Acute electrophysiological effect of pulsed gallium-arsenide low-energy laser irradiation on isolated frog sciatic nerve

被引:15
作者
Çömelekoglu, Ü
Bagis, S
Büyükakilli, B
Sahin, G
Erdogan, C
Kanik, A
机构
[1] Univ Mersin, Dept Biophys, Mersin, Turkey
[2] Univ Mersin, Dept Phys Therapy & Rehabil, Mersin, Turkey
[3] Univ Mersin, Dept Biostat, Mersin, Turkey
关键词
electrophysiological effects; frog sciatic nerve; low-energy GaAs laser irradiation;
D O I
10.1007/s10103-002-8268-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
We evaluated the acute electrophysiological effects of low-energy pulsed laser irradiation on isolated frog sciatic nerve measured by extracellular recording technique. A pulsed gallium-arsenide (GaAs) laser (wavelength: 904 nm, pulse duration 220 ns. peak power per pulse: 27 W. spot size: 0.28 cm(2). total applied energy density: 0.005 2.5 J/cm(2)) was used for the experiment. Sixty isolated nerves were divided into six groups (n=10). each of which received a different laser dose. In each group, action potentials were recorded before laser irradiation which served as the control data. The extracellular action potentials were recorded for each combination of 1, 3, 5, 7, 10, 13 and 15 minutes of irradiation time and 4. 8, 16, 32, 64 and 128 repetition frequency by using a BIOPAC MP 100 Acquisition System Version 3.5.7 (Santa Barbara, USA). Action potential amplitude, area, duration and conduction velocity were measured. Statistical evaluation was performed using repeated measures variance analysis by SPSS 9.0. There were no statistically significant differences for action potential amplitude, area and conduction velocity among the laser groups and control data (p>0.05). The study showed that low-energy GaAs irradiation at 4-128 Hz repetition frequencies administered for irradiation times of 1-15 min generates no effect on action potential amplitude. area, duration and conduction velocity in isolated frog sciatic nerve.
引用
收藏
页码:62 / 67
页数:6
相关论文
共 20 条
[1]
ANDREW BL, 1972, EXPT PHYSL
[2]
Daube Jasper R., 1996, V46, P60
[3]
Ebert DW, 1997, LASER SURG MED, V21, P32, DOI 10.1002/(SICI)1096-9101(1997)21:1<32::AID-LSM6>3.3.CO
[4]
2-0
[5]
EFFECTS OF CLINICAL INFRARED-LASER ON SUPERFICIAL RADIAL NERVE-CONDUCTION [J].
GREATHOUSE, DG ;
CURRIER, DP ;
GILMORE, RL .
PHYSICAL THERAPY, 1985, 65 (08) :1184-1187
[6]
Katz B., 1966, NERVE MUSCLE SYNAPSE
[7]
Preliminary study of low-level laser for treatment of long-standing sensory aberrations in the inferior alveolar nerve [J].
Khullar, SM ;
Brodin, P ;
Barkvoll, P ;
Haanaes, HR .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 54 (01) :2-7
[8]
KOESTER J, 2000, PRINCIPLES NEURAL SC, P151
[9]
The relevance of pulse repetition rate and radiant exposure to the neurophysiological effects of low-intensity laser (820 nm/pulsed wave) irradiation upon skin temperature and antidromic conduction latencies in the human median nerve [J].
Lowe, AS ;
Baxter, GD ;
Walsh, DM ;
Allen, JM .
LASERS IN MEDICAL SCIENCE, 1995, 10 (04) :253-259
[10]
EFFECT OF LOW-INTENSITY LASER (830 NM) IRRADIATION ON SKIN TEMPERATURE AND ANTIDROMIC CONDUCTION LATENCIES IN THE HUMAN MEDIAN NERVE - RELEVANCE OF RADIANT EXPOSURE [J].
LOWE, AS ;
BAXTER, GD ;
WALSH, DM ;
ALLEN, JM .
LASERS IN SURGERY AND MEDICINE, 1994, 14 (01) :40-46