Subvoxel processing: A method for reducing partial volume blurring with application to in vivo MR images of trablecular bone

被引:48
作者
Hwang, SN [1 ]
Wehrli, FW [1 ]
机构
[1] Univ Penn, Med Ctr, Dept Radiol, Lab Struct NMR Imaging, Philadelphia, PA 19104 USA
关键词
image processing; resolution enhancement; trabecular bone architecture; quantitative microimaging; partial volume blurring;
D O I
10.1002/mrm.10138
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Partial volume blurring precludes accurate measurement of structural dimensions in the limited-resolution regime In which Image voxel size is larger than the typical structural element to be resolved. Since acquiring images at increased resolution often exacts an unacceptable signal-to-noise ratio (SNR) penalty, methods to alleviate the adverse effects of partial volume blurring are instrumental for the accurate measurement of architectural parameters in applications such as predicting the mechanical competence of trabecular bone networks. In the current work, a novel post-processing method, referred to as "subvoxel processing," is described for increasing apparent image resolution. The method is applicable to volumes of interest containing material phases of two discrete signal intensites. The principal strategy consists of subdividing voxels and assigning voxel intensities to each subvoxel on the basis of local neighborhood criteria and strict mass conservation. In the current work, the method's accuracy has been evaluated using microcomputed tomography images (22 x 22 x 22 mum(3) voxel size) of human trabecular bone. The results demonstrate that subvoxel processing is significantly more accurate than trilinear interpolation in decreasing apparent voxel size, especially in the presence of noise. In addition, the method's effectiveness is illustrated with MR images of human trabecular bone acquired in vivo at 137 x 137 x 350 mum(3) voxel size. The subvoxel-processed images are shown to have architectural features characteristic of images acquired at higher spatial resolution. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:948 / 957
页数:10
相关论文
共 21 条
[1]   Topological analysis of trabecular bone MR images [J].
Gomberg, BR ;
Saha, PK ;
Song, HK ;
Hwang, SN ;
Wehrli, FW .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (03) :166-174
[2]   In vivo assessment of trabecular bone structure at the distal radius from high-resolution magnetic resonance images [J].
Gordon, CL ;
Webber, CE ;
Christoforou, N ;
Nahmias, C .
MEDICAL PHYSICS, 1997, 24 (04) :585-593
[3]   THE RICIAN DISTRIBUTION OF NOISY MRI DATA [J].
GUDBJARTSSON, H ;
PATZ, S .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) :910-914
[4]   Direct three-dimensional morphometric analysis of human cancellous bone:: Microstructural data from spine, femur, iliac crest, and calcaneus [J].
Hildebrand, T ;
Laib, A ;
Müller, R ;
Dequeker, J ;
Rüegsegger, P .
JOURNAL OF BONE AND MINERAL RESEARCH, 1999, 14 (07) :1167-1174
[5]  
Hwang SN, 1999, INT J IMAG SYST TECH, V10, P186, DOI 10.1002/(SICI)1098-1098(1999)10:2<186::AID-IMA9>3.0.CO
[6]  
2-7
[7]  
HWANG SN, 2000, P INT SOC MAGN RES M, P2134
[8]  
HWANG SN, 2001, P 9 ANN M ISMRM GLAS
[9]  
Laib A, 1998, Technol Health Care, V6, P329
[10]   In vivo high resolution MRI of the calcaneus: Differences in trabecular structure in osteoporosis patients [J].
Link, TM ;
Majumdar, S ;
Augat, P ;
Lin, JC ;
Newitt, D ;
Lu, Y ;
Lane, NE ;
Genant, HK .
JOURNAL OF BONE AND MINERAL RESEARCH, 1998, 13 (07) :1175-1182