Sensitivity of laparoscopic dissectors - What can you feel?

被引:60
作者
den Boer, KT [1 ]
Herder, JL [1 ]
Sjoerdsma, W [1 ]
Meijer, DW [1 ]
Gouma, DJ [1 ]
Stassen, HG [1 ]
机构
[1] Delft Univ Technol, Fac Design Engn & Prod, NL-2628 CD Delft, Netherlands
来源
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES | 1999年 / 13卷 / 09期
关键词
dissectors; feedback quality; laparoscopy; psychophysics; sensitivity;
D O I
10.1007/s004649901122
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Sensory feedback is reduced considerably in minimally invasive procedures by the interposition of instruments, causing loss of direct manual contact with the tissue. The purpose of this study was to evaluate the feedback quality of commercially available reusable and disposable laparoscopic dissectors. Methods: A total of 31 participants were asked to feel a simulated arterial pulse with their bare fingers and through laparoscopic dissectors, tweezers, an orthopedic forceps, and a laparoscopic low-friction prototype. The absolute sensory threshold was determined by the psychophysical method of limits. Results: The sensory feedback quality was significantly better for the reusable dissectors tested than for the disposable dissector (p < 0.001). Nevertheless, the reusable dissectors were at least eight times less sensitive than bare fingers. Furthermore, sensitivity qualities were highly variable, depending on the dissector tested. Conclusions: This study showed that the overall sensitivity loss through instruments could be accurately assessed, proving that the sensory feedback for commercially available instruments was low compared to bare fingers. The good sensory feedback results of the prototype indicated that careful design could decrease the overall sensitivity loss.
引用
收藏
页码:869 / 873
页数:5
相关论文
共 13 条
[1]   ELECTRONIC ENDOSCOPY - THE LATEST TECHNOLOGY [J].
CLASSEN, M ;
KNYRIM, K ;
SEIDLITZ, HK ;
HAGENMULLER, F .
ENDOSCOPY, 1987, 19 (03) :118-123
[2]  
Claus G P, 1995, Endosc Surg Allied Technol, V3, P210
[3]   WHITHER MINIMAL ACCESS SURGERY - TRIBULATIONS AND EXPECTATIONS [J].
CUSCHIERI, A .
AMERICAN JOURNAL OF SURGERY, 1995, 169 (01) :9-19
[4]  
Gescheider G., 1976, Psychophysics: Method and Theory
[5]  
GRIMBERGEN CA, 1997, MINIMALLY INVASIVE S, V18, P223
[6]   A laparoscopic grasper with force perception [J].
Herder, JL ;
Horward, MJ ;
Sjoerdsma, W .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1997, 6 (04) :279-286
[7]  
HERDER JL, 1997, MIN INVAS THER AL S1, V6, P55
[8]   PITFALLS OF MINIMALLY INVASIVE SURGERY (REPRINTED FROM DER CHIRURG, VOL 64, PG 211, 1993) [J].
HERFARTH, C ;
SCHUMPELICK, V ;
SIEWERT, JR .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 1994, 8 (08) :847-847
[9]  
JANSEN A, 1993, MINIMALLY INVASIVE S, P15
[10]  
Melzer A, 1992, OPERATIVE MANUAL END, P14