Determination of the orientation of collagen fibers in human bone

被引:22
作者
Osaki, S [1 ]
Tohno, S
Tohno, Y
Ohuchi, K
Takakura, Y
机构
[1] Nara Med Univ, Dept Chem, Kashihara, Nara 6348521, Japan
[2] Nara Med Univ, Dept Anat, Kashihara, Nara 6348521, Japan
[3] Fukushima Med Univ, Dept Orthoped, Fukushima, Japan
[4] Nara Med Univ, Dept Orthoped, Kashihara, Nara 6348521, Japan
来源
ANATOMICAL RECORD | 2002年 / 266卷 / 02期
关键词
human bone; calcaneus; slice sample; collagen fibers; orientation;
D O I
10.1002/ar.10043
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
A human calcaneus bone, consisting of hydroxyapatite and collagen fibers, was successively sliced into samples in a direction perpendicular to the long axis of the bone and parallel to the long axis of the human lower limb. The transmitted microwave intensities of 12 GHz, reflecting the dielectric property, were measured for the slice samples using Osaki's microwave method (Tappi J., 1987; 70:105-108). The complex dielectric constant of 12 GHz of the collagen fiber film was much greater than that of hydroxyapatite disc, which demonstrated that the dielectric anisotropy observed for the sliced bone was mainly affected by the collagen fibers. The angular dependence of the transmitted microwave intensity gives the orientation angle reflecting the direction of the collagen-fiber orientation, and the degree of orientation reflecting the anisotropic property of collagen fibers. The orientation angle and the degree of orientation for the slice samples changed with changing position along the long axis of the calcaneus bone. The direction of orientation deviated to the lateral side at the heel part of the left calcaneus, and to the medial side at the middle part. The degree of orientation is relatively high at the heel part and low at the middle. Such results give a two-dimensional distribution of collagen-fiber orientation in the left calcaneus, and suggest that the direction and degree of orientation are closely related to the direction and magnitude of the stress applied to the bone, respectively. Anat Rec 266:103-107, 2002. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:103 / 107
页数:5
相关论文
共 16 条
[1]  
BACON GE, 1984, J ANAT, V139, P265
[2]  
GIERSE H, 1976, ANAT EMBRYOL, V150, P63
[3]   MEASUREMENT OF THE VELOCITY OF ULTRASOUND IN HUMAN CORTICAL BONE INVIVO - ESTIMATION OF ITS POTENTIAL VALUE IN THE DIAGNOSIS OF OSTEOPOROSIS AND METABOLIC BONE-DISEASE [J].
GREENFIELD, MA ;
CRAVEN, JD ;
HUDDLESTON, A ;
KEHRER, ML ;
WISHKO, D ;
STERN, R .
RADIOLOGY, 1981, 138 (03) :701-710
[4]  
Osaki S, 1999, ANAT REC, V254, P147, DOI 10.1002/(SICI)1097-0185(19990101)254:1<147::AID-AR18>3.0.CO
[5]  
2-I
[6]   A new microwave cavity resonator for determining molecular orientation and dielectric anisotropy of sheet materials [J].
Osaki, S .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (06) :2518-2523
[7]   EXPLANATION OF ORIENTATION PATTERNS DETERMINED FOR SHEET MATERIALS BY MEANS OF MICROWAVES [J].
OSAKI, S .
JOURNAL OF APPLIED PHYSICS, 1990, 67 (10) :6513-6519
[8]  
OSAKI S, 1987, TAPPI J, V70, P105
[9]  
OSAKI S, 1993, CELL MOL BIOL, V39, P673
[10]  
OSAKI S, 1989, TAPPI J, V72, P171