Implantable cardioverter-defibrillator lead failure: how weak is the link?

被引:5
作者
Brinker, Jeffrey A. [1 ]
机构
[1] Johns Hopkins Med Inst, Baltimore, MD 21205 USA
来源
NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE | 2008年 / 5卷 / 12期
关键词
arrhythmias; implantable cardioverter-defibrillator; lead failure; sudden cardiac death;
D O I
10.1038/ncpcardio1367
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
The implantable cardioverter-defibrillator (ICD) has been shown to decrease the risk of sudden cardiac death in patients when used for primary and secondary prevention. These devices are being used more frequently as indications for primary prevention broaden, and attention has become increasingly focused on complications caused by lead failure. A report using data from a large registry revealed that the cumulative incidence of lead malfunction that necessitated surgical revision of the ICD lead system was 2.5% over 5 years. A strategy to deal with failed leads by the implantation of new pace-sense leads or high-voltage leads resulted in a 20% malfunction recurrence rate at 5 years. Defibrillator leads have been termed the 'weakest link' in the ICD system. Further efforts from manufacturers, regulators, and implanting physicians are required to understand and address the causes of lead failure.
引用
收藏
页码:758 / 759
页数:2
相关论文
共 9 条
[1]
Trends in hospitalization for the implantation of cardioverter-defibrillators in the United States, 1990-2005 [J].
Brown, David W. ;
Croft, Janet B. ;
Greenlund, Kurt J. ;
Mensah, George A. ;
Giles, Wayne H. .
AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (12) :1753-1755
[2]
Inappropriate implantable cardioverter-defibrillator shocks in MADIT II [J].
Daubert, James P. ;
Zareba, Wojciech ;
Cannom, David S. ;
McNitt, Scott ;
Rosero, Spencer Z. ;
Wang, Paul ;
Schuger, Claudio ;
Steinberg, Jonathan S. ;
Higgins, Steven L. ;
Wilber, David J. ;
Klein, Helmut ;
Andrews, Mark L. ;
Hall, W. Jackson ;
Moss, Arthur J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (14) :1357-1365
[3]
Necessity for surgical revision of defibrillator leads implanted long-term causes and management [J].
Eckstein, Jens ;
Koller, Michael T. ;
Zabel, Markus ;
Kalusche, Dietrich ;
Schaer, Beat A. ;
Osswald, Stefan ;
Sticherling, Christian .
CIRCULATION, 2008, 117 (21) :2727-2733
[4]
Deaths associated with implantable cardioverter defibrillator failure and deactivation reported in The United States Food and Drug Administration Manufacturer and User Facility Device Experience Database [J].
Hauser, RG ;
Kallinen, L .
HEART RHYTHM, 2004, 1 (04) :399-405
[5]
Failure of impedance monitoring to prevent adverse clinical events caused by fracture of a recalled high-voltage implantable cardioverter-defibrillator lead [J].
Kallinen, Linda M. ;
Hauser, Robert G. ;
Lee, Ken W. ;
Almquist, Adrian K. ;
Katsiyiannis, William T. ;
Tang, Chuen Y. ;
Melby, Daniel P. ;
Gornick, Charles C. .
HEART RHYTHM, 2008, 5 (06) :775-779
[6]
Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of > 10 years [J].
Kleemann, Thomas ;
Becker, Torsten ;
Doenges, Klaus ;
Vater, Margit ;
Senges, Jochen ;
Schneider, Steffen ;
Saggau, Werner ;
Weisse, Udo ;
Seidl, Karlheinz .
CIRCULATION, 2007, 115 (19) :2474-2480
[7]
More late perforations with the Riata™ defibrillator lead from a high-volume center:: An update on the numbers [J].
Lloyd, Michael S. ;
Shaik, M. Naushad ;
Riley, Michael ;
Langberg, Jonathan J. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (06) :784-785
[9]
TERMINATION OF MALIGNANT VENTRICULAR ARRHYTHMIAS WITH AN IMPLANTED AUTOMATIC DEFIBRILLATOR IN HUMAN-BEINGS [J].
MIROWSKI, M ;
REID, PR ;
MOWER, MM ;
WATKINS, L ;
GOTT, VL ;
SCHAUBLE, JF ;
LANGER, A ;
HEILMAN, MS ;
KOLENIK, SA ;
FISCHELL, RE ;
WEISFELDT, ML .
NEW ENGLAND JOURNAL OF MEDICINE, 1980, 303 (06) :322-324