VALIDATION OF A METHOD TO ASSESS RANGE OF MOTION OF THE CERVICAL SPINE USING A TAPE MEASURE

被引:18
作者
Asha, Stephen E. [1 ,2 ]
Pryor, Richard [1 ]
机构
[1] St George Hosp, Emergency Dept, Kogarah, NSW 2217, Australia
[2] Univ New S Wales, Fac Med, Kensington, NSW 2033, Australia
关键词
Arthrometry; Articular; Range of Motion; Neck; Cervical; Reproducibility of Results; VALIDITY; RELIABILITY; GONIOMETER; FLEXION; DEVICE;
D O I
10.1016/j.jmpt.2013.07.005
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
100404 [儿少卫生与妇幼保健学];
摘要
Objective: The purposes of this study were to validate a tape measure method for measuring cervical spine range of motion compared with a universal goniometer in all planes of motion and to derive equations to convert a linear measurement to an angular distance. Methods: Participants were healthy volunteers. Measurements of flexion/extension, rotation, and lateral flexion were made with the universal goniometer and tape measure, in the neutral position, extreme of motion, and 2 positions between. Measurements from the 2 techniques were compared with Pearson correlation coefficient and simple linear regression to determine R-2, the regression coefficient and the regression equation. Reliability was assessed using the intraclass correlation coefficient. Results: There were 40 participants with a mean age of 30.5 (SD, 9.1) years. Goniometer measurements had good to excellent correlation with both absolute and percentage change in tape measurement (correlation coefficients, 0.74-0.94 and 0.75-0.91, respectively). Correlation was highest for flexion and extension, lowest for rotation and lateral flexion. The amount of variability in the data explained by the linear regression models (R-2) varied from 55% to 89%. Intraclass correlation coefficient ranged from 0.44 to 0.69 and 0.38 to 0.59 for intrarater and interrater reliability, respectively. Reliability was greatest for flexion and extension, lowest for rotation and lateral flexion. Conclusion: This study demonstrated that tape measurements correlated well with a universal goniometer. The tape measure may be useful for measuring cervical spine range of motion where availability, simplicity, and low cost are important considerations such as with conduct of research or patient management.
引用
收藏
页码:538 / 545
页数:8
相关论文
共 13 条
[1]
Antonaci F, 2000, CLIN EXP RHEUMATOL, V18, pS45
[2]
THE INFLUENCE OF BODY-SIZE ON LINEAR MEASUREMENTS USED TO REFLECT CERVICAL RANGE OF MOTION [J].
CHIBNALL, JT ;
DUCKRO, PN ;
BAUMER, K .
PHYSICAL THERAPY, 1994, 74 (12) :1134-1137
[3]
DAWSONSAUNDERS B, 1994, BASIC CLIN BIOSTATIS, P54
[4]
Hsieh C Y, 1986, J Orthop Sports Phys Ther, V8, P88
[5]
Maksymowych WP, 2006, J RHEUMATOL, V33, P2242
[6]
Cervical sagittal range-of-motion analysis using three methods - Cervical range-of-motion device, 3Space, and radiography [J].
Ordway, NR ;
Seymour, R ;
Donelson, RG ;
Hojnowski, L ;
Lee, E ;
Edwards, WT .
SPINE, 1997, 22 (05) :501-508
[7]
Cervical motion testing: Methodology and clinical implications [J].
Prushansky, Tamara ;
Dvir, Zeevi .
JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2008, 31 (07) :503-508
[8]
Validity study for the cervical range of motion device used for lateral flexion in patients with neck pain [J].
Tousignant, M ;
Duclos, E ;
Laflèche, S ;
Mayer, A ;
Tousignant-Laflamme, Y ;
Brosseau, L ;
O'Sullivan, JP .
SPINE, 2002, 27 (08) :812-817
[9]
Criterion validity of the cervical range of motion (CROM) goniometer for cervical flexion and extension [J].
Tousignant, M ;
de Bellefeuille, L ;
O'Donoughue, S ;
Grahovac, S .
SPINE, 2000, 25 (03) :324-330
[10]
Comparison of Methods of Measuring Active Cervical Range of Motion [J].
Whitcroft, Katherine L. ;
Massouh, Laura ;
Amirfeyz, Rouin ;
Bannister, Gordon .
SPINE, 2010, 35 (19) :E976-E980