Gramicidin-based channel systems for the detection of protein-ligand interaction

被引:37
作者
Futaki, S [1 ]
Zhang, YJ
Kiwada, T
Nakase, I
Yagami, T
Oiki, S
Sugiura, Y
机构
[1] Kyoto Univ, Inst Chem Res, Uji, Kyoto 6110011, Japan
[2] Natl Inst Hlth Sci, Div Med Devices, Setagaya Ku, Tokyo 1588501, Japan
[3] Fukui Med Univ, Dept Mol Physiol & Biophys, Fukui 9101193, Japan
关键词
artificial ion-channel; gramicidin-biotin conjugate; protein-ligand interaction; synthetic peptide;
D O I
10.1016/j.bmc.2003.06.003
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
To detect protein-ligand interaction a gramicidin-based sensor was developed. Biotin was tagged to the C-terminus of gramicidin (Gram-bio 1). The biotin-moiety, which faces the electrolyte, gave little effect on single-channel conductance. Streptavidin added to the electrolyte was detected by Gram-bio I through the monitoring channel current using the planar bilayer system. The suppression of macroscopic currents and the acceleration of their decaying time course were observed in a concentration dependent manner. In the single-channel level, however, no significant effect on the single-channel conductance and the open dwell time was observed upon addition of streptavidin. Therefore, streptavidin neither blocked the open channel nor changed the stability of the conducting dimer. Insertion of a linker between gramicidin and biotin did not change the streptavidin-sensitivity of the current reduction. We conclude that the binding of streptavidin to the Gram-bio I shifted the distribution of the complex from the membrane to the electrolyte and, thus, reduced the formation of conducting dimer of Gram-bio I in the membrane. Interaction of biotin with an anti-biotin antibody was also observed using this system, indicating that this system is applicable for the detection of protein-ligand interaction having a binding constant of similar to 10(8-9) M-1 or more. Both the adamantane-tagged gramicidin for detection of beta-cyclodextrin and the Strep Tag-II-tagged gramicidin for detection of streptavidin (binding constant: similar to 10(5) M-1 or less) failed to respond. Thus, high-affinity ligands upon tagging to gramicidin render the gramicidin-based sensor able to execute as a real-time monitoring system for protein-ligand interaction. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1343 / 1350
页数:8
相关论文
共 46 条
[1]   SYNTHETIC PEPTIDES AS MODELS FOR ION CHANNEL PROTEINS [J].
AKERFELDT, KS ;
LEAR, JD ;
WASSERMAN, ZR ;
CHUNG, LA ;
DEGRADO, WF .
ACCOUNTS OF CHEMICAL RESEARCH, 1993, 26 (04) :191-197
[2]   TETRAPHILIN - A 4-HELIX PROTON CHANNEL BUILT ON A TETRAPHENYLPORPHYRIN FRAMEWORK [J].
AKERFELDT, KS ;
KIM, RM ;
CAMAC, D ;
GROVES, JT ;
LEAR, JD ;
DEGRADO, WF .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (24) :9656-9657
[3]  
[Anonymous], ION CHANNELS PRACTIC
[4]   Polyanions decelerate the kinetics of positively charged gramicidin channels as shown by sensitized photoinactivation [J].
Antonenko, YN ;
Borisenko, V ;
Melik-Nubarov, NS ;
Kotova, EA ;
Woolley, GA .
BIOPHYSICAL JOURNAL, 2002, 82 (03) :1308-1318
[5]  
Atherton E., 1989, SOLID PHASE PEPTIDE
[6]  
BARLOS K, 1991, INT J PEPT PROT RES, V37, P513
[7]   Designed membrane channels and pores [J].
Bayley, H .
CURRENT OPINION IN BIOTECHNOLOGY, 1999, 10 (01) :94-103
[8]   Protonation of lysine residues inverts cation/anion selectivity in a model channel [J].
Borisenko, V ;
Sansom, MSP ;
Woolley, GA .
BIOPHYSICAL JOURNAL, 2000, 78 (03) :1335-1348
[9]   A biosensor that uses ion-channel switches [J].
Cornell, BA ;
BraachMaksvytis, VLB ;
King, LG ;
Osman, PDJ ;
Raguse, B ;
Wieczorek, L ;
Pace, RJ .
NATURE, 1997, 387 (6633) :580-583
[10]   PYBOP - A NEW PEPTIDE COUPLING REAGENT DEVOID OF TOXIC BY-PRODUCT [J].
COSTE, J ;
LENGUYEN, D ;
CASTRO, B .
TETRAHEDRON LETTERS, 1990, 31 (02) :205-208