contrast excretion within the usual period of scanning. To opacify collecting systems additional delayed scanning is required. We administered an ex; tra pre-dose of contrast medium before the main portal venous bolus in order to opacify the urinary tract and studied its effects on liver attenuation. In 32 patients examined first by non-contrast spiral CT 20 mi of a non-ionic IV CM were injected. Five minutes later, orientating cuts in the liver and along the urinary tract were obtained. Immediately thereafter, a 120- ml bolus was administered at 3 ml/s for portal venous phase helical CT (60-s delay craniocaudad). The quality of renal excretion was graded visually (excellent, fair, poor, none). Hepatic attenuation measurements were performed at comparable regions of interest. In all patients 20 ml CM opacified the renal pelvis after 5 min. Depiction of the ureters was excellent in 14, fair in 11 and poor or none in 7 cases. There was little effect on mean hepatic attenuation by the 20-ml pre-bolus after 5 min: mean enhancement 2.3 HU (range -0.6 to 7.8 PIU). Mean hepatic enhance ment after the 120-ml portal venous bolus ranged between 23.6 and 74.1 HU (mean 51.5 HU). When opacification of the urinary tract is necessary, pre-administration of a 20-mi bolus 5 min before portal venous scanning may save an extra delayed spiral. The effects on hepatic enhancement are negligible.
引用
收藏
页码:1579 / 1585
页数:7
相关论文
共 34 条
[1]   CONTRAST-MEDIA AS MARKERS FOR GLOMERULAR-FILTRATION - A PHARMACOKINETIC COMPARISON OF 4 AGENTS [J].
BACK, SE ;
KRUTZEN, E ;
NILSSONEHLE, P .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1988, 48 (03) :247-253
[2]   UNDERSTANDING AND OPTIMIZING USE OF CONTRAST MATERIAL FOR CT OF THE LIVER [J].
BARON, RL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (02) :323-331
[3]   COMPARISON OF CONTRAST-MEDIA INJECTION RATES AND VOLUMES FOR HEPATIC DYNAMIC INCREMENTED COMPUTED-TOMOGRAPHY [J].
BERLAND, LL ;
LEE, JY .
INVESTIGATIVE RADIOLOGY, 1988, 23 (12) :918-922
[4]  
BOSNIAK MA, 1986, RADIOLOGY, V158, P1
[5]   CONTRAST ENHANCEMENT IN ABDOMINAL CT - BOLUS VS INFUSION [J].
BURGENER, FA ;
HAMLIN, DJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (02) :351-358
[6]   RENAL MASSES - ASSESSMENT OF CORTICOMEDULLARY-PHASE AND NEPHROGRAPHIC-PHASE CT SCANS [J].
COHAN, RH ;
SHERMAN, LS ;
KOROBKIN, M ;
BASS, JC ;
FRANCIS, IR .
RADIOLOGY, 1995, 196 (02) :445-451
[7]   CONTRAST ENHANCEMENT PHARMACOKINETICS OF 6 IONIC AND NON-IONIC CONTRAST-MEDIA [J].
DEAN, PB ;
KIVISAARI, L ;
KORMANO, M .
INVESTIGATIVE RADIOLOGY, 1983, 18 (04) :368-374
[8]   HEPATIC CT CONTRAST ENHANCEMENT - EFFECT OF DOSE, DURATION OF INFUSION, AND TIME ELAPSED FOLLOWING INFUSION [J].
DEAN, PB ;
VIOLANTE, MR ;
MAHONEY, JA .
INVESTIGATIVE RADIOLOGY, 1980, 15 (02) :158-161
[9]  
DESPOPOULOS A, 1983, COLOR ATLAS PHYSL
[10]  
DINKEL HP, 1997, EUR RADIOL, V7, P794