Synthesis and characterization of magnetic metal-organic framework (MOF) as a novel sorbent, and its optimization by experimental design methodology for determination of palladium in environmental samples

被引:150
作者
Bagheri, Akbar [1 ]
Taghizadeh, Mohsen [1 ]
Behbahani, Mohammad [1 ]
Asgharinezhad, Ali Akbar [1 ]
Salarian, Mani [1 ]
Dehghani, Ali [1 ,2 ]
Ebrahimzadeh, Homeira [1 ]
Amini, Mostafa M. [1 ]
机构
[1] Shahid Beheshti Univ, Dept Chem, Tehran, Iran
[2] Iran Univ Sci & Technol, Fac Chem, Tehran 16846, Iran
关键词
Magnetic metal-organic frame work; Palladium; Preconcentration; Box-Behnken design; Flame atomic absorption spectrometry; ATOMIC-ABSORPTION-SPECTROMETRY; LIQUID-LIQUID MICROEXTRACTION; ICP-AES DETERMINATION; SPECTROPHOTOMETRIC DETERMINATION; ONLINE PRECONCENTRATION; GEOLOGICAL SAMPLES; PRECIOUS METALS; SEPARATION; PLATINUM; GOLD;
D O I
10.1016/j.talanta.2012.05.030
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
This paper describes the synthesis and application of novel magnetic metal-organic framework (MOF) [(Fe3O4-Pyridine)/Cu-3(BTC)(2)] for preconcentration of Pd(II) and its determination by flame atomic absorption spectrometry (FAAS). A Box-Behnken design was used to find the optimum conditions for the preconcentration procedure through response surface methodology. Three variables including amount of magnetic MOF, extraction time, and pH of extraction were selected as factors for adsorption step, and in desorption step, four parameters including type, volume, and concentration of eluent, and desorption time were selected in the optimization study. These values were 30 mg, 6 min, 6.9, K2SO4+ NaOH, 6 mL, 9.5 (w/v %) + 0.01 mol L-1, 15.5 min, for amount of MOF, extraction time, pH of extraction, type, volume, and concentration of the eluent, and desorption time, respectively. The preconcentration factor (PF), relative standard deviation (RSD), limit of detection (LOD), and adsorption capacity of the method were found to be 208, 2.1%, 0.37 ng mL(-1), and 105.1 mg g(-1), respectively. It was found that the magnetic MOF has more capacity compared to Fe3O4-Py. Finally, the magnetic MOF was successfully applied for rapid extraction of trace amounts of Pd (II) ions in fish, sediment, soil, and water samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:132 / 139
页数:8
相关论文
共 46 条
[1]
Stopped-flow injection liquid-liquid extraction spectrophotometric determination of palladium in airborne particulate matter and automobile catalysts [J].
Anthemidis, AN ;
Themelis, DG ;
Stratis, JA .
TALANTA, 2001, 54 (01) :37-43
[3]
Cloud-point extraction for the determination of Cd, Pb and Pd in blood by electrothermal atomic absorption spectrometry, using Ir or Ru as permanent modifiers [J].
Borges, DLG ;
da Veiga, MAMS ;
Frescura, VLA ;
Welz, B ;
Curtius, AJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (05) :501-507
[4]
Box GEP, 1987, Empirical model-building and response surfaces
[5]
Preconcentration of traces of gold, silver and palladium on activated carbon and its determination in geological samples by flame AAS after wet ashing [J].
Chakrapani, G ;
Mahanta, PL ;
Murty, DSR ;
Gomathy, B .
TALANTA, 2001, 53 (06) :1139-1147
[6]
Determination of platinum and palladium in environmental samples by graphite furnace atomic absorption spectrometry after separation on dithizone sorbent [J].
Chwastowska, J ;
Skwara, W ;
Sterlinska, E ;
Pszonicki, L .
TALANTA, 2004, 64 (01) :224-229
[7]
Synthesis of imprinted polymer material with palladium ion nanopores and its analytical application [J].
Daniel, S ;
Gladis, JM ;
Rao, TP .
ANALYTICA CHIMICA ACTA, 2003, 488 (02) :173-182
[8]
Hydrogen storage in microporous metal-organic frameworks with exposed metal sites [J].
Dinca, Mircea ;
Long, Jeffrey R. .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2008, 47 (36) :6766-6779
[9]
New poly (N-(hydroxymethyl)methacrylamide-1-allyl-2-thiourea) hydrogels prepared by radiation-induced polymerisation:: Selective adsorption, recovery and pre-concentration of Pt(II) and Pd(II) [J].
Döker, S ;
Malci, S ;
Dogan, M ;
Salih, B .
ANALYTICA CHIMICA ACTA, 2005, 553 (1-2) :73-82
[10]
Impact of selective antimicrobial agents on staphylococcal adherence to biomedical devices [J].
Edmiston, Charles E., Jr. ;
Goheen, Michael P. ;
Seabrook, Gary R. ;
Johnson, Christopher P. ;
Lewis, Brian D. ;
Brown, Kellie R. ;
Towne, Jonathan B. .
AMERICAN JOURNAL OF SURGERY, 2006, 192 (03) :344-354