Indoor particulate matter of outdoor origin: Importance of size-dependent removal mechanisms

被引:325
作者
Riley, WJ
McKone, TE
Lai, ACK
Nazaroff, WW
机构
[1] EO Lawrence Berkeley Natl Lab, Environm Energy Technol Div, Indoor Environm Dept, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Sch Publ Hlth, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Dept Civil & Environm Engn, Berkeley, CA 94720 USA
关键词
D O I
10.1021/es010723y
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Adverse human health effects have been observed to correlate with levels of outdoor particulate matter (PM), even though most human exposure to PM of outdoor origin occurs indoors. In this study, we apply a model and empirical data to explore the indoor PM levels of outdoor origin for two major building types: offices and residences. Typical ventilation rates for each building type are obtained from the literature. Published data are combined with theoretical analyses to develop representative particle penetration coefficients, deposition loss rates, and ventilation-system filter efficiencies for a broad particle size range (i.e., 0.001-10 mum). We apply archetypal outdoor number, surface area, and mass PM size distributions for both urban and rural airsheds. We also use data on mass-weighted size distributions for specific chemical constituents of PM: sulfate and elemental carbon. Predictions of the size-resolved indoor proportion of outdoor particles (IPOP) for various conditions and ambient particle distributions are then computed. The IPOP depends strongly on the ambient particle size distribution, building type and operational parameters, and PM metric. We conclude that an accurate determination of exposure to particles of ambient origin requires explicit consideration of how removal processes in buildings vary with particle size.
引用
收藏
页码:200 / 207
页数:8
相关论文
共 48 条
[1]   Relative contribution of outdoor and indoor particle sources to indoor concentrations [J].
Abt, E ;
Suh, HH ;
Catalano, P ;
Koutrakis, P .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (17) :3579-3587
[2]   INDOOR-OUTDOOR RELATIONSHIPS FOR AIRBORNE PARTICULATE MATTER OF OUTDOOR ORIGIN [J].
ALZONA, J ;
COHEN, BL ;
RUDOLPH, H ;
JOW, HN ;
FROHLIGER, JO .
ATMOSPHERIC ENVIRONMENT, 1979, 13 (01) :55-60
[3]  
[Anonymous], RADON ITS DECAY PROD
[4]  
ASHRAE, 1993, ASHRAE Handbook, Fundamentals, VI-P
[5]   STABLE TRACER AEROSOL DEPOSITION MEASUREMENTS IN A TEST CHAMBER [J].
BYRNE, MA ;
GODDARD, AJH ;
LANGE, C ;
ROED, J .
JOURNAL OF AEROSOL SCIENCE, 1995, 26 (04) :645-653
[6]  
Cullen A.C., 1999, Probabilistic Techniques in Expose Assessment: A Handbook for Dealing with Variability and Uncertainty in Models and Inputs
[7]  
Finlayson-Pitts B. J., 2000, Chemistry of the Upper and Lower Atmosphere
[8]   Size specific indoor aerosol deposition measurements and derived I/O concentrations ratios [J].
Fogh, CL ;
Byrne, MA ;
Roed, J ;
Goddard, AJH .
ATMOSPHERIC ENVIRONMENT, 1997, 31 (15) :2193-2203
[9]   FRACTIONAL AEROSOL FILTRATION EFFICIENCY OF IN-DUCT VENTILATION AIR CLEANERS [J].
HANLEY, JT ;
ENSOR, DS ;
SMITH, DD ;
SPARKS, LE .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (03) :169-178
[10]  
Hinds W., 1999, Aerosol Technology: Properties, Behavior, and Measurement of Airborne Particles, DOI 10.1016/0021-8502(83)90049-6