Fault-Tolerant PMSG Drive With Reduced DC-Link Ratings for Wind Turbine Applications

被引:57
作者
Freire, Nuno M. A. [1 ]
Marques Cardoso, Antonio J. [2 ]
机构
[1] Univ Coimbra, Dept Elect & Comp Engn, P-3030290 Coimbra, Portugal
[2] Univ Beira Interior, Electromechatron Syst Res Ctr, P-6201001 Convento De Santo Antoni, Covilha, Portugal
关键词
Fault diagnosis; fault-tolerant systems; permanent magnet machines; semiconductor device reliability; wind power generation; MOTOR-DRIVES; RELIABILITY; STRATEGY; FREQUENCY; RECTIFIER; CONVERTER; DIAGNOSIS; SYSTEM;
D O I
10.1109/JESTPE.2013.2295061
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
080906 [电磁信息功能材料与结构]; 082806 [农业信息与电气工程];
摘要
Fault-tolerant permanent magnet synchronous generator drives might play an important role in improving the reliability and availability levels of the modern wind turbines. However, the acceptance by the wind turbine industry will be low if its implementation cannot be accomplished in a cost-effective way. In this paper, a low-cost fully integrated fault-tolerant converter with the ability to handle power switch open-circuit faults is proposed. The two topologies proposed for post-fault operation of the grid- and PMSG-side converters are a five-leg converter with a shared leg connected to a phase of the generator and to the transformer neutral point and a three-switch three-phase rectifier, respectively. Both do not require the oversizing of any component of the conventional system in order to operate within a limited range. Moreover, the fault diagnostic technique does not require additional measurements, and the integration into the drive controller of all diagnostic and control algorithms can be performed without great increase of the computational effort. Control strategies are proposed for the considered converter topologies, and their performance is analyzed by means of experimental results.
引用
收藏
页码:26 / 34
页数:9
相关论文
共 33 条
[1]
Experimental fault-tolerant control of a PMSM drive [J].
Bolognani, S ;
Zordan, M ;
Zigliotto, M .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2000, 47 (05) :1134-1141
[2]
Control implementation of a five-leg AC-AC converter to supply a three-phase induction machine [J].
Bouscayrol, A ;
Francois, B ;
Delarue, P ;
Niiranen, J .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (01) :107-115
[3]
Buja G. S., 2004, IEEE T IND ELECTRON, V51, P1973
[4]
A general PWM strategy for four-switch three-phase inverters [J].
Correa, Mauricio Beltrao de Rossiter ;
Jacobina, Cursino Brandao ;
da Silva, Edison Roberto Cabral ;
Nogueira Lima, Antonio Marcus .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2006, 21 (06) :1618-1627
[5]
Fault-Tolerant Voltage Source Inverter for Permanent Magnet Drives [J].
Errabelli, Rammohan Rao ;
Mutschler, Peter .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (02) :500-508
[6]
Estima J. O., 2013, 2013 IEEE Workshop on Electrical Machines Design, Control and Diagnosis (WEMDCD 2013). Proceedings, P279, DOI 10.1109/WEMDCD.2013.6525187
[7]
A New Algorithm for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Fed PWM Motor Drives by the Reference Current Errors [J].
Estima, Jorge O. ;
Marques Cardoso, Antonio J. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (08) :3496-3505
[8]
A New Approach for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Source Inverters [J].
Estima, Jorge O. ;
Marques Cardoso, Antonio J. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2011, 47 (06) :2487-2494
[9]
Fischer K., 2012, EM TECHN FACT AUT ET, P1
[10]
Freire N., 2013, IEEE T IND ELECT