Effects of gold coating of coronary stents on neointimal proliferation following stent implantation

被引:35
作者
vom Dahl, J
Haager, PK
Grube, E
Gross, M
Beythien, C
Kromer, EP
Cattelaens, N
Hamm, CW
Hoffmann, R
Reineke, T
Klues, HG
机构
[1] Univ Klinikum RWTH Aachen, Med Klin 1, Aachen, Germany
[2] Krankenhaus Siegburg GmbH, Kardiol Klin, Siegburg, Germany
[3] Univ Klinikum Charite, Klin Kardiol, Berlin, Germany
[4] Univ Hamburg, Klinikum Eppendorf, Abt Kardiol, Med Kem & Poliklin, Hamburg, Germany
[5] Klinikum Univ Regensburg, Klin & Poliklin Innere Med 2, Regensburg, Germany
[6] Univ Cologne, Inst Stat & Biometrie, Cologne, Germany
关键词
D O I
10.1016/S0002-9149(02)02188-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Experimental studies suggest a reduced neointimal tissue proliferation in vascular stainless steel stents coated with gold. This prospective multicenter trial evaluated the impact of gold coating on neointimal tissue proliferation in patients undergoing elective stent implantation. The primary end point was the in-stent tissue proliferation measured by intravascular ultrasound at 6 months comparing stents of identical design with or without gold coating (Inflow). Two hundred four patients were randomized to receive uncoated (group A, n = 101) or coated (group B, n = 103) stents. Baseline parameters did not differ between the groups. Stent length and balloon size were comparable, whereas inflation pressure was slightly higher in group A (14 +/- 3 vs, 13 +/- 3 atm, p = 0.013). Procedural success was similar (A, 97%; B, 96%). The acute angiographic result was better for group B (remaining stenosis 4 +/- 12% vs 10 +/- 11%, p = 0.002). Six-month examinations revealed more neointimal proliferation in group B. By Ultrasound, the neointimal volume within the stent was 47 +/- 25 versus 41 +/- 23 mm(3) (p = 0.04), with a ratio of neointimal volume-to-stent volume of 0.45 +/- 0.12 versus 0.40 +/- 0.12 (p = 0.003). The angiographic minimal luminal diameter was smaller in group B (1.47 +/- 0.57 vs 1.69 +/- 0.70 mm, p = 0.04), with a higher late luminal loss of 1.17 +/- 0.51 versus 0.82 +/- 0.56 mm (p = 0.001). Thus, gold coating of the tested stent type resulted in more neointimal tissue proliferation. (C) 2002 by Excerpta Medica, Inc.
引用
收藏
页码:801 / 805
页数:5
相关论文
共 21 条
  • [1] Alt E, 1998, HDB CORONARY STENTS, P265
  • [2] Influence of "diamond-like" and gold coating on platelet activation:: A flow cytometry analysis in a pulsed floating model
    Beythien, C
    Gutensohn, K
    Kühnl, P
    Hamm, CW
    Alt, E
    Terres, W
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 413A - 413A
  • [3] Cremonesi A, 2000, J INVASIVE CARDIOL, V12, P225
  • [4] Edelman ER, 2001, CIRCULATION, V103, P429
  • [5] Fischell TA, 2000, J INVASIVE CARDIOL, V12, P233
  • [6] QUANTITATIVE CORONARY ANGIOGRAPHY (QCA) IN INTERVENTIONAL CARDIOLOGY - CLINICAL-APPLICATION OF QCA MEASUREMENTS
    FOLEY, DP
    ESCANED, J
    STRAUSS, BH
    DIMARIO, C
    HAASE, J
    KEANE, D
    HERMANS, WRM
    RENSING, BJ
    DEFEYTER, PJ
    SERRUYS, PW
    [J]. PROGRESS IN CARDIOVASCULAR DISEASES, 1994, 36 (05) : 363 - 384
  • [7] HEHRLEIN C, 1995, CORONARY ARTERY DIS, V6, P581
  • [8] Thrombogenicity of stainless steel coronary stents with a completely gold coated surface
    Herrmann, RA
    Rybnikar, A
    Resch, A
    Märkl, B
    Alt, E
    Stemberger, A
    Schömig, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 413A - 413A
  • [9] The impact of high pressure vs low pressure stent implantation on intimal hyperplasia and follow-up lumen dimensions - Results of a randomized trial
    Hoffmann, R
    Haager, P
    Mintz, GS
    Kerckhoff, G
    Schwarz, R
    Franke, A
    vom Dahl, J
    Hanrath, P
    [J]. EUROPEAN HEART JOURNAL, 2001, 22 (21) : 2015 - 2024
  • [10] Ignatius MJ, 1998, J BIOMED MATER RES, V40, P264, DOI 10.1002/(SICI)1097-4636(199805)40:2<264::AID-JBM11>3.0.CO