Particle flow assays for fluorescent protein microarray applications

被引:7
作者
Bally, Marta
Dhumpa, Raghuram
Voeroes, Janos [1 ]
机构
[1] ETH, Inst Biomed Engn, Lab Biosensors & Bioelect, Zurich, Switzerland
关键词
Protein microarray; Reverse phase array; Microparticle label; Fluorescent signal amplification; Fluidic forces; Continuous flow assay; FORCE MEASUREMENTS; GENE-EXPRESSION; BINDING; NANOPARTICLES; DETACHMENT; MODEL;
D O I
10.1016/j.bios.2008.07.005
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Microarray technology has brought a paradigmatic change in bioanalytics. However, highly sensitive and accurate assays are still needed for a real breakthrough. We present a simple and generic approach for fluorescent signal amplification with fluorescent microparticle labels. The assay principle was demonstrated using a reverse array model consisting of spots of bovine serum albumin with a small fraction of the proteins biotinylated. Specific binding of streptavidin coated fluorescent microparticles to the spots was promoted by applying a controlled continuous microparticle flow. The surface bound beads were visualized and quantified with confocal microscopy images. Comparison with standard fluorescent and flow discrimination assays has revealed several advantages of our approach. First, non-specific particle binding could be reduced to less than I particle/spot making therefore the visualization of single biomolecular bonds possible. Second, the amplification scheme presented here is generic and can be applied to any fluorescent microarray. Furthermore, this assay makes use of a biotin-streptavidin linkage and can therefore be applied to all kind of assays. Finally, single fluorescent microbeads can be easily visualized with standard optical equipments, so that no high performance equipment is required. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1195 / 1200
页数:6
相关论文
共 51 条
[1]   In situ observation of streptavidin-biotin binding on an immunoassay well surface using an atomic force microscope [J].
Allen, S ;
Davies, J ;
Dawkes, AC ;
Davies, MC ;
Edwards, JC ;
Parker, MC ;
Roberts, CJ ;
Sefton, J ;
Tendler, SJB ;
Williams, PM .
FEBS LETTERS, 1996, 390 (02) :161-164
[2]   Surface attachment of nanoparticles using oligonucleotides [J].
Andersson, M ;
Elihn, K ;
Fromell, K ;
Caldwell, KD .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2004, 34 (03) :165-171
[3]   Optical microarray biosensing techniques [J].
Bally, Marta ;
Halter, Martin ;
Voeroes, Janos ;
Grandin, H. Michelle .
SURFACE AND INTERFACE ANALYSIS, 2006, 38 (11) :1442-1458
[4]   Influence of direction and type of applied force on the detachment of macromolecularly-bound particles from surfaces [J].
Chang, KC ;
Hammer, DA .
LANGMUIR, 1996, 12 (09) :2271-2282
[5]  
Charboneau Lu, 2002, Briefings in Functional Genomics & Proteomics, V1, P305, DOI 10.1093/bfgp/1.3.305
[6]   The relationship between ligand-binding thermodynamics and protein-ligand interaction forces measured by atomic force microscopy [J].
Chilkoti, A ;
Boland, T ;
Ratner, BD ;
Stayton, PS .
BIOPHYSICAL JOURNAL, 1995, 69 (05) :2125-2130
[7]   RECEPTOR-MEDIATED ADHESION PHENOMENA - MODEL STUDIES WITH THE RADIAL-FLOW DETACHMENT ASSAY [J].
COZENSROBERTS, C ;
QUINN, JA ;
LAUFFENBURGER, DA .
BIOPHYSICAL JOURNAL, 1990, 58 (01) :107-125
[8]   Specific antigen/antibody interactions measured by force microscopy [J].
Dammer, U ;
Hegner, M ;
Anselmetti, D ;
Wagner, P ;
Dreier, M ;
Huber, W ;
Guntherodt, HJ .
BIOPHYSICAL JOURNAL, 1996, 70 (05) :2437-2441
[9]   DNA microarrays in drug discovery and development [J].
Debouck, C ;
Goodfellow, PN .
NATURE GENETICS, 1999, 21 (Suppl 1) :48-50
[10]   Exploring the metabolic and genetic control of gene expression on a genomic scale [J].
DeRisi, JL ;
Iyer, VR ;
Brown, PO .
SCIENCE, 1997, 278 (5338) :680-686