DNA extraction using a tetramethyl orthosilicate-grafted photopolymerized monolithic solid phase

被引:63
作者
Wen, J
Guillo, C
Ferrance, JP
Landers, JP [1 ]
机构
[1] Univ Virginia, Dept Chem, Charlottesville, VA 22904 USA
[2] Univ Virginia, Dept Mol Physiol, Charlottesville, VA 22904 USA
[3] Univ Virginia, Dept Biol Phys, Charlottesville, VA 22904 USA
[4] Univ Virginia, Hlth Sci Ctr, Dept Pathol, Charlottesville, VA 22908 USA
关键词
D O I
10.1021/ac051796t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel high-capacity, high-efficiency DNA extraction method is described using a photopolymerized silica-based monolithic column in a fused-silica capillary. Development involved investigation of the composition of the sol-gel monomer, fabrication conditions, and surface modifications in order to optimize the binding capacity. Extraction capacity and efficiency with the 3-(trimethoxysilyl)propyl methacrylate (TMSPM) monolith formulations fabricated in capillaries were investigated using a simple three-step procedure consisting of sample loading, washing of the solid phase, and elution of the DNA using a low ionic strength Tris buffer at pH 8. Once the TMSPM monomer concentration was optimized to yield a monolith with maximum test stability (robustness) and minimum back pressure, the monolith surface was modified by the grafting of tetramethyl orthosilicate (TMOS) for increased DNA binding capacity. After the examination of a variety of TMOS concentrations, 85% v/v TMOS was found to be optimal for DNA extraction without any obvious changes to the monolith structure. The reduction of time allowed for TMSPM hydrolysis prior to UV polymerization from 20 to 5 min led to a lower back pressure of the monolith, enabling better TMOS derivatization and therefore higher binding capacity. Minimal buffer volume (as low as 1 mu L) was required to elute DNA from the solid phase, providing a DNA concentrating effect potentially important for downstream processes. While experimentation employed monolithic columns that were 12 cm in length, reduction of the length to 2 cm still allowed for a DNA binding capacity of at least 100 ng of prepurified human genomic DNA and extraction efficiencies greater than 85%. Extraction of low sample volumes (submicroliter) of human whole blood were successfully performed, with extraction efficiencies from the 2-cm monolithic column higher than those obtained from a commercial DNA extraction kit. These results position this novel matrix as an attractive alternative for solid-phase extraction of DNA and other biologically active molecules in microscale devices.
引用
收藏
页码:1673 / 1681
页数:9
相关论文
共 47 条
[1]   Characterization of methacrylate monoliths for purification of DNA molecules [J].
Bencina, M ;
Podgornik, A ;
Strancar, A .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (10-11) :801-810
[2]  
BIENVENUE JM, IN PRESS J FORENSIC
[3]   RAPID AND SIMPLE METHOD FOR PURIFICATION OF NUCLEIC-ACIDS [J].
BOOM, R ;
SOL, CJA ;
SALIMANS, MMM ;
JANSEN, CL ;
WERTHEIMVANDILLEN, PME ;
VANDERNOORDAA, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (03) :495-503
[4]   Application of short monolithic columns for fast purification of plasmid DNA [J].
Branovic, K ;
Forcic, D ;
Ivancic, J ;
Strancar, A ;
Barut, M ;
Gulija, TK ;
Zgorelec, R ;
Mazuran, R .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 801 (02) :331-337
[5]   Microchip-based purification of DNA from biological samples [J].
Breadmore, MC ;
Wolfe, KA ;
Arcibal, IG ;
Leung, WK ;
Dickson, D ;
Giordano, BC ;
Power, ME ;
Ferrance, JP ;
Feldman, SH ;
Norris, PM ;
Landers, JP .
ANALYTICAL CHEMISTRY, 2003, 75 (08) :1880-1886
[6]  
BRINKLER CJ, 1989, SOL GEL SCI
[7]   Nucleic acid purification using microfabricated silicon structures [J].
Cady, NC ;
Stelick, S ;
Batt, CA .
BIOSENSORS & BIOELECTRONICS, 2003, 19 (01) :59-66
[8]   Novel monolithic columns with templated porosity [J].
Chirica, GS ;
Remcho, VT .
JOURNAL OF CHROMATOGRAPHY A, 2001, 924 (1-2) :223-232
[9]   Rapid, automated nucleic acid probe assays using silicon microstructures for nucleic acid concentration [J].
Christel, LA ;
Petersen, K ;
McMillan, W ;
Northrup, MA .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (01) :22-27
[10]   Microfluidic chip for high efficiency DNA extraction [J].
Chung, YC ;
Jan, MS ;
Lin, YC ;
Lin, JH ;
Cheng, WC ;
Fan, CY .
LAB ON A CHIP, 2004, 4 (02) :141-147