Magnetic field exposures for UK live-line workers

被引:33
作者
Dawson, TW [1 ]
Caputa, K [1 ]
Stuchly, MA [1 ]
机构
[1] Univ Victoria, Dept Elect & Comp Engn, Victoria, BC V8W 3P6, Canada
关键词
D O I
10.1088/0031-9155/47/7/301
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dosimetry is evaluated for live-line workers exposed to 50 Hz non-uniform magnetic fields from typical high-voltage transmission lines in the United Kingdom. The configurations involve twin-, triple- and quadruple-conductor transmission line bundles. Scenarios include three worker postures for the twin and triple bundles, and four postures for the quadruple bundle. The postures are selected to simulate worst case scenarios representative of work practices and result in highest values of dosimetric measures in critical organs. Only single-phase bundles are considered, as adjacent bundles of differing phase result only in a small reduction of the dosimetric measures. Reported data include various measures of the electric field and current density induced in tissues, as well as of the current density averaged over I cm 2 areas normal to the current flow. A value of this latter quantity of 10 mA m(-2) is suggested as a threshold for neural tissue in the UK and international regulations. Critical tissues considered in this study include the retina, spinal cord, brain and cerebrospinal fluid. Some discussion is devoted to problems associated with the concept of current-density averaging, and two algorithms are considered. For a nominal load of 1 kA per subconductor, averaged current densities exceed the guideline bounds, only for a small number of postures and bundle configurations, in the brain, retina and cerebrospinal fluid. Non-averaged current densities in the cerebrospinal fluid exceed the suggested bound for all scenarios modelled, as well as in the retina for three postures involving a quadruple bundle.
引用
收藏
页码:995 / 1012
页数:18
相关论文
共 12 条
[1]  
Ahlbom A, 1998, HEALTH PHYS, V74, P494
[2]  
Dawson T. W., 2001, Applied Computational Electromagnetics Society Journal, V16, P162
[3]   High-resolution organ dosimetry for human exposure to low-frequency magnetic fields [J].
Dawson, TW ;
Stuchly, MA .
IEEE TRANSACTIONS ON MAGNETICS, 1998, 34 (03) :708-718
[4]   High-resolution magnetic field numerical dosimetry for live-line workers [J].
Dawson, TW ;
Caputa, K ;
Stuchly, MA .
IEEE TRANSACTIONS ON MAGNETICS, 1999, 35 (03) :1131-1134
[5]   Organ dosimetry for human exposure to non-uniform 60-Hz magnetic fields [J].
Dawson, TW ;
Caputa, K ;
Stuchly, MA .
IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (04) :1234-1239
[6]   A comparison of 60 Hz uniform magnetic and electric induction in the human body [J].
Dawson, TW ;
Caputa, K ;
Stuchly, MA .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (12) :2319-2329
[7]  
Kavet R, 2001, Appl Occup Environ Hyg, V16, P1118, DOI 10.1080/104732201753339622
[8]  
*NIEHS, 1998, NIH PUBL
[9]  
*NRPB, 1993, NRPB, V4, P8
[10]  
REILLY J. P., 1992, ELECT STIMULATION EL