Contrast media clearance in a single kidney measured on multiphasic helical CT: Results in 50 patients without acute renal disorder

被引:22
作者
Hackstein, N [1 ]
Gengiz, H [1 ]
Rau, WS [1 ]
机构
[1] Univ Giessen, Dept Diagnost Radiol, D-35385 Giessen, Germany
关键词
D O I
10.2214/ajr.178.1.1780111
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Single kidney contrast media clearance was measured using multiphasic CT in patients without acute renal disorder. The aim of this study was to answer two questions. First, how accurate is CT in measuring contrast media clearance compared with plasma clearance? Second, is the accuracy of CT clearance measurements dependent on the timing of CT scans with respect to the contrast media injection? SUBJECTS AND METHODS. Fifty adult patients without acute renal disorder were included in this study. Each patient underwent CT for clinical indications. The CT protocol consisted of an unenhanced scan and three contrast-enhanced scans 45, 75, and 105 see after starting an injection of 120 mL of iopromide using an injection rate of 3 mL/sec. All scans included both kidneys. As a reference, plasma clearance of contrast media was determined as a slope clearance by measuring iodine concentration in eight blood specimens up to 8 fir postinjection. RESULTS. CT clearance was calculated three times for each patient, including early CT clearance, 45-75 see postinjection; late CT clearance, 75-105 see postinjection; and overall CT clearance, 45-105 see postinjection. An overall CT clearance yielded the best correlation with plasma clearance with a correlation coefficient of r = 0.84 and a regression line of y = 7.5 + 0.94x. The mean difference was -3 mL/min (95% confidence interval, -35 to 29 mL/min). CONCLUSION. CT clearance calculated from data acquired with a minimally modified diagnostic abdominal CT protocol was well correlated with the reference method in determining contrast media clearance for patients without acute renal disorders. The presented method can be used to calculate single kidney contrast media clearance in patients receiving contrast-enhanced abdominal CT for clinical indications.
引用
收藏
页码:111 / 118
页数:8
相关论文
共 22 条
[1]  
Becker CR, 1998, RADIOLOGE, V38, P726, DOI 10.1007/s001170050416
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   The quantification of renal function with enhanced computed tomography [J].
Blomley, MJK ;
Dawson, P .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (827) :989-995
[4]   CONTRAST BOLUS DYNAMIC COMPUTED-TOMOGRAPHY FOR THE MEASUREMENT OF SOLID-ORGAN PERFUSION [J].
BLOMLEY, MJK ;
COULDEN, R ;
BUFKIN, C ;
LIPTON, MJ ;
DAWSON, P .
INVESTIGATIVE RADIOLOGY, 1993, 28 :S72-S77
[5]  
BODEMANN HH, 1995, LABOR DIAGNOSE, P594
[6]   ACUTE-RENAL-FAILURE IN MAN - NEW ASPECTS CONCERNING PATHOGENESIS - A MORPHOMETRIC STUDY [J].
BOHLE, A ;
CHRISTENSEN, J ;
KOKOT, F ;
OSSWALD, H ;
SCHUBERT, B ;
KENDZIORRA, H ;
PRESSLER, H ;
MARCOVICLIPKOVSKI, J .
AMERICAN JOURNAL OF NEPHROLOGY, 1990, 10 (05) :374-388
[7]  
DAWSON P, 1993, INVEST RADIOL, V28, pS79
[8]   DYNAMIC CONTRAST BOLUS COMPUTED-TOMOGRAPHY FOR THE ASSESSMENT OF RENAL-FUNCTION [J].
DAWSON, P ;
PETERS, M .
INVESTIGATIVE RADIOLOGY, 1993, 28 (11) :1039-1042
[9]  
DROSTE C, 1989, MEMORIX, P68
[10]   Measurement of single kidney contrast media clearance by multiphasic spiral computed tomography: preliminary results [J].
Hackstein, N ;
Puille, MF ;
Bak, BH ;
Scharwat, O ;
Rau, WS .
EUROPEAN JOURNAL OF RADIOLOGY, 2001, 39 (03) :201-208