Inappropriate arrhythmia detection in implantable defibrillator therapy due to oversensing of diaphragmatic myopotentials

被引:27
作者
Schulte, B [1 ]
Sperzel, J [1 ]
Carlsson, J [1 ]
Dürsch, M [1 ]
Erdogan, A [1 ]
Pitschner, HF [1 ]
Neuzner, J [1 ]
机构
[1] Kerckhoff Klin, Dept Cardiol, D-61231 Bad Nauheim, Germany
关键词
implantable cardioverter defibrillator; inappropriate therapy; diaphragmatic myopotentials; oversensing;
D O I
10.1023/A:1013214516002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Nonadequate arrhythmia detection and delivery of electrical therapy is still a main problem in current implantable cardioverter defibrillator therapy. Besides supraventricular arrhythmias extracardiac biosignals also can cause inadequate shock delivery. The present study focuses on nonadequate arrhythmia detection due to oversensing of diaphragmatic myopotentials. Their clinical characteristics, incidence and management are presented. Threehundred-eighty-four recipients of a transvenous cardioverter-defibrillator who were implanted and followed-up at our institution between October 1991 and June 1999 were enrolled. During a mean follow-up of 32 +/- 25 months a total number of 139 nonadequate episodes of arrhythmia detection due to oversensing of diaphragmatic myopotentials were observed in 33 patients (8.6%). In 11 patients a total of 32 high energy shock deliveries occurred. Oversensing of diaphragmatic myopotentials was primarily observed in patients implanted with defibrillator leads providing "integrated bipolar" sensing. The vast majority of nonadequate arrhythmia detection were observed during intrinsic bradycardia heart rate and/or antibradycardia pacing. Electrical lead failure was ruled out in every patient. In 90% of the patients with a cardioverter-defibrillator providing programmable maximal sensitivity (n = 16), the reduction of maximum sensitivity was effective in preventing further episodes of nonadequate arrhythmia detection. In 48% of the patients with devices without programmable maximal sensitivity (n = 17), surgery revision was necessary to solve the problem.
引用
收藏
页码:487 / 493
页数:7
相关论文
共 21 条
[1]   Inappropriate shocks delivered by implantable cardiac defibrillators during oversensing of activity of diaphagmatic muscle [J].
Babuty, D ;
Fauchier, L ;
Cosnay, P .
HEART, 1999, 81 (01) :94-96
[2]   INHIBITION OF BIPOLAR DEMAND PACEMAKER BY DIAPHRAGMATIC MYOPOTENTIALS [J].
BAROLD, SS ;
ONG, LS ;
FALKOFF, MD ;
HEINLE, RA .
CIRCULATION, 1977, 56 (04) :679-683
[3]   MYOPOTENTIAL INHIBITION OF DEMAND PACEMAKERS - ETIOLOGIC, DIAGNOSTIC, AND THERAPEUTIC CONSIDERATIONS [J].
BERGER, R ;
JACOBS, W .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1979, 2 (06) :596-602
[4]   Myopotential sensing by a dual chamber implantable cardioverter defibrillator: Two case reports [J].
Deshmukh, P ;
Anderson, K .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (07) :767-772
[5]  
ELGAMAL M, 1979, PACE, V2, P191
[6]   THE CLINICAL INCIDENCE AND SIGNIFICANCE OF MYOPOTENTIAL SENSING WITH UNIPOLAR PACEMAKERS [J].
FETTER, J ;
BOBELDYK, GL ;
ENGMAN, FJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (05) :871-881
[7]  
Gregoratos G, 1998, J AM COLL CARDIOL, V31, P1175
[8]  
*GUID CORP, 1996, PHYS SYST MAN VENT A
[9]  
*GUID CORP, 1994, PHYS SYST MAN VENT P
[10]  
*GUID CORP, 1996, PHYS SYST MAN VENT M