Bioelectromagnetic localization of a pacing catheter in the heart

被引:21
作者
Pesola, K
Nenonen, J
Fenici, R
Lötjönen, J
Mäkijärvi, M
Fenici, P
Korhonen, P
Lauerma, K
Valkonen, M
Toivonen, L
Katila, T
机构
[1] Helsinki Univ Technol, Biomed Engn Lab, Espoo 02015, Finland
[2] Univ Helsinki, Cent Hosp, Med Engn Ctr, BioMag Lab, FIN-00290 Helsinki, Finland
[3] Univ Cattolica Sacro Cuore, Clin Physiol Biomagnetism Ctr, I-00168 Rome, Italy
[4] Univ Helsinki, Cent Hosp, Dept Internal Med, Div Cardiol, FIN-00290 Helsinki, Finland
[5] Univ Helsinki, Cent Hosp, Dept Radiol, FIN-00290 Helsinki, Finland
关键词
D O I
10.1088/0031-9155/44/10/314
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The accuracy of localizing source currents within the human heart by non-invasive magneto- and electrocardiographic methods was investigated in 10 patients. A non-magnetic stimulation catheter inside the heart served as a reference current source. Biplane fluoroscopic imaging with lead bail markers was used to record the catheter position. Simultaneous multichannel magnetocardiographic (MCG) and body surface potential mapping (BSPM) recordings were performed during catheter pacing. Equivalent current dipole localizations were computed from MCG and BSPM data, employing standard and patient-specific boundary element torso models. Using individual models with the lungs included, the average MCG localization error was 7 +/- 3 mm, whereas the average BSPM localization error was 25 +/- 4 mm. In the simplified case of a single homogeneous standard torso model, an average error of 9 +/- 3 mm was obtained from MCG recordings. The MCG localization accuracies obtained in this study imply that the capability of multichannel MCG to locate dipolar sources is sufficient for clinical purposes, even without constructing individual torso models from x-ray or from magnetic resonance images.
引用
收藏
页码:2565 / 2578
页数:14
相关论文
共 41 条
[1]   BIOMAGNETIC LOCALIZATION OF ELECTRICAL-CURRENT SOURCES IN THE HUMAN HEART WITH REALISTIC VOLUME CONDUCTORS USING THE SINGLE-CURRENT-DIPOLE MODEL [J].
BRUDER, H ;
KILLMANN, R ;
MOSHAGE, W ;
WEISMULLER, P ;
ACHENBACH, S ;
BOMMEL, F .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (04) :655-668
[2]   THE INFLUENCE OF INHOMOGENEOUS VOLUME CONDUCTOR MODELS ON THE ECG AND THE MCG [J].
BRUDER, H ;
SCHOLZ, B ;
ABRAHAMFUCHS, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (11) :1949-1968
[3]   MAGNETIC-FIELD PRODUCED BY A CURRENT DIPOLE [J].
COHEN, D ;
HOSAKA, H .
JOURNAL OF ELECTROCARDIOLOGY, 1976, 9 (04) :409-417
[4]   A LINEAR DISCRETIZATION OF THE VOLUME CONDUCTOR BOUNDARY INTEGRAL-EQUATION USING ANALYTICALLY INTEGRATED ELEMENTS [J].
DEMUNCK, JC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (09) :986-990
[5]   PACE MAPPING USING BODY-SURFACE POTENTIAL MAPS TO GUIDE CATHETER ABLATION OF ACCESSORY PATHWAYS IN PATIENTS WITH WOLFF-PARKINSON-WHITE SYNDROME [J].
DUBUC, M ;
NADEAU, R ;
TREMBLAY, G ;
KUS, T ;
MOLIN, F ;
SAVARD, P .
CIRCULATION, 1993, 87 (01) :135-143
[6]   Magnetocardiographic pacemapping for nonfluoroscopic localization of intracardiac electrophysiology catheters [J].
Fenici, R ;
Pesola, K ;
Korhonen, P ;
Mäkijärvi, M ;
Nenonen, J ;
Toivonen, L ;
Fenici, P ;
Katila, T .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11) :2492-2499
[7]   Nonfluoroscopic localization of an amagnetic catheter in a realistic torso phantom by magnetocardiographic and body surface potential mapping [J].
Fenici, R ;
Pesola, K ;
Mäkijärvi, M ;
Nenonen, J ;
Teener, U ;
Fenici, P ;
Katila, T .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11) :2485-2491
[8]   MAGNETOCARDIOGRAPHY - VENTRICULAR ARRHYTHMIAS [J].
FENICI, R ;
MELILLO, G .
EUROPEAN HEART JOURNAL, 1993, 14 :53-60
[9]   Nonfluoroscopic localization of an amagnetic stimulation catheter by multichannel magnetocardiography [J].
Fenici, R ;
Nenonen, J ;
Pesola, K ;
Korhonen, P ;
Lötjönen, J ;
Mäkijärvi, M ;
Toivonen, L ;
Poutanen, VP ;
Keto, P ;
Katila, T .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (08) :1210-1220
[10]  
FENICI R, 1996, MICRO SYSTEM TECHNOL, P711