X-ray computed laminography:: an approach of computed tomography for applications with limited access

被引:89
作者
Gondrom, S [1 ]
Zhou, J [1 ]
Maisl, M [1 ]
Reiter, H [1 ]
Kröning, M [1 ]
Arnold, W [1 ]
机构
[1] Univ Saarbrucken, Fraunhofer Inst Nondestruct Testing, D-66123 Saarbrucken, Germany
关键词
D O I
10.1016/S0029-5493(98)00319-7
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Computed laminography (CL) is an image forming method of X-ray testing that yields images of object slices by a simple linear translation of the object relative to the tube-detector system. No relative movement of the X-ray tube to the detector is needed and in contrast to classical laminography all object layers can be obtained by one scan. Moreover CL turns out to be equivalent to a computed tomography (CT) with a limited angular region, which allows the reconstruction of object slices using slightly modified CT algorithms, resulting in a higher resolution compared with simple tomosynthesis in the case of classical laminography. (C) 1999 Elsevier Science S.A. An rights reserved.
引用
收藏
页码:141 / 147
页数:7
相关论文
共 12 条
[1]  
ADAMS J, 1991, SPIE INTEGRATED CIRC, V1464, P484
[2]  
EWERT U, 1994, INT S COMP TOM IND A, P148
[3]  
FEISTE K, 1994, INT S COMP TOM IND A, P160
[4]  
*HEWL PACK, 1995, PCBA XRAY INSP
[5]   COMPUTERIZED TRANSVERSE AXIAL SCANNING (TOMOGRAPHY) .1. DESCRIPTION OF SYSTEM [J].
HOUNDFIELD, GN .
BRITISH JOURNAL OF RADIOLOGY, 1973, 46 (552) :1016-1022
[6]  
Neubauer C., 1997, IEEE Transactions on Components, Packaging & Manufacturing Technology, Part C (Manufacturing), V20, P111, DOI 10.1109/3476.622881
[7]  
Radon J., 1917, Mathematisch-Physische Klasse, V69, P262, DOI DOI 10.1109/TMI.1986.4307775
[8]  
Rowland S. W., 1979, Image reconstruction from projections. Implementation and applications, P9
[9]   Computed laminography for materials testing [J].
Zhou, J ;
Maisl, M ;
Reiter, H ;
Arnold, W .
APPLIED PHYSICS LETTERS, 1996, 68 (24) :3500-3502
[10]  
ZHOU J, 1993, 37 DGZFP, P288