Prevention of islanding in grid-connected photovoltaic systems

被引:55
作者
Ropp, ME [1 ]
Begovic, M [1 ]
Rohatgi, P [1 ]
机构
[1] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
来源
PROGRESS IN PHOTOVOLTAICS | 1999年 / 7卷 / 01期
关键词
D O I
10.1002/(SICI)1099-159X(199901/02)7:1<39::AID-PIP246>3.0.CO;2-J
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 [动力工程及工程热物理]; 0820 [石油与天然气工程];
摘要
Recently there has been a resurgence of concern about islanding of grid-connected photovoltaic (PV) systems. This condition occurs when the PV system continues to energize a section of the grid after that section has been isolated from the main utility voltage source. Generally, islanding is undesirable because it poses a safety hazard to utility service personnel, and also because it can lead to asynchronous reclosure which can damage equipment. It is therefore important that PV systems incorporate methods to prevent islanding. The purpose of this paper is threefold: (1) to critically review the literature on islanding prevention methods for PV systems and discuss their strengths and shortcomings; (2) to review and analyze the islanding behavior of four converters which are prominent in the literature in order to demonstrate the implementation and effectiveness of some islanding prevention methods and (3) to introduce a new islanding prevention scheme, active frequency drift with positive feedback, which overcomes many of the shortcomings of existing schemes. It is concluded that no 'perfect' islanding prevention method yet exists, but also that many existing methods or combinations thereof work very well in practical situations. Finally, it is noted than ana investigation of what constitutes 'sufficient' islanding prevention is needed. Copyright (C) 1999 John Wiley & Sons, Ltd.
引用
收藏
页码:39 / 59
页数:21
相关论文
共 30 条
[1]
[Anonymous], P 21 IEEE PHOT SPEC
[2]
ATMARAM GH, 1985, P 15 IEEE PHOT SPEC, P1326
[3]
High impedance fault detection implementation issues [J].
Aucoin, BM ;
Jones, RH .
IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (01) :139-148
[4]
Begovic M., 1998, P 2 WORLD C PHOT EN
[5]
Practical high-impedance fault detection on distribution feeders [J].
Benner, CL ;
Russell, BD .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (03) :635-640
[6]
Best R. E., 1993, PHASE LOCKED LOOPS T
[7]
Brennan P.V., 1996, PHASE LOCKED LOOPS P
[8]
THE NEW-ENGLAND ELECTRIC PHOTOVOLTAIC SYSTEMS RESEARCH AND DEMONSTRATION PROJECT [J].
BZURA, JJ .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1990, 5 (02) :284-289
[9]
PHOTOVOLTAIC RESEARCH AND DEMONSTRATION ACTIVITIES AT NEW-ENGLAND ELECTRIC [J].
BZURA, JJ .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1995, 10 (01) :169-174
[10]
PERFORMANCE OF GRID-CONNECTED PHOTOVOLTAIC SYSTEMS ON RESIDENCES AND COMMERCIAL BUILDINGS IN NEW-ENGLAND [J].
BZURA, JJ .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1992, 7 (01) :79-82