Effective compliance during the first 3 months of continuous positive airway pressure -: A European prospective study of 121 patients

被引:186
作者
Pépin, JL
Krieger, J
Rodenstein, D
Cornette, A
Sforza, E
Delguste, P
Deschaux, C
Grillier, V
Lévy, P
机构
[1] Univ Hosp, Dept Resp Med & Sleep Lab, Grenoble, France
[2] Univ Hosp, Sleep Disorders Unit, Strasbourg, France
[3] Univ Hosp Nancy, Resp Dept, Vandoeuvre Nancy, France
[4] Univ Catholique Louvain, Clin Univ St Luc, Resp Dept, B-1200 Brussels, Belgium
[5] Nellcor Puritan Bennett FD, Nancy Les Villers, France
[6] Univ Grenoble 1, PRETA Lab, UMR CNRS 5525, Dept Physiol,Fac Med, Grenoble, France
关键词
D O I
10.1164/ajrccm.160.4.9802027
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Effective compliance (time spent at the effective pressure) with nasal CPAP in obstructive sleep apnea has been reported to be poor. The aim of our study was to evaluate effective compliance in a large European multicenter study. One hundred twenty-one consecutive newly treated patients (initial apnea-hypopnea index [AHI] = 62.0 +/- 29.5/h, AHI under CPAP = 6.4 +/- 8.1/h, CPAP pressure = 8.7 +/- 2.6 cm H2O, BMI = 33.1 +/- 6.8 kg/m(2)) were randomly allocated to a group with (MC+) (n = 58) or without (MC-) (n = 63) a control unit measuring effective compliance at 1, 2 and 3 mo, which was compared with the built-in time counter data. MC+ data were 94 +/- 10, 98 +/- 5, and 96 +/- 9% of counter data at 1, 2, and 3 mo, respectively. Using criteria of regular use already reported in the literature (at least 4 h of nCPAP per day of use and nCPAP administered more than 70% of the days) we found 77, 82, and 79% compliant patients at 1, 2, and 3 mo, respectively, 79% of the patients meeting these criteria each month. Although there were no pulmonary functions or polysomnographic differences between the two subgroups, the compliant patients did report a greater improvement in minor symptoms. We found a close correlation between effective use of CPAP and the machine run time. The main result of our study was a higher effective compliance than previously reported, approximately 80% of the patients being regular users versus 46% in a previously published study. This may result from different technical and medical follow-up.
引用
收藏
页码:1124 / 1129
页数:6
相关论文
共 28 条
[1]   PATIENT COMPLIANCE WITH INHALED MEDICATION - DOES COMBINING BETA-AGONISTS WITH CORTICOSTEROIDS IMPROVE COMPLIANCE [J].
BOSLEY, CM ;
PARRY, DT ;
COCHRANE, GM .
EUROPEAN RESPIRATORY JOURNAL, 1994, 7 (03) :504-509
[2]   Compliance with nasal CPAP can be improved by simple interventions [J].
Chervin, RD ;
Theut, S ;
Bassetti, C ;
Aldrich, MS .
SLEEP, 1997, 20 (04) :284-289
[3]  
COCHRANE GM, 1995, EUR RESPIR REV, V5, P116
[4]  
DICKINS QS, 1991, OP TECH OTOLARYNGOL, V2, P91
[5]  
ENGELMAN HM, 1994, LANCET, V343, P572
[6]   COMPLIANCE WITH CPAP THERAPY IN PATIENTS WITH THE SLEEP APNOEA/HYPOPNOEA SYNDROME [J].
ENGLEMAN, HM ;
MARTIN, SE ;
DOUGLAS, NJ .
THORAX, 1994, 49 (03) :263-266
[7]   THE EFFECT OF POSITIVE REINFORCEMENT ON HOURLY COMPLIANCE IN NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE USERS WITH OBSTRUCTIVE SLEEP-APNEA [J].
FLETCHER, EC ;
LUCKETT, RA .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 143 (05) :936-941
[9]   Residual effect of nCPAP applied for part of the night in patients with obstructive sleep apnoea [J].
Hers, V ;
Liistro, G ;
Dury, M ;
Collard, P ;
Aubert, G ;
Rodenstein, DO .
EUROPEAN RESPIRATORY JOURNAL, 1997, 10 (05) :973-976
[10]   TREATMENT OF OBSTRUCTIVE SLEEP-APNEA WITH NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE - PATIENT COMPLIANCE, PERCEPTION OF BENEFITS, AND SIDE-EFFECTS [J].
HOFFSTEIN, V ;
VINER, S ;
MATEIKA, S ;
CONWAY, J .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1992, 145 (04) :841-845