Hydrogen/deuterium exchange for higher specificity of protein identification by peptide mass fingerprinting

被引:13
作者
Bienvenut, WV
Hoogland, C
Greco, A
Heller, M
Gasteiger, E
Appel, RD
Diaz, JJ
Sanchez, JC
Hochstrasser, DF
机构
[1] Univ Hosp Geneva, Cent Lab Clin Chem, CH-1211 Geneva 14, Switzerland
[2] Univ Geneva, Med Ctr, Swiss Inst Bioinformat, CH-1211 Geneva 4, Switzerland
[3] Fac Med Lyon, RTH Laennec, INSERM U369, F-69372 Lyon 08, France
[4] GeneProt Inc, CH-1217 Meyrin, Switzerland
关键词
D O I
10.1002/rcm.616
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Genome sequencing projects produce large amounts of information that could be translated into potential protein sequences. Such amounts of material continuously increase protein database sizes. At present, 991 times more protein sequences are available in the SWISS-PROT and TrEMBL databases than 8 years ago in SWISS-PROT. One of the methods of choice for protein identification makes use of specific endoproteolytic cleavage followed by matrix-assisted laser desorption/ ionisation mass spectrometric (MALDI-MS) analysis of the digested product. Since 1993, when this technique was first demonstrated., the conditions required for a correct identification have changed dramatically. Whilst 4-5 peptides with an uncertainty of 2-3 Da were sufficient for a correct identification in 1993,10-13 peptides with less than 60 ppm mass error are now required for human and E coli proteins. This evolution is directly related to the continuous increase in protein database sizes, which causes an increase in the number of false positive matches in identification results. Use of an information complement deduced from the primary protein sequence, in the process of identification by peptide mass fingerprints, can help to increase confidence in the identification results. In this article, we propose the exchange of labile hydrogen atoms with deuterium atoms to provide an alternative information complement. The exchange reaction with optimised techniques has shown an average 95% of hydrogen/denterium (H/D) exchange on tryptic peptides. This level of exchange was sufficient to single out one or more peptides from a list of potential candidate proteins due to the dependence of H/D exchange on the peptide primary structure. This technique also has clear advantages in the identification of small proteins where direct protein identification is impaired by the limited number of endoproteolytic peptides. Then, information related to primary sequence obtained with this technique could help to identify proteins with high confidence without any expensive tandem mass spectrometry instruments. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:616 / 626
页数:11
相关论文
共 59 条
[1]  
ACHARYA AS, 1977, INT J PEPT PROT RES, V9, P213
[2]   The genome sequence of Drosophila melanogaster [J].
Adams, MD ;
Celniker, SE ;
Holt, RA ;
Evans, CA ;
Gocayne, JD ;
Amanatides, PG ;
Scherer, SE ;
Li, PW ;
Hoskins, RA ;
Galle, RF ;
George, RA ;
Lewis, SE ;
Richards, S ;
Ashburner, M ;
Henderson, SN ;
Sutton, GG ;
Wortman, JR ;
Yandell, MD ;
Zhang, Q ;
Chen, LX ;
Brandon, RC ;
Rogers, YHC ;
Blazej, RG ;
Champe, M ;
Pfeiffer, BD ;
Wan, KH ;
Doyle, C ;
Baxter, EG ;
Helt, G ;
Nelson, CR ;
Miklos, GLG ;
Abril, JF ;
Agbayani, A ;
An, HJ ;
Andrews-Pfannkoch, C ;
Baldwin, D ;
Ballew, RM ;
Basu, A ;
Baxendale, J ;
Bayraktaroglu, L ;
Beasley, EM ;
Beeson, KY ;
Benos, PV ;
Berman, BP ;
Bhandari, D ;
Bolshakov, S ;
Borkova, D ;
Botchan, MR ;
Bouck, J ;
Brokstein, P .
SCIENCE, 2000, 287 (5461) :2185-2195
[3]  
AXELSSON J, 2001, C BIOL PATHOLOGY PRO
[4]   The SWISS-PROT protein sequence database and its supplement TrEMBL in 2000 [J].
Bairoch, A ;
Apweiler, R .
NUCLEIC ACIDS RESEARCH, 2000, 28 (01) :45-48
[5]   PEPTIDE LADDER SEQUENCING BY MASS-SPECTROMETRY USING A NOVEL, VOLATILE DEGRADATION REAGENT [J].
BARTLETJONES, M ;
JEFFERY, WA ;
HANSEN, HF ;
PAPPIN, DJC .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (09) :737-742
[6]  
BIENVENUT W, UNPUB
[7]   Toward a clinical molecular scanner for proteome research: Parallel protein chemical processing before and during western blot [J].
Bienvenut, WV ;
Sanchez, JC ;
Karmime, A ;
Rouge, V ;
Rose, K ;
Binz, PA ;
Hochstrasser, DF .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4800-4807
[8]   The complete genome sequence of Escherichia coli K-12 [J].
Blattner, FR ;
Plunkett, G ;
Bloch, CA ;
Perna, NT ;
Burland, V ;
Riley, M ;
ColladoVides, J ;
Glasner, JD ;
Rode, CK ;
Mayhew, GF ;
Gregor, J ;
Davis, NW ;
Kirkpatrick, HA ;
Goeden, MA ;
Rose, DJ ;
Mau, B ;
Shao, Y .
SCIENCE, 1997, 277 (5331) :1453-+
[9]   MASS RESOLUTION IMPROVEMENT BY INCORPORATION OF PULSED ION EXTRACTION IN A MATRIX-ASSISTED LASER-DESORPTION IONIZATION LINEAR TIME-OF-FLIGHT MASS-SPECTROMETER [J].
BROWN, RS ;
LENNON, JJ .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :1998-2003
[10]   Genome sequence of the nematode C-elegans:: A platform for investigating biology [J].
不详 .
SCIENCE, 1998, 282 (5396) :2012-2018