Ultrasound enhanced anodic stripping voltammetry using perfluorosulfonated ionomer-coated mercury thin-film electrodes

被引:86
作者
Matysik, FM [1 ]
Matysik, S [1 ]
Brett, AMO [1 ]
Brett, CMA [1 ]
机构
[1] UNIV COIMBRA,DEPT QUIM,P-3049 COIMBRA,PORTUGAL
关键词
D O I
10.1021/ac960815j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The high mass transport caused by ultrasonic radiation in the preconcentration of trace metal species in anodic stripping voltammetry (ASV), leads to an order of magnitude enhancement in sensitivity. A Non-coated mercury thin-film working electrode is placed in a specially designed small-volume sonovoltammetric cell. The preparation and curing procedure for the Nafion film on a glassy carbon electrode substrate as well as ultrasound enhanced mercury deposition through the Nafion him are optimized. The resulting electrode assembly is stable under ultrasonic irradiation. Optical microscopy observations show the formation of closely spaced mercury droplets of micrometer dimensions under the Nafion film. The performance characteristics of ultrasound-enhanced ASV at the Nafion-coated mercury thin-film electrode are studied in detail. The detection limit obtained for lead and cadmium test species is 3 x 10(-11) M (30 s preconcentration in the presence of ultrasound). A relative standard deviation of 1.2% is obtained for repetitive determinations of 10 nM Cd2+ (n = 9).
引用
收藏
页码:1651 / 1656
页数:6
相关论文
共 25 条
[1]  
BRETT AMO, IN PRESS ELECTROCHIM
[2]  
BRETT AMO, IN PRESS BIOELECTROC
[3]   SQUARE-WAVE ANODIC-STRIPPING VOLTAMMETRY IN STATIONARY AND FLOWING SOLUTION - A COMPARATIVE-STUDY [J].
BRETT, CMA ;
LIMA, JLFC ;
GARCIA, MBQ .
ANALYST, 1994, 119 (06) :1229-1233
[4]  
BRETT CMA, 1996, TALANTA, V42, P2015
[5]   DETERMINATION OF TRACES OF METALS BY ANODIC-STRIPPING VOLTAMMETRY AT A ROTATING GLASSY-CARBON RING-DISC ELECTRODE .1. METHOD AND INSTRUMENTATION WITH EVALUATION OF SOME PARAMETERS [J].
BRIHAYE, C ;
DUYCKAERTS, G .
ANALYTICA CHIMICA ACTA, 1982, 143 (01) :111-120
[6]   VOLTAMMETRY IN THE PRESENCE OF ULTRASOUND - SONOVOLTAMMETRY AND SURFACE EFFECTS [J].
COMPTON, RG ;
EKLUND, JC ;
PAGE, SD ;
SANDERS, GHW ;
BOOTH, J .
JOURNAL OF PHYSICAL CHEMISTRY, 1994, 98 (47) :12410-12414
[7]   SONOVOLTAMMETRY - HETEROGENEOUS ELECTRON-TRANSFER PROCESSES WITH COUPLED ULTRASONICALLY INDUCED CHEMICAL-REACTION - THE SONO-EC REACTION [J].
COMPTON, RG ;
EKLUND, JC ;
PAGE, SD .
JOURNAL OF PHYSICAL CHEMISTRY, 1995, 99 (12) :4211-4214
[8]   Sonovoltammetric behavior of ascorbic acid and dehydroascorbic acid at glassy carbon electrodes: Analysis using pulsed sonovoltammetry [J].
Compton, RG ;
Matysik, FM .
ELECTROANALYSIS, 1996, 8 (03) :218-222
[9]   COMPARATIVE-STUDY OF POLYMER-COATED MERCURY FILM ELECTRODES FOR VOLTAMMETRIC ANALYSIS OF LEAD AND CADMIUM IN THE PRESENCE OF SURFACTANTS [J].
DAM, MER ;
THOMSEN, KN ;
PICKUP, PG ;
SCHRODER, KH .
ELECTROANALYSIS, 1995, 7 (01) :70-78
[10]   DETERMINATION OF IRON BY ANODIC STRIPPING VOLTAMMETRY [J].
FLORENCE, TM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1970, 26 (2-3) :293-&